90 resultados para strength and function


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The test groups were experimental zirconia, Zirkonzahn zirconia, and Schuetz zirconia. Blocks of partially sintered zirconia were cut into disks (n=20) and then veneered with a feldspathic porcelain. Half of the specimens from each group (n=10) were incubated in 37°C water for 24 hours, and the other half were thermocycled. All the specimens were then subjected to shear testing. The fractured areas were analyzed with optical stereomicroscopy and classified as adhesive, cohesive, or an adhesive-cohesive failure. Spectral patterns were examined to detect bands related to the zirconia and feldspathic porcelain phases. The shear strength data were submitted to 2-way ANOVA. Results No significant differences in shear bond strength were observed among the 3 groups, regardless of whether or not the specimens were thermocycled. Adhesive failures were the most prevalent types of failure (70%). Raman spectra were clearly distinguished for all the materials, which showed the presence of tetragonal and monoclinic phases. Conclusions The controlled production of the experimental zirconia did not influence the results of the bond strength. Raman analysis suggested a process of interdiffusion by the presence of peaks associated with the zirconia and feldspathic ceramics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the most interesting alternatives for replacement of hard chrome plating is tungsten carbide thermal spray coating applied by the high velocity oxy-fuel (HVOF) process which presents a safer, cleaner and less expensive alternative to chromium plating. The objective of this research is to compare the influence of the tungsten carbide-17cobalt (WC- 17Co) coating applied by high velocity oxy fuel (HVOF) process with that of hard-chromium electroplating on the fatigue strength and abrasive wear of AISI 4340 steel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A anastomose arterial término-terminal é demorada, requer tempo prolongado de oclusão vascular e esta associada a necrose focal, infiltração leucocitária e, conseqüentemente, à fibrose e calcificação da parede arterial. A cola de fibrina é uma alternativa para a anastomose microvascular e pode evitar estas alterações com menor aderência aos tecidos vizinhos e melhor coaptação das bordas arteriais. OBJETIVO: Comparar o processo cicatricial de anastomoses convencionais com anastomoses feitas com cola de fibrina em artérias maiores. MÉTODOS: em 22 coelhos, ambas carótidas foram seccionadas transversalmente e reconstruídas por meio de anastomose término-terminal com 4 pontos simples de reparo e cola de fibrina de um lado (G1), e com 8 pontos separados do outro lado (G2). Após 3 e 15 dias, os animais foram destinados aleatoriamente para estudo de força tênsil concentração de hidroxiprolina (8 animais) e avaliação histológica das anastomoses (3 animais). As lâminas histológicas foram coradas pelo HE Masson e Picrossirius polarização (PSP). RESULTADOS: Após 3 e 15 dias a força tênsil aumenta em ambos os grupos, de 280,0± 32,6g para 432,2± 131,2g no Grupo 1 e de 221,4± 72,4g para 452,2± 132,0g no Grupo 2; sem diferença estatística entre os grupos em cada período. A concentração de hidroxiprolina expressa como razão hidroxiprolina/proteína, variou de 0,0816± 0,0651 para 0,0622± 0,0184 no Grupo 1 e de 0,0734± 0,0577 para 0,0460± 0,0271 no Grupo 2; sem diferença estatística entre os períodos e grupos. Os estudos histológicos mostraram discreto aumento das reações de inflamação e reparação no Grupo 2. A técnica PSP mostrou predomínio do colágeno tipo I em relação do colágeno tipo II nas anastomoses de ambos os grupos, sem diferença expressiva entre esses grupos. CONCLUSÃO: A anastomose com a cola de fibrina foi menos lesiva para a parede arterial do que a anastomose convencional. Mesmo usando menos pontos, as características de força tênsil e de cicatrização da anastomose com cola de fibrina foram similares em ambos os grupos. Os tempos de realização das anastomoses foram significativamente maiores do que na anastomose convencional.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

