155 resultados para resistance of plants
Resumo:
Salt stress decreases the osmotic potential of soil solution causing water stress, causing toxic effects in the plants resulting in injuries on the metabolism and nutritional disorders, thus compromising the plant growth, resulting in lower production. The calcium silicate and magnesium can perform the same function as limestone, besides providing silicon to plants, may also contribute to the resistance of plants to salt stress. Thus, the objective of this study was to evaluate the effect of calcium and magnesium silicate on the growth of the castor oil plant BRS Energia cultivated under saline conditions. This study evaluated plant height, stem diameter, number of leaves, leaf area, dry weight of shoot and root, and soil chemical characteristics. There was no interaction between factors of salinity level and of silicate level regarding the evaluated variables. There was a direct relationship between salinity levels and plant growth in height and stem diameter. The K concentration in soil were affected by salinity levels.
Resumo:
A trial was carried out to determine the resistance to natural infection by gastrointestinal nematodes in 12 Santa Inês and nine Ile de France lambs before weaning. Faecal samples were obtained for faecal nematode egg counts (FEC). Blood samples were collected to determine packed cell volume (PCV), total plasma protein levels and peripheral eosinophil counts. Most Ile de France lambs (77.8%) were treated with an anthelmintic at 43 days of age, while 50% off Santa Inês lambs were treated at weaning, 57 days of age. The mean PCV values were normal in Santa Inês lambs, while in Ile de France lambs showed lower values reaching 22.3% at 43 days of age. The lowest mean plasma protein values were observed in Ile de France lambs (4.13 g/dl) at 43 days of age and in Santa Inês lambs (5.0 g/dl) at 57 days of age. Before weaning, Santa Inês lambs were susceptible to natural infections by gastrointestinal nematodes but with a greater capacity to stand the adverse effects of parasitism compared to Ile de France lambs.
Resumo:
Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-μm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-μm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O 3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-μm SiO x particles + silane). After 24 h of water storage at 37°C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37°C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. Results: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. Conclusion: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.
Resumo:
Ti-6Al-4V samples have been treated by PHI processing at different temperatures (400-800°C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti 2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time.
Resumo:
Purpose: The aim of this study was to evaluate the fracture resistance of ceramic plates cemented to dentin as a function of the resin cement film thickness. Materials and Methods: Ceramic plates (1 and 2 mm thicknesses) were cemented to bovine dentin using resin composite cement. The film thicknesses used were approximately 100, 200, and 300 μm. Noncemented ceramic plates were used as control. Fracture loads (N) were obtained by compressing a steel indenter in the center of the ceramic plates. ANOVA and Tukey tests (α = 0.05) were used for each ceramic thickness to compare fracture loads among resin cement films used. Results: Mean fracture load (N) for 1-mm ceramic plates were: control - 26 (7); 100 μm - 743 (150); 200 μm - 865 (105); 300 μm - 982 (226). Test groups were significantly different from the control group; there was a statistical difference in fracture load between groups with 100 and 300 μm film thicknesses (p < 0.01). Mean fracture load for 2-mm ceramic plates were: control - 214 (111); 100 μm - 1096 (341); 200 μm - 1067 (226); 300 μm - 1351 (269). Tested groups were also significantly different from the control group (p < 0.01). No statistical difference was shown among different film thicknesses. Conclusions: Unluted specimens presented significantly lower fracture resistance than luted specimens. Higher cement film thickness resulted in increased fracture resistance for the 1-mm ceramic plates. Film thickness did not influence the fracture resistance of 2-mm porcelain plates. Copyright © 2007 by The American College of Prosthodontists.
Resumo:
This investigation compares the peritrophic membrane (PM) morphology along the midgut of susceptible (SL) and resistant (RL) Anticarsia gemmatalis larvae to the AgMNPV. The PM increased the thickness from the anterior to the posterior midgut region in both insects strain; however, the intensity of FITC-WGA reaction of the PM in the RL were greater than in SL. The PM in RL was ultrastructurally constituted by several layers of fibrous/vesicular materials in comparison with the few ones in SL. Our results showed that the structure of PM in the RL could be one of the resistance barriers to AgMNPV. © 2007.
