135 resultados para strength and ductilities


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fiber reinforced epoxy composites are used in a wide variety of applications in the aerospace field. These materials have high specific moduli, high specific strength and their properties can be tailored to application requirements. In order to screening optimum materials behavior, the effects of external environments on the mechanical properties during usage must be clearly understood. The environmental action, such as high moisture concentration, high temperatures, corrosive fluids or ultraviolet radiation (UV), can affect the performance of advanced composites during service. These factors can limit the applications of composites by deteriorating the mechanical properties over a period of time. Properties determination is attributed to the chemical and/or physical damages caused in the polymer matrix, loss of adhesion of fiber/resin interface, and/or reduction of fiber strength and stiffness. The dynamic elastic properties are important characteristics of glass fiber reinforced composites (GRFC). They control the damping behavior of composite structures and are also an ideal tool for monitoring the development of GFRC's mechanical properties during their processing or service. One of the most used tests is the vibration damping. In this work, the measurement consisted of recording the vibration decay of a rectangular plate excited by a controlled mechanism to identify the elastic and damping properties of the material under test. The frequency amplitude were measured by accelerometers and calculated by using a digital method. The present studies have been performed to explore relations between the dynamic mechanical properties, damping test and the influence of high moisture concentration of glass fiber reinforced composites (plain weave). The results show that the E' decreased with the increase in the exposed time for glass fiber/epoxy composites specimens exposed at 80 degrees C and 90% RH. The E' values found were: 26.7, 26.7, 25.4, 24.7 and 24.7 GPa for 0, 15, 30, 45 and 60 days of exposure, respectively. (c) 2005 Springer Science + Business Media, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives. This study was undertaken to evaluate the shear bond strength of four materials used as aesthetic material bonded to Ni-Cr alloy.Methods. Sixty-eight alloy discs were prepared and divided equally into four groups, and received four treatments for veneering: conventional feldspathic porcelain (Noritake EX-3) and three light-cured prosthodontic composite resins (Artglass, Solidex and Targis). The aesthetic materials were applied after metal structure conditioning in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37 degreesC for 7 days. A universal testing machine was used to measure the shear bond strength of the specimens at a cross head speed of 0.5 mm/min. Fractured specimens were examined by using both optical and scanning electron microscope.Results. The analysis of variance and Tukey's test showed that the strongest mean shear bond was obtained with Noritake EX-3 (mean shear bond strength 42.90 +/- 7.82 MPa). For composites, the highest mean shear bond strength was observed for Targis (12.30 +/- 1.57 MPa); followed by Solidex (11.94 +/- 1.04 MPa) and Artglass (10.04 +/- 0.75 MPa). Optical analysis of the fractured surf aces indicated that for Targis and Noritake EX-3 all failures were a mixture of both cohesive and adhesive patterns. As for Artglass and Solidex, the fractures were mainly adhesive in nature.Conclusions. The Solidex system was equivalent to the Targis system in bond strength and exhibited greater strength than the Artglass system. The porcelain fused-to-metal showed considerably higher shear bond strength than the three metal-resin bonding techniques. (C) 2003 Elsevier B.V. Ltd. Ali rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the fracture strength and failure mode of flared bovine roots restored with different intraradicular posts. Material and Methods: Fifty bovine incisors with similar dimensions were selected and their roots were flared until 1.0 mm of dentin wall remained. Next, the roots were allocated into five groups (n=10): GI-cast metal post-and-core; GII-fiber posts plus accessory fiber posts; GIII-direct anatomic post; GIV-indirect anatomic post and GV-control (specimens without intraradicular post). A polyether impression material was used to simulate the periodontal ligament. After periodontal ligament simulation, the specimens were subjected to a compressive load at a crosshead speed of 0.5 mm/min in a servo-hydraulic testing machine (MTS 810) applied at 135 to the long axis of the tooth until failure. The data (N) were subjected to ANOVA and Tukey's post-hoc test (alpha=0.05). Results: GI and GIV presented higher fracture strength (p<0.05) than GII. GIII presented intermediate values without statistically significant differences (p>0.05) from GI, GII and GIV. Control specimens (GV) produced the lowest fracture strength mean values (p<0.05). Despite obtaining the highest mean value, GI presented 100% of unfavorable failures. GII presented 20% of unfavorable failures. GIII, GIV and GV presented only favorable failures. Conclusions: Although further in vitro and in vivo studies are necessary, the results of this study showed that the use of direct and indirect anatomic posts in flared roots could be an alternative to cast metal post-and-core.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A common approach used to estimate landscape resistance involves comparing correlations of ecological and genetic distances calculated among individuals of a species. However, the location of sampled individuals may contain some degree of spatial uncertainty due to the natural variation of animals moving through their home range or measurement error in plant or animal locations. In this study, we evaluate the ways that spatial uncertainty, landscape characteristics, and genetic stochasticity interact to influence the strength and variability of conclusions about landscape-genetics relationships. We used a neutral landscape model to generate 45 landscapes composed of habitat and non-habitat, varying in percent habitat, aggregation, and structural connectivity (patch cohesion). We created true and alternate locations for 500 individuals, calculated ecological distances (least-cost paths), and simulated genetic distances among individuals. We compared correlations between ecological distances for true and alternate locations. We then simulated genotypes at 15 neutral loci and investigated whether the same influences could be detected in simple Mantel tests and while controlling for the effects of isolation-by distance using the partial Mantel test. Spatial uncertainty interacted with the percentage of habitat in the landscape, but led to only small reductions in correlations. Furthermore, the strongest correlations occurred with low percent habitat, high aggregation, and low to intermediate levels of cohesion. Overall genetic stochasticity was relatively low and was influenced by landscape characteristics.