134 resultados para horizontal movement
Resumo:
There occurs a biological response of the tissues of dental support, in answer to the external physiological forces and those realized during clinical treatments with orthodontical purposes. These forces differ from the first ones because they are continuous and time dependent. A great dental mobility is related to the degree of tissue organization of the periodontium system and the orthodontical movement must utilize this exceptional capacity of renewal and adaptation of the periodontium structures adequately. Therefore, through histological means a search was made to evaluate the succession of alterations of the periodontium system after the application of an orthodontical force on the molars of young rats and to interpret the standards of horizontal mobility and their consequences on the periodontium structures, biologically. An orthodontic force was applied on young rats utilizing steel wire placed in a ring form on a contact point between the first and second lower molars. The animals were sacrificed after 30 minutes, 1, 2, 6, 12, 24, 48, 72, 96 and 168 hours after the placement of the metal ring. After technical preparation, the microscopic slides were examined and the results were compared. In all the sections there was evidence of an intense metabolic activity. A gradual evolution of modification on the phenomenons had occurred.
Resumo:
The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.
Resumo:
The mucosa that covers the residual ridges of edentulous patients may present some distortion or displacement when occlusal loading is applied in complete dentures. This distortion and movement of the denture can result in acceleration of residual ridge resorption and loss of retention and stability. The aim of this study was to analyze the pattern of upper complete denture movement related to underlying mucosa displacement. A sample of 10 complete denture wearers was randomly selected, which had acceptable upper and lower dentures and normal volume and resilience of residual ridges. The kinesiographic instrument K6-I Diagnostic System was used to measure denture movements, according to the method proposed by Maeda et al.7, 1984. Denture movements were measured under the following experimental conditions: (A) 3 maximum voluntary clenching cycles and (B) unilateral chewing for 20 seconds. The results showed that under physiological load, oral mucosa distortion has two distinct phases: a fast initial displacement as load is applied and a slower and incomplete recovery when load is removed. Intermittent loading such as chewing progressively reduces the magnitude of the denture displacement and the recovery of the mucosa is gradually more incomplete.
Resumo:
The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.
Resumo:
This study describes preliminary laryngeal electromyography (LEMG) data and botulinum toxin treatment in patients with dysphonia due to movement disorders. Twenty-five patients who had been clinically selected for botulinum toxin administration were examined, 19 with suspected laryngeal dystonia or spasmodic dysphonia (SD), 5 with vocal tremor, and 1 with Gilles de la Tourette syndrome (GTS). LEMG evaluations were performed before botulinum toxin administration using monopolar electrodes. Electromyography was consistent with dystonia in 14 patients and normal in 5, and differences in frequency suggesting essential tremor in 3 and Parkinson tremors in 2. The different LEMG patterns and significant improvement in our patients from botulinum toxin therapy has led us to perform laryngeal electromyography as a routine in UNICAMP movement disorders ambulatory.
Resumo:
In this study it is reported the operation of a horizontalflow anaerobic immobilized biomass (HAlB) reactor under sulfate-reducing condition which was also exposed to different amounts of ethanol and benzene. The HAIB reactor comprised of an immobilized biomass on polyurethane foam and ferrous and sodium sulfate solutions were used (91 and 550 mg.l -1, respectively), to promote a sulfate-reducing environment. Benzene was added at an initial concentration of 2.0 mg.l -1 followed by an increased to 9 e 10 mg. l -1, respectively. Ethanol was added at an initial concentration of 170 mg.l -1 followed by an increased range of 960 mg.l -1. The reactor was operated at 30 (± 2) °C with hydraulic detention time of 12 h. Organic matter removal efficiency of 90% with a maximum benzene degradation rate of 0.07 mv, benzene.mg -1 vss.d -1 Thus, this work corroborate the data obtained for Cattony et al (2005) and also demonstrate that compact units of HAIB reactors, under sulfate reducing conditions, are a potential alternative for in situ aromatic compounds bioremediation.
Resumo:
An agent based model for spatial electric load forecasting using a local movement approach for the spatiotemporal allocation of the new loads in the service zone is presented. The density of electrical load for each of the major consumer classes in each sub-zone is used as the current state of the agents. The spatial growth is simulated with a walking agent who starts his path in one of the activity centers of the city and goes to the limits of the city following a radial path depending on the different load levels. A series of update rules are established to simulate the S growth behavior and the complementarity between classes. The results are presented in future load density maps. The tests in a real system from a mid-size city show a high rate of success when compared with other techniques. The most important features of this methodology are the need for few data and the simplicity of the algorithm, allowing for future scalability. © 2009 IEEE.
Resumo:
The objective of this work was to assess the knowledge about orthodontic tooth movement and dental trauma held by a group of orthodontists in specific areas of Brazil. For this purpose, 166 questionnaires with 15 objective questions about this subject were distributed. One hundred and five questionnaires were properly filled and collected after 30 days. It was concluded that, except for avulsion, the knowledge on dental injuries held by the professionals interviewed was considered unsatisfactory, and about 40% of them were not acquainted with the recommendations for the orthodontic movement of traumatized teeth.
Resumo:
Aim: To evaluate the influence of construction bite in the dentoskeletal changes induced by Klammt Appliance. Methods: The sample consisted of 17 children, with Class II malocclusion and initial mean age of 8.5 years. The construction bite was obtained using an Exactobite on edge-toedge anteroposterior relationship with 3 mm interincisal clearance. The height of the acrylic was determined by initial overbite associated to interincisal clearance and measured with digital caliper. The amount of advancement was obtained and measured by initial overjet in the lateral radiography. Pearson's correlation, linear regression and ANOVA were used to determine the relationship between dentoskeletal and construction bite variables. Results: The increase in the height of the acrylic promotes a greater inhibition of the forward displacement of the nasal spine and reduction in the facial growth index. The increase in the mandibular advancement induces more downward displacement of nasal spine and pogonion; a counter-clockwise rotation of palatine plane; an increase in mandibular length, maxillary alveolar height and interincisal angle; a decrease in mandibular alveolar height, the intermaxillary discrepancy and overjet; and palatal tipping of upper incisors. Conclusions: The different dimensions of the construction bite influence the dentoskeletal changes induced by the appliance in Class II treatment.
