156 resultados para physical parameters


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Geografia - IGCE

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radiotherapy is a field of medical physics, which has been going through a scientific and technological advancement, it is extreme important the professionals that work in this area continuous their study to improve the quality of service provided. For it, they should know the physical principles related as well their employment in radiotherapy. The electrons have been using in therapy of superficial tumors, because they show rapid decrease of dose in depth, they don’t expose the deeper tissues to radiation. The electron therapy has replaced the surface therapy with x-ray and mold brachytherapy, and nowadays, it represents 10 to 15% of radiotherapy treatments. This study brings the definition of physical parameters used in the dosimetry of electron beam, describes the tests for quality control of linear accelerator with a electrons beam, as well the activities realized in the Radiotherapy Division, of Hospital de Clinicas, in the Universidade Estadual of Campinas, in the Clinac 2100C machine

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The treatment of a tumor with ionizing radiation is an ongoing process with well differentiated stages. These ones include the tumor diagnosis and location, the decision on the treatment strategy, the absorbed dose planning and calculation, the treatment administration, the absorbed dose verification and the evaluation of results in short and long terms. The quality of a radiotherapy procedure is closely linked to factors that may be classified as clinical, such as the diagnosis, the tumor location, the treatment strategy chosen and the continuous treatment reassessment; dosimetric or physical, such as the uncertainty in the dose calculation, its optimization and verification, the suitability of the equipment to provide a radiation beam consistent with the treatment planning; finally, others which are related to the practical application of radiotherapy treatment and the handling of the patient. In order to analyze the radiotherapy quality, one should realize that the three aspects (medical, physical or dosimetric and practical application) should be considered in a combined way. This means that numerous actions of the radiotherapists, medical physicists and technicians in radiotherapy should be held jointly and their knowledge level will significantly affect the treatment quality. In this study, the main physical parameters used in dosimetry are defined as well as determined experimentally for a linear accelerator Mevatron - MXT. With this, it is intended to provide recommendations for the physical aspects of Quality Assurance (QA) in the radiotherapy treatments, and these will usually be applied by professionals in Medical Physics. In addition to these instructions, it is recommended that additional texts are prepared to address in detail the clinical aspects of the treatments QA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This project has several objectives: To determine medium values and variations of the density, porosity, humidity, shrinkage volume and the coefficient of mass attenuation of gamma radiation of 59,6 keV of the radioisotope 241Am, using samples of equine radio, in growth and adult. The samples of bones were supplied by the Department of Pathology of University of Veterinary Medicine and Zootechnics - UNESP campus Botucatu. Bones of the paws front left of two males were used. Of each bone ten samples were removed. Those samples were prepared to just obtain compact bony fabric, being submitted to the rehearsal of determination of the density by the immersion method in water and determination of the coefficient attenuation lineal for the method of attenuation of the radiation of the 241Am, also obtaining your humidity content. Still, they were obtained new samples starting from the ground samples and verified the density of the particles present in that, obtaining the medium value of the coefficient of mass attenuation. The results showed the medium values and significant statistical variations of the density, porosity, humidity, shrinkage volume and coefficient of mass attenuation of gamma radiation of 59, 6 keV of the radioisotope 241Am in the samples, establishing some relationships between of the certain physical parameters with biological aspects and possible existent influences between them

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public