Resumo:
This study evaluated the effect of post surface conditioning on the fatigue resistance of bovine teeth restored with resin-bonded fiber-reinforced composite (FRC). Root canals of 20 single-rooted bovine teeth (16 mm long) were prepared to 12 mm using a preparation drill of a double-tapered fiber post system. Using acrylic resin, each specimen was embedded (up to 3.0 mm from the cervical part of the specimen) in a PVC cylinder and allocated into one of two groups (n = 10) based on the post surface conditioning method: acid etching plus silanization or tribochemical silica coating (30 μm SiOx + silanization). The root canal dentin was etched (H2PO3 for 30 seconds), rinsed, and dried. A multi-step adhesive system was applied to the root dentin and the fiber posts were cemented with resin cement. The specimens were submitted to one million fatigue cycles. After fatigue testing, a score was given based on the number of fatigue cycles until fracture. All of the specimens were resistant to fatigue. No fracture of the root or the post and no loss of retention of the post were observed. The methodology and the results of this study indicate that tribochemical silica coating and acid etching performed equally well when dynamic mechanical loading was used.
Resumo:
The aim of this study is to evaluate the flexural resistance of three types of restorative materials: compomer (Freedom), resin-modified glass-ionomer (Vitremer) and composite resin (Esthet-X), observing whether the application of bleaching agent can cause alterations of their flexural properties. Sixty samples were made using a 10 x 1 x 1 mm brass mold, and divided into three groups: G1- Freedom (SDI); G2- Vitremer (3M ESPE); G3- Esthet-X (Dentsply). On half of the samples of each group (10 samples) the bleaching treatment was applied and the other half used as control, was stored in distilled water at a temperature of 37 degrees C. Whiteness HP Maxx bleaching system was applied on the sample surface following the manufacturer's recommendations, simulating the bleaching treatment at the clinic. After this period, a flexural strength (three-point bending) test was conducted using (EMIC DL 1000) machine until the samples fractured. The data were submitted to ANOVA and Tukey tests. Of the restorative materials studied, G3-(87.24 +/- 31.40 MPa) presented the highest flexural strength, followed by G1-(61.67 +/- 21.32 MPa) and G2-(61.67 +/- 21.32 MPa). There was a statistical difference in flexural strength after the bleaching treatment. It was concluded that the use of a beaching agent can promote significant alteration of the flexural strength of these restorative materials.
Resumo:
Aim To assess the dimensional characteristics, flexibility and torsional behaviour of nickel-titanium retreatment instruments. Methodology Using image analysis software and high-resolution digital images, the instrument length, tip angle, diameter at 3mm from the tip and the distance between the blades (pitch length) of the following eight instruments were measured (n=12 for each measurement parameter): the ProTaper Universal retreatment (PTU-R) D1, D2 and D3 instruments; the R-Endo R1, R2 and R3 retreatment instruments; and the Mtwo retreatment (Mtwo-R) sizes 25 and 15 retreatment instruments. Maximum torque and the angular deflection at fracture as well as the bending moment at 45° were measured (n=12) according to the International Standards Organisation (ISO) specification number 3630-1. Data were analysed using the analysis of variance (α=0.05). Results The length of the active part of the instruments was found to vary according to the depth of the canal into which they were designed to reach. The pitch length also increased along the active length. The PTU-R D1 and the Mtwo-R instruments had active tips. Measurements of the bending moment at 45° revealed that the Mtwo-R 15 instrument was the most flexible, whereas the PTU-R D1 was the least flexible. The maximum torque tended to increase as the instrument diameter at 3mm from the tip increased, whereas the angular deflection at fracture varied in the opposite direction. Conclusions The geometrical characteristics of the retreatment instruments and their flexibility and torsion behaviour were consistent with their intended clinical application. © 2011 International Endodontic Journal.