center dot Background and Aims Nectar production in the Bignoniaceae species lacking a nectariferous functional disc is ascribed to trichomatic glands around the ovary base and/or on the inner corolla wall. Nevertheless, knowledge about the secretion and function of these glands is very incomplete. The purpose of this paper is to study, from a developmental viewpoint, the ultrastructure, histochemistry and secretory process of the peltate trichomes on the ovary of Zeyheria montana, a species in the Bignoniaceae which has a rudimentary disc.center dot Methods Samples of the gynoecium at various developmental stages were fixed and processed for light and electron microscopy. Histochemistry and cytochemistry tests were performed to examine the chemical composition of exudates. Thin layer chromatography was used to determine the presence of alkaloids and terpenes in gynoecium and fruit extracts, and in fresh nectar stored in the nectar chamber.center dot Key Results Peltate trichomes at different developmental stages appear side by side from floral budding up to pre-dispersal fruit. Large plastids with an extensive internal membrane system consisting of tubules filled with lipophilic material, abundant smooth endoplasmic reticulum, few Golgi bodies, lipophilic deposits in the smooth endoplasmic reticulum and mitochondria, and scattered cytoplasmic oil droplets are the main characteristics of mature head cells. The secretion which accumulates in the subcuticular space stains positively for hydrophilic and lipophilic substances, with lipids prevailing for fully peltate trichomes. Histochemistry and thin layer chromatography detected terpenes and alkaloids. Fehling's test to detect of sugars in the secretion was negative.center dot Conclusions the continuous presence and activity of peltate trichomes on the ovary of Z. montana from early budding through to flowering and fruiting set, and its main chemical components, alkaloids and terpenes, suggest that they serve a protective function and are not related to the floral nectar source or to improving nectar quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the opaque layer firing temperature and mechanical and thermal cycling on the flexural strength of a ceramic fused to commercial cobalt-chromium alloy (Co-Cr). The hypotheses were that higher opaque layer temperatures increase the metal/ceramic bond strength and that aging reduces the bond strength.Materials and Methods: Metallic frameworks (25 x 3 x 0.5 mm(3); ISO 9693) (N = 60) were cast in Co-Cr and airborne-particle abraded (Al(2)O(3): 150 mu m) at the central area of the frameworks (8 x 3 mm(2)) and divided into three groups (N = 20), according to the opaque layer firing temperature: Gr1 (control)-900 degrees C; Gr2-950 degrees C; Gr3-1000 degrees C. The opaque ceramic (Opaque, Vita Zahnfabrick, Bad Sackingen, Germany) was applied, and the glass ceramic (Vita Omega 900, Vita Zahnfabrick) was fired onto it (thickness: 1 mm). While half the specimens from each group were randomly tested without aging (water storage: 37 degrees C/24 hours), the other half were mechanically loaded (20,000 cycles; 50 N load; distilled water at 37 degrees C) and thermocycled (3000 cycles; 5 degrees C to 55 degrees C, dwell time: 30 seconds). After the flexural strength test, failure types were noted. The data were analyzed using 2-way ANOVA and Tukey's test (alpha = 0.05).Results: Gr2 (19.41 +/- 5.5 N) and Gr3 (20.6 +/- 5 N) presented higher values than Gr1 (13.3 +/- 1.6 N) (p = 0.001). Mechanical and thermal cycling did not significantly influence the mean flexural strength values (p > 0.05). Increasing the opaque layer firing temperature improved the flexural bond strength values (p < 0.05). The hypotheses were partially accepted.Conclusion: Increasing of the opaque layer firing temperature improved the flexural bond strength between ceramic fused to Co-Cr alloy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: the purpose of the present study was to investigate the effects of ND:YLF laser irradiation (1.31 J/cm(2); 250 mJ per pulse), acid etching, and hypermineralization on the shear bond strength (SBS) of the Scotchbond Multi-Purpose Plus (3M Dental Products) bonding system. Summary Background Data: Previous studies had shown that the pretreatment of the dentin substrate with laser irradiation can influence the SBS, Methods: Sixty bovine incisors were selected and stored at -18 degrees C, Dentinal buccal surface was exposed and radiographs were taken to control dentin thickness, the specimens were separated into 2 groups: (1) the control, which was kept in distilled water at 4 degrees C; (2) the hypermineralized, which was kept in hypermineralizing solution at 4 degrees C for 14 days, Each group was divided into 3 subgroups according to the type of dentin pretreatment used: M (acid etching + primer + bond); AL (acid etching + primer + bond + laser); and LA (laser + acid etching + primer + bond). A standard composite resin cylinder (Z100-3M) was bonded to the dentinal surface and the SBS performed on an Instron machine (500 Kg load cell at 0.5 mm/min), followed by scanning electron microscopy (SEM) and x-ray diffraction analysis. Results: Analysis of variance (ANOVA) determined that the pretreatments influenced the SBS values (p < 0.05): AL (9.96 MPa), M (7.28 MPa), and LA (4.87 MPa), the interaction between the group and pretreatment factors also influenced the SBS (p < 0.05). The highest values were obtained for the interaction control/AL (11.64 MPa), Conclusion: the results suggested that dentin treatment with laser after the application of the adhesive system is efficient in achieving higher bond strength and is promising as a possible new adhesive substrate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A disfunção pulmonar no obeso pode estar associada a comprometimento muscular respiratório e também pode ser influenciada pelo predomínio de distribuição de gordura corporal na região toraco-abdominal. O objetivo foi avaliar a força dos músculos respiratórios em obesos e analisar a influência da distribuição do tecido adiposo. TIPO DE ESTUDO E LOCAL: Estudo transversal no período pré-operatório de Cirurgia Bariátrica. Estudo desenvolvido no Programa de Pós-Graduação em Bases Gerais da Cirurgia da Universidade Estadual Paulista (Unesp) - Faculdade de Medicina de Botucatu. MÉTODO: Mensuração da força dos músculos respiratórios através das medidas das pressões inspiratórias e expiratórias máximas (PImax e PEmax) em obesos candidatos à cirurgia bariátrica. Avaliar a distribuição do tecido adiposo através da relação entre as circunferências da cintura e quadril (RC/Q). Comparar esses atributos com os valores de referência de normalidade e também entre grupos com diferentes índices de massa corpórea (IMC). RESULTADOS: Foram avaliados 23 homens e 76 mulheres. Todos foram submetidos à avaliação de PImax e 86 realizaram a PEmax. O IMC médio foi de 44,42 kg/m². Os valores de PImax e de PEmax estavam dentro dos padrões de normalidade, a relação cintura-quadril mostrou distribuição do tecido adiposo na porção superior corporal e não houve correlação entre as variáveis estudadas. CONCLUSÃO: Na população de obesos estudada, o excesso de peso não provocou alterações na força dos músculos respiratórios, e as modificações não foram influenciadas pela distribuição de gordura predominante em porção superior corporal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The magnetic-field and confinement effects on the Land, factor in AlxGa1-xAs parabolic quantum wells under magnetic fields applied parallel or perpendicular to the growth direction are theoretically studied. Calculations are performed in the limit of low temperatures and low electron density in the heterostructure. The g factor is obtained by taking into account the effects of non-parabolicity and anisotropy of the conduction band through the 2 x 2 Ogg-McCombe Hamiltonian, and by including the cubic Dresselhaus spin-orbit term. A simple formula describing the magnetic-field dependence of the effective Land, factor is analytically derived by using the Rayleigh-Schrodinger perturbation theory, and it is found in good agreement with previous experimental studies devoted to understand the behavior of the g factor, as a function of an applied magnetic field, in semiconductor heterostructures. Present numerical results for the effective Land, factor are shown as functions of the quantum-well parameters and magnetic-field strength, and compared with available experimental measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Orofacial pain and pain in the muscles of mastication are frequent symptoms of temporomandibular disorder. The masseter is the closet masticatory muscle to the surface and has the function of raising and retracting the mandible. This muscle has considerable strength and is one of the main muscles involved in the shredding of food It is therefore of utmost importance in the masticatory cycle and generally the most affected by pain and spasms. Objectives: The aim of the present study was to analyze the effect of manual therapy with transversal and circular movements on pain and spasm in the masseter muscle, using electromyography and a visual analogue pain scale (VAPS). Eight women who experienced pain upon palpation of the masseter greater than 6 on the VAPS were selected for participation in the study, which employed electromyography and a VAPS for assessment, followed by manual oral physiotherapy and reevaluation. Results: The statistical analysis revealed a reduction in pain, but there was no significant difference in electromyographic activity (p < 0.05). Conclusion: It was concluded that massage therapy was effective on pain symptoms, but was not capable of altering the electrical activity of the masseter muscle.