99 resultados para least squares method


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The main target here is to determine the orbit of an artificial satellite, using signals of the GPS constellation and least squares algorithms implemented through sequential Givens rotations as a method of estimation, with the aim of improving the performance of the orbit estimation process and, at the same time, minimizing the computational procedure cost. Geopotential perturbations up to high order and direct solar radiation pressure were taken into account. It was also considered the position of the GPS antenna on the satellite body that, lately, consists of the influence of the satellite attitude motion in the orbit determination process. An application has been done, using real data from the Topex/Poseidon satellite, whose ephemeris is available at Internet. The best accuracy obtained in position was smaller than 5 meters for short period (2 hours) and smaller than 28 meters for long period (24 hours) orbit determination. In both cases, the perturbations mentioned before were taken into consideration and the analysis occurred without selective availability on the signals measurements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A caprinocultura leiteira no Brasil, apesar de ser uma atividade rural consolidada há algumas décadas, tem se mostrado totalmente dependente de outros países no que se refere ao melhoramento genético. A maioria dos plantéis existentes atualmente tem como base animais importados, e a renovação do material genético é feita por meio da importação de sêmen. Inexistem informações sobre o valor genético dos animais e sua evolução no decorrer dos anos. No presente trabalho, foram estimadas a herdabilidade e a repetibilidade da produção de leite utilizando o REML. Os valores obtidos foram 0,21557 e 0,21564, respectivamente. Para a predição do valor gênico dos animais, foi usado o procedimento BLUP com modelo animal. A mudança na tendência genética anual estimada por um modelo quadrático foi -0,8109 kg/ano², indicando desaceleração no ganho genético. A correlação de Pearson entre os valores gênicos dos bodes estimados com base na média da capacidade provável de produção das filhas obtida pelo método de mínimos quadrados com as estimadas pelas equações do modelo misto foi de 0,5751. A correlação de SPEARMAN entre as classificações dos bodes obtidos pelos dois métodos foi de 0,5813.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objetivou-se, no presente estudo, avaliar a produção de leite de caprinos leiteiros da região sudeste do Brasil, com intuito de verificar os fatores de meio e estimar os parâmetros genéticos pelo método dos mínimos quadrados (MMQ). Os controles de 1336 lactações foram inicialmente ajustados pela função multifásica (difásica) e calculou-se a produção de leite total (PLT). Os dados foram provenientes de sete propriedades e três raças (Parda Alpina, Saanen e Toggenburg). A média e o erro-padrão da PLT estimados pelo MMQ foram de 635,31 ±39,75 kg. A interação ano x estação do parto influenciou a PLT. em um dos anos estudados, a PLT foi menor para as cabras paridas no final da estação. Nas três estações de parto, observou-se comportamento quadrático da PLT, em função dos anos de parto. Para as três estações, a PLT aumentou de 1986 até meados de 1990, decrescendo em seguida. A idade de máxima PLT foi observada aos 46,65 meses. Das três raças estudadas, observou-se que as raças Parda Alpina e Saanen apresentaram alternância de superioridade na PLT em algumas fazendas, porém maiores que a Toggenburg. Os coeficientes de herdabilidade e repetibilidade da PLT estimados pelo MMQ foram de 0,296 ± 0,079 e 0,277 ± 0,033, respectivamente. Estes resultados revelam baixa confiabilidade em poucas observações dessas características ou na inconsistência das estimativas da função multifásica. Como a PLT é uma característica limitada ao sexo, sugere-se o teste de progênie como método de seleção mais eficiente para os reprodutores e uso de inseminação artificial como processo de disseminação do material genético selecionado.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The element-free Galerkin method (EFGM) is a very attractive technique for solutions of partial differential equations, since it makes use of nodal point configurations which do not require a mesh. Therefore, it differs from FEM-like approaches by avoiding the need of meshing, a very demanding task for complicated geometry problems. However, the imposition of boundary conditions is not straightforward, since the EFGM is based on moving-least-squares (MLS) approximations which are not necessarily interpolants. This feature requires, for instance, the introduction of modified functionals with additional unknown parameters such as Lagrange multipliers, a serious drawback which leads to poor conditionings of the matrix equations. In this paper, an interpolatory formulation for MLS approximants is presented: it allows the direct introduction of boundary conditions, reducing the processing time and improving the condition numbers. The formulation is applied to the study of two-dimensional magnetohydrodynamic flow problems, and the computed results confirm the accuracy and correctness of the proposed formulation. