75 resultados para electromyographic activity
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.
Resumo:
The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.
Resumo:
The purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.
Resumo:
Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.
Resumo:
The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.
Resumo:
We often face Patients searching for rehabilitation for lower back disorders during the physiotherapeutic routine, and it is known that the abdominal muscle, specially the rectus abdominis muscle, aid the stabilization of the pelvis. Therefore, this paper analyzes the electrical activity of the rectus abdominis muscle in the pelvic retroversion in dorsal decubitus and in orthostatic position and in the lowering of the lower limbs. 30 healthy students, male and female, 17-40 yr, divided into two groups - Group 1: 15 volunteers (pelvic balance); Group 2 (pelvic unbalance) took part in this study. The electrical activity of the right and left supra-umbilical and infra-umbilical portions of the rectus abdominis muscle was detected. The mean RMS values from three attempts ftom the electromyographic traces were usedfor the analysis of the electrical activity. The RMS value was submitted to the normalization process. The data were submitted to statistic treatment by the Friedman test, and the analyses of the means and standard deviation towards a level of significance of 95%. The results demonstrated that the portions of the rectus abdominis muscle presented low electrical activity for the groups studiedfor pelvic retroversion either in dorsal decubitus or and orthostatic position. However, the decreasing movement of the lower limbs towards the portions of the rectus abdominis muscle presented more significant electrical activity whereas the lower portions presented higher activity than the higher ones for Group 2.
Resumo:
Electromyography is frequently used to measure the activity of masticatory muscles. It requires the precise setting of the electrodes, which demands the accurate location of the muscle to be evaluated. The purpose of this study was to investigate the accuracy of an external method to locate the buccinator muscle. Fifteen human cadavers were evaluated and planes were etermined on the face using anatomic landmarks. An angle (α) was obtained at the intersection of these planes on the central point of buccinator muscle and measured with a protractor. The value of the angle allows locating the central point of buccinator muscle based on anatomic landmarks on the face. Statistical analysis of the collected data indicated an angle of 90° with 95% reliability, thus proving the efficacy of the proposed method.
Resumo:
Presently, acupuncture is a technique considered to be capable of stimulating the regulatory systems of the organism, such as the central nervous system, the endocrine system and the immunological system. The median frequency of the upper trapezium muscle with 40% and 60% of maximal voluntary contraction (MVC) of 15 healthy volunteers, was analyzed after the individuals were submitted to the AA treatment. The non-parametric Friedman test was used to compare median frequency values. In this exploratory study, the level of significance of each comparison was set to p < 0.05. The intraclass analyses indicate a significant increase of the median frequency muscle at 60% of the MVC (Wicoxon test). Based on the results found, the AA peripheral stimulus can act as a modulator mechanism of muscle activity and was possible to verify correspondence of the auricular acupoint with the trapezius muscle. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
Bruxism is widely defined as an anxiety response to environmental stress. Occlusal splints are frequently used in sleep bruxism, to protect teeth from damage resulting from the contraction force of mandibular muscles, or to reduce the orofacial pain by relaxing masticatory muscles. Surface electromyography (EMG) of the right and left masseter and temporalis muscles was performed in 15 women presenting sleep bruxism and temporomandibular disorders related to occupational stress, after nocturnal use of the occlusal splint. The EMG signals were recorded twice per patient: After a work shift (pre-splint) and after a night of sleep with the occlusal splint (post-splint) before a new workday. The parametric t-paired test was used to compare differences of the RMS amplitude between pre and post-splint records, for resting and maximal clenching effort. The level of significance for each comparison was set to p < 0.05. The results of the study supports the premise that the use of occlusal splint reduces EMG activity in the masseter and anterior temporalis muscles, in patients who presented with sleep bruxism related to occupational stress. © 2011 Elsevier Ltd.
