77 resultados para internal jugular vein


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Knowledge of the effectiveness of prostaglandins in uterine involution process led to the development of protocols with its analogues in postpartum period. However, this hormone mechanism of action is not yet fully elucidated. Thus, the objective of this study was to verify if chloprostenol administration, at early or intermediary puerperium, can induce changes on progesterone, PGFM and oestradiol plasma concentrations. 30 Murrah postpartum buffaloes were randomly divided into three groups: CONT (saline, n = 10); CLO2 (chloprostenol at days 2 and 5 postpartum, n = 10) and; CLO15 (chloprostenol at days 15 and 20 postpartum, n = 10). Blood samples were collected from jugular vein to measure progesterone, PGFM and oestradiol plasma concentrations at days 2, 7, 14, 21 and 28 postpartum. CLO2 group presented lower progesterone and PGFM plasma concentrations in relation to CONT and CLO15 groups (0.23 +/- 0.00 and 0.32 +/- 0.11, 0.19 +/- 0.00 and 0.23 +/- 0.11, 0.23 +/- 0.00 and 0.30 +/- 0.19, for groups CONT, CLO2 and CLO15, respectively; P < 0.05). There was no significant difference in oestradiol plasma concentration between experimental groups (P > 0.05). Prostaglandin synthetic analogue administration induced hormonal changes in postpartum buffaloes, which can partially explain its positive effect under reproductive function of this specie.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Cell-dyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510) and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson's correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semi-automated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the effect of raloxifene (RLX) during progression of periapical lesions in ovariectomized (OVX) rats. Methods: Female Wistar rats were OVX or subjected to sham surgery and received vehicle or MX by gavage for 90 days. The treatment groups were as follows: sham surgery and treated with vehicle (SHAM-veh), OVX and treated with vehicle (OVX-veh), and OVX and treated with RLX (OVX-RLX). During treatment, the pulp of lower first molar was exposed to the oral. environment for induction of periapical lesion that was analyzed 7 or 30 days aftdr procedure. Blood samples were taken from jugular vein for measurement of estradiol, and the mandibles were removed and prepared for radiographic, histopathologic, histometric, and immunohistochemical analysis. Results: Estradiol plasma concentration showed hypoestrogenism in OVX rats. The histopathologic analysis of the OVX/RLX group was similar to that of the SHAM-veh group, whereas OVX-veh group showed larger penapical lesions with more intense inflammatory response and more cells positive for tartrate-resistant acid phosphatase. Radiographically, the groups were similar, but lesions on day 7 were smaller than lesions on day 30. Conclusions: The results suggest that hypoestrogenism potentiates the progression of periapical lesions, and such condition was reversed by treatment with RLX.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The urgent need for studies using standardized protocols to evaluate the real biological effects of PRP has been emphasized by several authors. Objective: The purpose of this study was to standardize a methodology for autologous Platelet-Rich Plasma (PRP) preparation in rats. Material and methods: Twentyfour, 5 to 6-month-old, male rats, weighing 450 to 500 g were used. After general anesthesia, 3.15 ml of blood was collected from each animal, via cannulation of the jugular vein. A standardized technique of double centrifugation was used to prepare PRP. PRP samples and peripheral blood platelets were then manually counted using a Neubauer chamber. Student’s t-test was used to compare the differences between the number of platelets in peripheral blood and PRP samples (p < 0.05). In addition, PRP and peripheral blood smears were stained to see platelets’ morphology. Results: All surgical procedures were well tolerated by the animals and they were healthy during the entire experimental period. PRP samples showed higher significantly platelet concentrations than peripheral blood samples (2,677,583 and 683,680 respectively). Conclusion: Within the limits of this study, it can be concluded that the method used produced autologous PRP with appropriated platelet quantity and quality, in rats.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A case of iatrogenic fistula from the right internal mammary artery to the subclavian vein following subclavian vein catheterization is reported. The patient had undergone percutaneous Intracath catheterization of the subclavian vein to treat hypovolemic shock during the surgical treatment of ectopic pregnancy. She had remained symptom-free for 7 years and then started to complain of effort dyspnea. The patient was found to have a thrill and a bruit at the subclavian region, and arteriography demonstrated a fistula between the right internal mammary artery and the subclavian vein. The fistula was successfully closed by embolization with a percutaneous detachable balloon catheter. © 1993.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although veins and arteries present similar wall structures, there are differences which may be relevant in peripheral nerve reconstruction. Inside-out vein grafts (IOVG) have been satisfactorily used to repair both motor and sensitive nerves. However, the inside-out artery graft (IOAG) is a new technique and not fully investigated. Our study presents comparative morphological data on nerve regeneration achieved with IOVG and IOAG in the repair of Wistar rat sciatic nerves. Jugular veins and aorta arteries were harvested from donor animals and used inside-out to bridge a 10-mm gap. Animals were sacrificed at 10 weeks to evaluate nerve regeneration. Both techniques presented great variability in nervous tissue, though some animals showed satisfactory results. Different intensities of scarring processes might have interfered with nerve regeneration. Although IOVG and IOAG techniques showed similar morphometric results, in general, IOVG presented a closer-to-normal nerve organization than IOAG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.