106 resultados para real power loss


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study the growth dynamics of the size of manufacturing firms considering competition and normal distribution of competency. We start with the fact that all components of the system struggle with each other for growth as happened in real competitive business world. The detailed quantitative agreement of the theory with empirical results of firms growth based on a large economic database spanning over 20 years is good with a single set of the parameters for all the curves. Further, the empirical data of the variation of the standard deviation of the growth rate with the size of the firm are in accordance with the present theory rather than a simple power law. (C) 2003 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The neutral wire in most power flow software is usually merged into phase wires using Kron's reduction. Since the neutral wire and the ground are not explicitly represented, neutral wire and ground currents and voltages remain unknown. In some applications, like power quality and safety analyses, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of special interest. In this paper, a general power flow algorithm for three-phase four-wire radial distribution networks, considering neutral grounding, based on backward-forward technique, is proposed. In this novel use of the technique, both the neutral wire and ground are explicitly represented. A problem of three-phase distribution system with earth return, as a special case of a four-wire network, is also elucidated. Results obtained from several case studies using medium- and low-voltage test feeders with unbalanced load, are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Smoking is a well-known risk factor for destructive periodontal disease, but its relationship with periodontal status and subgingival microbiota remains unclear. Inherent limitations of microbiological methods previously used may partly explain these mixed results, and real-time polymerase chain reaction (PCR) has been presented as a valid alternative. The aim of the present study was to investigate the clinical condition and microbiological profile of patients with chronic periodontitis as related to the habit of smoking.Methods: Fifty patients (33 to 59 years old), 25 smokers and 25 never-smokers, constituted the sample. The visible plaque index (VPI), gingival bleeding index (GBI), bleeding on probing (BOP), periodontal probing depth (PD), clinical attachment loss (CAL), and gingival crevicular fluid (GCF) volume were recorded. Real-time PCR quantified Porphyromonas gingivalis, Micromonas micros, Dialister pneumosintes, Actinobacillus actinomycetemcomitans and total bacteria in subgingival samples.Results: Smokers and never-smokers showed similar values for VPI, GBI, and BOP. Smokers had deeper PD in buccal/lingual sites and higher CAL independently of the tooth surface. The GCF volume was smaller in smokers, independent of the PD. Similar amounts of total bacteria and P. gingivalis were observed for both groups. Significantly higher numbers of D. pneumosintes and M. micros were present in smokers and associated with moderate and deep pockets. When heavy smokers were considered, higher counts of total bacteria, M. micros, and D. pneumosintes were observed.Conclusions: Smoking seems to have a detrimental impact on the periodontal status and microbiological profile of patients with periodontitis. Compared to never-smokers, smokers had deeper pockets, greater periodontal destruction, and higher counts of some putative periodontal pathogens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this research was to verify the effect of age on the exponent of the power function in Perceptive, Memory, and Inference experimental conditions. In the Memory condition the intervals of 2 min., 8, 24, and 48 hr. and 1 wk. were used between acquisition of information and remembering. For each experimental condition the ages of observers ranged between 17 and 35 years (Group I), 40-55 years (Group II), and 60-77 years (Group III), and education ranged from high school to graduate school. The observers estimated the areas of the Brazilian states using the psychophysical method of magnitude estimation. No significant differences were obtained for Groups I, II, and III for each experimental condition, except in the Memory Condition with the 24-hr. interval. Analysis for experimental conditions and ages showed a significant difference between the Perceptive Condition and each of the others, but no difference between the Inference and Memory Conditions. These results indicated that in the remembering processes there is no loss of information as a function of age. From the small variability in the power function exponents for the three ages, we may assume that age could be related to amount of education of the observers, which suggests study is important.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an analysis and discussion, based on cooperative game theory, for the allocation of the cost of losses to generators and demands in transmission systems. We construct a cooperative game theory model in which the players are represented by equivalent bilateral exchanges and we search for a unique loss allocation solution, the Core. Other solution concepts, such as the Shapley Value, the Bilateral Shapley Value and the Kernel are also explored. Our main objective is to illustrate why is not possible to find an optimal solution for allocating the cost of losses to the users of a network. Results and relevant conclusions are presented for a 4-bus system and a 14-bus system. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This letter presents an approach for a geometrical solution of an optimal power flow (OPF) problem for a two-bus system (slack and PV busses). The algebraic equations for the calculation of the Lagrange multipliers and for the minimum losses value are obtained. These equations are used to validate the results obtained using an OPF program.