Resumo:
A total of 24 extracts from 14 plant species collected at the state of Minas Gerais, Brazil, and belonging to five botanical families (Annonaceae, Apocynaceae, Ochnaceae, Polygonaceae and Vitaceae) was screened for cytotoxicity in cultured Vero cells and for antiviral activity against human herpes virus type 1 (HSV-1), vaccinia virus (VACV) and murine encephalomyocarditis virus (EMCV). The highest cytotoxicity (CC 50 < 10 μg/mL) was observed for the ethanol extracts from Annona coriacea fruits and seeds. Extracts from Hancornia speciosa, Ouratea castaneafolia and O. semisrrata were the only ones that have shown activity against all the three viruses assayed. Extracts from Polygonum spectabile, Hancornia speciosa, Himatanthus phagedaenica, Ouratea spectabilis and O. semiserrata were the most active against HSV-1 (EC 50 < 50 mg/mL), with favorable SI values (8.0 to 10.0). Hancornia speciosa and Anaxagorea dolichocarpa were the most active against EMCV (EC 50 50 - 100 μg/mL), with reasonable SI values (5.2 to 6.1), while moderate to low activity (EC 50 > 100 μg/mL) was observed for Ouratea spectabilis and O. semiserrata. A total of 7 plant species, Ouratea semiserrata, O. spectabilis, O. castanaeafolia, Rollinia laurifolia, Cissus erosa, Polygonum spectabile, and Hancornia speciosa, were active against VACV, disclosing EC50 < 50 μg/mL and SI values ranging from 6.6 to 67.3. In total, 10 out of the 14 species were selected from a literature survey on plants used to treat viral diseases in Brazil; these species were responsible for 70% of the positive results.
Resumo:
The fracture resistance of endodontically treated teeth has been an obstacle to the durability of the remaining teeth and restorations. The aim of this study was to evaluate the fracture resistance of endodontically treated bovine and human teeth that were restored with either prefabricated metal posts, glass fiber posts, or composite resin cores. Statistical analysis revealed significant difference between different substrates, but there was no statistically significant difference between different types of intraradicular posts or in the interaction between substrate and post types. The intraradicular posts do not increase the fracture resistance of endodontically treated teeth. The metal posts presented more unfavorable fracture modes when compared to glass fiber posts and composite resin cores.
Resumo:
Aim: Compare the effect of three post designs on the fracture resistance and failure modes of composite core-fiber post-crownless tooth sets. Materials and Methods: Ninety bovine incisors were selected and divided into nine groups of 10 specimens. The teeth were assigned to three groups based on the post design: Cylindrical, tapered, and double-tapered. Each group was subdivided into three subgroups in accordance with the diameter of the post: Small (No.1), medium (No.2), and large (No.3). The Panavia F system was used for post cementation. The specimens were mounted in acrylic resin blocks with a layer of silicone rubber covering the roots. A universal testing machine compressively loaded the specimens from the palatal side at a crosshead speed of 1 mm/min and at an angle of 135I to the long axis of the teeth, until failure occurred. The failure mode was determined by a stereomicroscope inspection of all the specimens. Data were analyzed by one-way ANOVA and the Tukey test (P < 0.05). Results: The fracture resistance was affected by the type of post (P < 0.0001). A narrower diameter for all of the post systems allowed for higher resistance. The main failure mode in the large cylindrical group was catastrophic fractures, while the main failures in the other eight groups were favorable. Conclusion: Narrower diameter posts showed higher fracture resistance. The dominant failure pattern was repairable fracture, except for those with large cylindrical groups.
Resumo:
The objective of this study was evaluate the effect of the log steaming on the chemical properties and decay resistance of Eucalyptus grandis wood. Logs with diameter between 20 and 22 cm were studied. Half of logs were kept in its on original condition, and the other half was steamed at 90°C for 13 hours. The holocellulosc, Klason lignin, total extractives content and the weight loss caused by the decay fungus Pycnoporus sanguineous were characterized. The results showed that the log steaming of E. grandis wood cause: (l)a significantly decreased in holocellulose content; (2) an increase of 4.8% and 4.4% in total extractives and lignin content, respectively; and (3) a decrease in its durability against the decay fungus P. sanguineus in order of 13.03%. Copyright © (2012) by WCTE 2012 Committee.
Resumo:
The Brazilian Savanna (locally called Cerrado) is an important biome presenting several plants that are used in popular medicine. However, the risks associated with the consumption of derivatives from these plants are generally unknown. Studies with compounds obtained from different species have shown the risks of DNA damage. The present work assessed the in vivo mutagenicity of three plant species used in popular medicine to treat human gastrointestinal disorders (Mouriri pusa, Qualea grandiflora and Qualea multiflora). The micronucleus assay was performed in peripheral blood of mice submitted to acute treatments. Results showed that no assessed extracts were mutagenic in vivo. In fact, the absence of mutagenicity in the present study indicates that the extracts do not contain compounds capable of inducing DNA breaks or chromosomal loss. However, further analysis should be performed in others systems to guarantee their safety, mainly to human chronic use.