Resumo:
This study aimed to analyze the electromyographic (EMG) activity of iliocostalis lumborum (IL), internal oblique (IO) and multifidus (MU) and the antagonist cocontraction (IO/MU and IO/IL) during the performance of Centering Principle of Pilates Method. Participating in this study were eighteen young and physically fit volunteers, without experience in Pilates Method, divided in two groups: low back pain group (LBPG, n = 8) and control group (CG, n = 10). Two isometric contractions of IO muscles (Centering Principle) were performed in upright sitting posture. EMG signal amplitude was calculated by Root Mean Square (RMS), which was normalized by RMS maximum value. The common area method to calculate the antagonist cocontraction index was used. MU and IO activation and IO/MU cocontraction (. p < 0.05) were higher in CG. The CG therefore showed a higher stabilizer muscles recruitment than LBPG during the performance of Centering Principle of Pilates Method. © 2012 Elsevier Ltd.
Resumo:
The trapezius muscle (superior, middle and inferior portions) was analyzed in 20 volunteers. The electromyographic tests were carried out using a four-channel TECA TE 2-7 electromyograph with surface- and single coaxial needle electrodes. In abduction, adduction and flexion-extension, the 3 portions show increasing and decreasing activity, respectively, from the beginning until the end of these movements. In hyperextension, the 3 portions show increasing activity from the beginning until the end of the movement, with greater participation of the middle portion. Significant differences were not observed in the electromyographic profile of the trapezius, using surface and needle electrodes.
Resumo:
The objective of this study is to analyze the simultaneity of the actions of the three portions of the trapezius (superior portion = TS; middle portion = TM and inferior portion = TI) in elevation, lowering, retraction and protraction of the shoulders. The electromyographic tests were carried out in 20 volunteers using a 4-channel TECA TE 2-7 electromyograph and surface and single coaxial needle electrodes. The electromyographs, obtained with the two types of electrodes, show that in elevation and lowering of the shoulders, TS and TM present increasing and decreasing activity, respectively, from the beginning until the end of these movements. In retraction of the shoulders, TM and TI present increasing activity from the beginning to the end of the movement. In protraction, TS, TM and TI do not show any activity.
Resumo:
The objective of this paper was to analyse the activity of the longissimus dorsi and the iliocostalis lumborum muscles--components of the erector spinae muscle--in order to determine: their action potentials during the use of a plain and a tilt Roman table; 2) to compare the action potentials of the two muscles; 3) to verify if the action potential of these two muscles remain constant during the arc of movement--knee flexion and extension--divided into angle ranges, and 4) to compare the action potentials of the muscles in movements performed in a free manner and against resistance. Twenty-three young volunteers were studied electromyographically and each muscle received a needle electrode (Mise) and a surface electrode. The results showed that the table model did not determine any difference in the action potential of the muscles and that, on average, the iliocostalis lumborum muscle developed a slightly higher action potential than the longissimus dorsi muscle during the free flexion of knees on the plain table. In more than 70% of the cases, there was no difference between the action potential of the muscles over the various angle ranges of knee flexion and extension. Relatively higher action potentials were recorded during knee flexion and extension against resistance than during the same movements performed in a free manner. This shows that the paravertebral musculature responds better to an overload (8 kg) imposed on the knee flexor group, confirming the stabilizing role of the longissimus dorsi and iliocostalis lumborum muscles during knee flexion and extension on a Roman table.
Quantitative end qualitative analysis of the electrical activity of rectus abdominis muscle portions
Resumo:
The purpose of this study was to investigate the electrical behavior pattern of the Rectus abdominis muscle by qualitative and quantitative analysis of the electromyographic signal obtained from its superior, medium and inferior portions during dynamic and static activities. Ten voluntaries (aged X = 17.8 years, SD = 1.6) athletic males were studied without history of muscle skeletal disfunction. For the quantitative analysis the RMS (Root Mean Square) values obtained in the electromyographic signal during the isometric exercises were normalized and expressed in maximum voluntary isometric contraction percentages. For the qualitative analysis of the dynamic activity the electromyographic signal was processed by full-wave rectification, linear envelope and normalization (amplitude and time), so that the resulting curve of the processed signal was submitted to descriptive graphic analysis. The results of the quantitative study show that there is not a statistically significant difference among the portions of the muscle. Qualitative analysis demonstrated two aspects: the presence of a common activation electric pattern in the portions of Rectus abdominis muscle and the absence of significant difference in the inclination angles in the electrical activity curve during the isotonic exercises.