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the effects of motor intervention on the neuropsychiatric symptoms of Alzheimer's disease and on the caregivers' burden. DESIGN: This is a controlled trial evaluating the effects of a motor intervention program on the neuropsychiatric symptoms. SETTING: The intervention was performed on community patients from two university centers specializing in physical exercise for the elderly. SUBJECTS: Patients with Alzheimer's disease were divided into two groups: sixteen received the motor intervention and sixteen controls (five controls were excluded because of clinical intercurrences). INTERVENTIONS: Aerobic exercises (flexibility, strength, and agility) and functional balance exercises were conducted over six months for 60 minutes three times per week. MAIN MEASURES: Psychopathological features of patients were evaluated with the Neuropsychiatric Inventory and Cornell Scale for Depression in Dementia. Caregivers were evaluated using the Neuropsychiatric Inventory-Distress and Burden Interview. A two-way analysis of variance (ANOVA) was applied to observe interactions (pre- vs. post-intervention; participants vs. controls). RESULTS: Patients from the intervention presented a significant reduction in neuropsychiatric conditions when compared to controls (Neuropsychiatric Inventory: F: 11.12; p = 0.01; Cornell Depression scale: F: 11.97; p = 0.01). The burden and stress of caregivers responsible for patients who participated in the intervention significantly decreased when compared to caregivers responsible for controls (Neuropsychiatric Inventory-Distress: F: 9.37; p = 0.01; Burden Interview: F: 11.28; p = 0.01). CONCLUSIONS: Aerobic exercise was associated with a reduction in the neuropsychiatric symptoms and contributed to attenuate the caregivers' burden. However, the researchers were not blinded to the patient's intervention status, which constitutes an important limitation of this study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Oliveira, AS, Greco, CC, Pereira, MP, Figueira, TR, de Araujo Ruas, VD, Goncalves, M, and Denadai, BS. Physiological and neuromuscular profile during a Bodypump session: acute responses during a high-resistance training session. J Strength Cond Res 23(2): 579-586, 2009-The main purposes of this study were 1) to describe and to compare blood lactate ([La]), heart rate (HR), and electromyographic (EMG) parameters during high-repetition training sessions (HRTSs), 2) to analyze the influence of physical fitness levels in these parameters, and, 3) to analyze the relationship between metabolic ([La]) and neuromuscular (EMG) responses during the HRTS. Fifteen healthy untrained women (21.7 +/- 2.1 years) performed an HRTS called Bodypump for 1 hour, which incorporated the use of variable free weights and high repetitions in a group setting. This session involved 10 music selections (M1-M10) containing resistive exercises for different muscle groups. After music selections 2 (M2), 4 (M4), 6 (M6), 7 (M7), and 9 (M9), [La], HR, and EMG (vastus medialis [VM], vastus lateralis [VL], iliocostalis lumborum [IC], and longissimus thoracis <) were determined. The [La] (M2, 4.00 +/- 1.45 mM; M7, 5.02 +/- 1.73 mM) and HR (M2, 153.64 +/- 18.89 bpm; M7, 16.14 +/- 20.14 bpm) obtained at M2 and M7 were similar but were significantly higher than the other moments of the session. However, EMG (root mean square [RMS]) at M2 (VL, VM, and LT) was lower than at M7. There was no significant correlation of strength and aerobic physical fitness with [La], RMS. In the same way, there was no significant correlation of [La] with RMS at M2 and M7. on the basis of our data, we can conclude that metabolic, cardiovascular, and EMG variables present different and independent behavior during an HRTS. Accordingly, for neuromuscular conditions during HRTS, it seems to be enough to induce improvement in the muscular strength of inferior limbs in untrained subjects.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Gurjao, ALD, Goncalves, R, de Moura, RF, and Gobbi, S. Acute effect of static stretching on rate of force development and maximal voluntary contraction in older women. J Strength Cond Res 23(7): 2149-2154, 2009-The purpose of this study was to investigate, in older women, the acute effect of static stretching (SS) on both muscle activation and force output. Twenty-three older women (64.6 +/- 7.1 yr) participated in the study. The maximal voluntary contraction (MVC), rate of force development (RFD) (50, 100, 150, and 200 ms relative to onset of muscular contraction), and peak RFD (PRFD) (the steepest slope of the curve during the first 200 ms) were tested under 2 randomly separate conditions: SS and control (C). Electromyographic (EMG) activity of the vastus medialis (VM), vastus lateralis (VL), and biceps femoris (BF) muscles also was assessed. The MVC was significantly lower (p < 0.05) in the 3 trials of SS when compared with the C condition (control: 925.0 +/- 50.9 N; trial 1 : 854.3 +/- 55.3 N; trial 2 : 863.1 +/- 52.2 N; and trial 3 : 877.5 +/- 49.9 N). PRFD showed a significant decrease only for the first 2 trials of SS when compared with the C condition (control: 2672.3 +/- 259.1 N/s; trial 1 : 2296.6 +/- 300.7 N/s; and trial 2 : 2197.9 +/- 246.3 N/s). However, no difference was found for RFD (50, 100, 150, and 200 ms relative to onset of muscular contraction). The EMG activity for VM, VL, and BF was not significantly different between the C and SS conditions. In conclusion, the older women's capacity to produce muscular force decreased after their performance of SS exercises. The mechanisms responsible for this effect do not appear to be related to muscle activation. Thus, if flexibility is to be trained, it is recommended that SS does not occur just before the performance of activities that require high levels of muscular force.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)