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Data on age at first kidding (IPP) were collected on seven farms in the Brazilian Southeastern region which explored breds. Least squares (LS) were used to evaluate the effects of environmental factors and to estimate variance components, and the derivative-free restricted maximum likelihood (DFREML) method was used to estimate the variance components of IPP and to genetically evaluate the goats used in the southest region of Brazil. The LS mean and standard error of IPP were 607.18 +/- 17.09 days. The interaction of year x kidding season had a significantly influenced IPP, indicating that management conditions varied among the seasons within each specific year, with a direct influence on body weight which is the main criterion adopted by farmers to decide when the animal is ready to breed. The effect of farm-breed combination influenced the IPP. The compararison among levels of farm-breed were done by cluster analysis. The results indicated that the individual goat management within each farm had a greater influence than breed, since goats of different breeds showed high and similar values on those farms having a high mean IPP. Heritability estimates obtained by LS using intraclass correlations among paternal half-sibs and those obtained by REML were 0.220 and 0.369, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fourteen complexes in the series [RuCl2(CO)(L)(PPh3)2] (where L = N-heterocycles) have been prepared and characterized by IR and NMR spectroscopies, and cyclic voltammetry. A good correlation is found between observed and calculated electrochemical potentials; E1/2 vs pKa or (Gp, σm for a series of similar ligands. It is now reported that the carbonyl stretching frequency, νCO, and the 13C and 31P NMR signals do not correlate well with any of the physico-chemical parameters used (E1/2, Taft's and Hammett's parameters). This behaviour is probably due to the characteristics of the Ru(II) species, which does not transmit the steric and electron donor/acceptor properties of the ligands to the carbonyl group, or because the measurements are not able to detect the effect induced by the changes in the ligand L. Indeed, good correlations are obtained when the measurements directly involve the metal centre, as is the case in the E1/2 measurements. Crystals of o[RuCl2(CO)(4-pic)(PPh3)2] are monoclinic, space group P21/n, a = 12.019(2), b = 13.825(3) and c = 22.253(3) . The structure was solved by the Patterson method and was refined by full-matrix least-squares procedure to R = 0.054 and Rw = 0.055, for 2114 reflections with I > 3σ(I). For L = 2-acetylpyridine and 2-methylimidazole, complexes with formulae [RuCl2(CO)(L)(PPh3)] · L and [RuCl2(CO)(L)2 (PPh3)], respectively, were obtained. © 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Systematic errors can have a significant effect on GPS observable. In medium and long baselines the major systematic error source are the ionosphere and troposphere refraction and the GPS satellites orbit errors. But, in short baselines, the multipath is more relevant. These errors degrade the accuracy of the positioning accomplished by GPS. So, this is a critical problem for high precision GPS positioning applications. Recently, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique. It uses a natural cubic spline to model the errors as a function which varies smoothly in time. The systematic errors functions, ambiguities and station coordinates, are estimated simultaneously. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The GPS observables are subject to several errors. Among them, the systematic ones have great impact, because they degrade the accuracy of the accomplished positioning. These errors are those related, mainly, to GPS satellites orbits, multipath and atmospheric effects. Lately, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique (PLS). In this method, the errors are modeled as functions varying smoothly in time. It is like to change the stochastic model, in which the errors functions are incorporated, the results obtained are similar to those in which the functional model is changed. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method (CLS). In general, the solution requires a shorter data interval, minimizing costs. The method performance was analyzed in two experiments, using data from single frequency receivers. The first one was accomplished with a short baseline, where the main error was the multipath. In the second experiment, a baseline of 102 km was used. In this case, the predominant errors were due to the ionosphere and troposphere refraction. In the first experiment, using 5 minutes of data collection, the largest coordinates discrepancies in relation to the ground truth reached 1.6 cm and 3.3 cm in h coordinate for PLS and the CLS, respectively, in the second one, also using 5 minutes of data, the discrepancies were 27 cm in h for the PLS and 175 cm in h for the CLS. In these tests, it was also possible to verify a considerable improvement in the ambiguities resolution using the PLS in relation to the CLS, with a reduced data collection time interval. © Springer-Verlag Berlin Heidelberg 2007.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents an approach for structural health monitoring (SHM) by using adaptive filters. The experimental signals from different structural conditions provided by piezoelectric actuators/sensors bonded in the test structure are modeled by a discrete-time recursive least square (RLS) filter. The biggest advantage to use a RLS filter is the clear possibility to perform an online SHM procedure since that the identification is also valid for non-stationary linear systems. An online damage-sensitive index feature is computed based on autoregressive (AR) portion of coefficients normalized by the square root of the sum of the square of them. The proposed method is then utilized in a laboratory test involving an aeronautical panel coupled with piezoelectric sensors/actuators (PZTs) in different positions. A hypothesis test employing the t-test is used to obtain the damage decision. The proposed algorithm was able to identify and localize the damages simulated in the structure. The results have shown the applicability and drawbacks the method and the paper concludes with suggestions to improve it. ©2010 Society for Experimental Mechanics Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper is reported the use of the chromatographic profiles of volatiles to determine disease markers in plants - in this case, leaves of Eucalyptus globulus contaminated by the necrotroph fungus Teratosphaeria nubilosa. The volatile fraction was isolated by headspace solid phase microextraction (HS-SPME) and analyzed by comprehensive two-dimensional gas chromatography-fast quadrupole mass spectrometry (GC. ×. GC-qMS). For the correlation between the metabolic profile described by the chromatograms and the presence of the infection, unfolded-partial least squares discriminant analysis (U-PLS-DA) with orthogonal signal correction (OSC) were employed. The proposed method was checked to be independent of factors such as the age of the harvested plants. The manipulation of the mathematical model obtained also resulted in graphic representations similar to real chromatograms, which allowed the tentative identification of more than 40 compounds potentially useful as disease biomarkers for this plant/pathogen pair. The proposed methodology can be considered as highly reliable, since the diagnosis is based on the whole chromatographic profile rather than in the detection of a single analyte. © 2013 Elsevier B.V..

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction Jatropha gossypifolia has been used quite extensively by traditional medicine for the treatment of several diseases in South America and Africa. This medicinal plant has therapeutic potential as a phytomedicine and therefore the establishment of innovative analytical methods to characterise their active components is crucial to the future development of a quality product. Objective To enhance the chromatographic resolution of HPLC-UV-diode-array detector (DAD) experiments applying chemometric tools. Methods Crude leave extracts from J. gossypifolia were analysed by HPLC-DAD. A chromatographic band deconvolution method was designed and applied using interval multivariate curve resolution by alternating least squares (MCR-ALS). Results The MCR-ALS method allowed the deconvolution from up to 117% more bands, compared with the original HPLC-DAD experiments, even in regions where the UV spectra showed high similarity. The method assisted in the dereplication of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. Conclusion The MCR-ALS method is shown to be a powerful tool to solve problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd. Extracts from J. gossypifolia were analyzed by HPLC-DAD and, dereplicated applying MCR-ALS. The method assisted in the detection of three C-glycosylflavones isomers: vitexin/isovitexin, orientin/homorientin and schaftoside/isoschaftoside. The application of MCR-ALS allowed solving problems of chromatographic band overlapping from complex mixtures such as natural crude samples. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ciências Cartográficas - FCT

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)