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The lake from Porto-Primavera hydroelectric power station inundated an area of 2,200 km2 at the border of São Paulo and Mato-Grosso do Sul States, Brazil. Infestations by ticks were evaluated on 135 marsh deer, Blastocerus dichotomus (Illiger), captured before and after inundation. Ticks were collected for identification, and infestation level of animals was assessed by scoring. Deer were divided into four groups according to capture location and temporal relation to the inundation. Groups 1, 2, and 3 were captured before inundation. Group 4 was captured after inundation. Four tick species were found: Amblyomma cajennense (F.), Amblyomma triste Koch, Anocentor nitens (Neumann), and Boophilus microplus (Canestrini). Groups 1, 2, 3, and 4 had 30, 45, 100, and 96%, respectively, of animals carrying B. microplus ticks. A. triste was observed on 16, 22, 22, and 88% of animals from groups 1,2,3, and 4, respectively. A. nitens and A. cajennense were observed only on group 4, on 32 and 16% of the animals, respectively. Groups 1 and 2 had only 4.8 and 6.1% of animals with high infestation levels, respectively, and no ticks on 46.8% and 45.5% of the animals, respectively. Conversely, groups 3 and 4 lacked noninfested animals and had high infestation levels on 77.8 and 50% of deer, respectively. Marsh area shrinkage was blamed for higher infestation levels on deer from groups 3 and 4. The widespread presence of A. triste on marsh deer, a Neotropical tick species, raises the possibility of a natural host-parasite relationship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Distribution systems with distributed generation require new analysis methods since networks are not longer passive. Two of the main problems in this new scenario are the network reconfiguration and the loss allocation. This work presents a distribution systems graphic simulator, developed with reconfiguration functions and a special focus on loss allocation, both considering the presence of distributed generation. This simulator uses a fast and robust power flow algorithm based on the current summation backward-forward technique. Reconfiguration problem is solved through a heuristic methodology and the losses allocation function, based on the Zbus method, is presented as an attached result for each obtained configuration. Results are presented and discussed, remarking the easiness of analysis through the graphic simulator as an excellent tool for planning and operation engineers, and very useful for training. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For a typical non-symmetrical system with two parallel three phase transmission lines, modal transformation is applied using some examples of single real transformation matrices. These examples are applied searching an adequate single real transformation matrix to two parallel three phase transmission line systems. The analyses are started with the eigenvector and eigenvalue studies, using Clarke's transformation or linear combinations of Clarke's elements. The Z C and parameters are analyzed for the case that presents the smallest errors between the exact eigenvalues and the single real transformation matrix application results. The single real transformation determined for this case is based on Clarke's matrix and its main characteristic is the use of a unique homopolar reference. So, the homopolar mode becomes a connector mode between the two three-phase circuits of the analyzed system. ©2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In transmission line transient analyses, a single real transformation matrix can obtain exact modes when the analyzed line is transposed. For non-transposed lines, the results are not exact. In this paper, non-symmetrical and non transposed three-phase line samples are analyzed with a single real transformation matrix application (Clarke's matrix). Some interesting characteristics of this matrix application are: single, real, frequency independent, line parameter independent, identical for voltage and current determination. With Clarke's matrix use, mathematical simplifications are obtained and the developed model can be applied directly in programs based on time domain. This model works without convolution procedures to deal with phase-mode transformation. In EMTP programs, Clarke's matrix can be represented by ideal transformers and the frequency dependent line parameters can be represented by modified-circuits. With these representations, the electrical values at any line point can be accessed for phase domain or mode domain using the Clarke matrix or its inverse matrix. For symmetrical and non-transposed lines, the model originates quite small errors. In addition, the application of the proposed model to the non-symmetrical and non-transposed three phase transmission lines is investigated. ©2005 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low flexibility and reliability in the operation of radial distribution networks make those systems be constructed with extra equipment as sectionalising switches in order to reconfigure the network, so the operation quality of the network can be improved. Thus, sectionalising switches are used for fault isolation and for configuration management (reconfiguration). Moreover, distribution systems are being impacted by the increasing insertion of distributed generators. Hence, distributed generation became one of the relevant parameters in the evaluation of systems reconfiguration. Distributed generation may affect distribution networks operation in various ways, causing noticeable impacts depending on its location. Thus, the loss allocation problem becomes more important considering the possibility of open access to the distribution networks. In this work, a graphic simulator for distribution networks with reconfiguration and loss allocation functions, is presented. Reconfiguration problem is solved through a heuristic methodology, using a robust power flow algorithm based on the current summation backward-forward technique, considering distributed generation. Four different loss allocation methods (Zbus, Direct Loss Coefficient, Substitution and Marginal Loss Coefficient) are implemented and compared. Results for a 32-bus medium voltage distribution network, are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the considerable increase of the losses in electric utilities of developing countries, such as Brazil, there is an investigation for loss calculation methodologies, considering both technical (inherent of the system) and non-technical (usually associated to the electricity theft) losses. In general, all distribution networks know the load factor, obtained by measuring parameters directly from the network. However, the loss factor, important for the energy loss cost calculation, can only be obtained in a laborious way. Consequently, several formulas have been developed for obtaining the loss factor. Generally, it is used the expression that relates both factors, through the use of a coefficient k. Last reviews introduce a range of factor k within 0.04 - 0.30. In this work, an analysis with real life load curves is presented, determining new values for the coefficient k in a Brazilian electric utility. © 2006 IEEE.