Resumo:
One of the main purposes of mucogingival therapy is to obtain full root coverage. Several treatment modalities have been developed, but few techniques can provide complete root coverage in a class III Miller recession. Thus, the aim of this case report is to present a successful clinical case of a Miller class III gingival recession in which complete root coverage was obtained by means of a multidisciplinary approach. A 17-year-old Caucasian female was referred for treatment of a gingival recession on the mandibular left central incisor. The following procedures were planned for root coverage in this case: free gingival graft, orthodontic movement by means of alignment and leveling and coronally advanced flap (CAF). The case has been followed up for 12 years and the patient presents no recession, no abnormal probing depth and no bleeding on probing, with a wide attached gingiva band. A compromised tooth with poor prognosis, which would be indicated for extraction, can be treated by orthodontic movement and periodontal therapy, with possibility of 100% root coverage in some class III recessions.
Resumo:
The stride before landing may be important during stepping down. The aim of this study was to analyze variability of the kinematics and muscle activity in the final stride before stepping down a curb, with and without ankle and knee muscle fatigue. Ten young participants walked at self-selected speed and stepped down a height difference (10-cm) in ongoing gait. Five trials were performed before and after a muscle fatigue protocol (one day: ankle muscle fatigue, another day: knee muscle fatigue). The analysis focused on the trailing leg during the last but one and the last step on the higher level. Kinematics and muscle activity were recorded. Fatigue increased variability of foot-step horizontal distance in the last step on the higher level of the trailing limb, as well as in the first steps on the lower level for both limbs. This appeared due to an increase in the range of motion of the knee joint after both fatigue protocols. Participants additionally showed an increased ankle and hip ROM and decreased knee ROM. Our results suggest a loss of control under fatigue reflected in a higher variability of trailing and leading limb-step horizontal distances, with compensatory changes to limit fatigue effects, such as a redistribution of movement over joints. © 2012 Elsevier B.V.
Resumo:
Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.
Resumo:
How individual-level movement decisions in response to habitat edges influence population-level patterns of persistence and spread of a species is a major challenge in spatial ecology and conservation biology. Here, we integrate novel insights into edge behavior, based on habitat preference and movement rates, into spatially explicit growth-dispersal models. We demonstrate how crucial ecological quantities (e.g., minimal patch size, spread rate) depend critically on these individual-level decisions. In particular, we find that including edge behavior properly in these models gives qualitatively different and intuitively more reasonable results than those of some previous studies that did not consider this level of detail. Our results highlight the importance of new empirical work on individual movement response to habitat edges. © 2013 by The University of Chicago.
Resumo:
Background/Aim: The present research evaluated the induction of ankylosis and the eruption rate in rat incisors, with the aim of achieving stable anchorage for orthodontic tooth movement (OTM) of the molars. Material and methods: Fifteen male Wistar rats were used. In the Experimental group, the right superior incisor of each animal was extracted, denuded of the PDL and the dental papilla, and reimplanted. The Control group was the left superior incisors. The eruption rate was measured at 7, 10, 12, 14, and 16 days after replantation. NiTi closed springs with a 50cN release force were installed for additional 9 days, and the eruption rate was determined. Then, the rats were sacrificed, and ankylosis was examined by microscopic analysis. Differences with P < 0.01 were defined as statistically significant. Results: The eruption rates were 0 and 0.39 mm day-1 in the Experimental group and Control group, respectively. All incisors of the Experimental group showed ankylosis according to histological analysis. Conclusions: The methodology used to induce ankylosis in this study was effective for anchoring the incisors during the OTM of rat molars, eliminating the undesirable effects consequent to continuous eruption. © 2013 John Wiley & Sons A/S.
Resumo:
Aim To compare the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) in an absorbable collagen sponge carrier (ACS) with autogenous bone graft for augmentation of the edentulous atrophic anterior maxilla. Methods Twenty-four subjects were enrolled in a randomized, controlled, parallel-group, open-label clinical trial. Subjects either received rhBMP-2/ACS (1.5 mg/ml) or particulated autogenous bone harvested from the mandibular retromolar region. A titanium-mesh was used to provide space and wound stability. A guide was used to standardize clinical recordings using an analogue caliper. Alveolar ridge width was also assessed using cone-beam computed tomography. Results rhBMP-2/ACS yielded significantly greater radiographic horizontal bone gain compared with autogenous bone graft at immediate subcrestal levels (1.5 ± 0.7 versus 0.5 ± 0.9 mm; p = 0.01); non-significant differences were observed at mid- (2.9 ± 0.8 versus 2.9 ± 0.9 mm; p = 0.98) and apical (1.7 ± 0.9 versus 1.8 ± 1.1 mm; p = 0.85) crestal levels. No significant differences in clinical horizontal bone gain were observed at 6 months between rhBMP-2/ACS and autogenous bone graft (3.2 ± 0.9 mm versus 3.7 ± 1.4 mm; p = 0.31). Sixty-two implants were placed after 6 month of healing with no significant differences between groups for number of implants, implant size, primary stability and survival. Conclusions rhBMP-2/ACS appears a realistic alternative for augmentation of the edentulous atrophic anterior maxilla. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.