136 resultados para Water Distribution Networks Infrastructure Health


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em História - FCLAS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study aimed to evaluate the radial profile and the uniformity of water distribution of sprinkler manufactured by the company NaanDanJain, model 427 1/2 '' M and nozzle with 2.8 mm of internal diameter, operating at pressures of 150, 200, 300 and 400 kPa and five positions of the deflector (0, 20, 50, 80 and 100%). For the determination of the parameters evaluated, the grid method was used and with the help of computer application CATCH 3D, overlapping layers of water depths was calculated with ten spacing. The results show that the deflector adjustment influences the radius of wetness and the distribution profile while the uniformity of water application showed as an important mechanism, since it permits different behavior for the sprinkler, ensuring wide track of utilization of the equipment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Em solos tropicais, a distribuição dos nutrientes no solo em função da fertirrigação realizada por meio de irrigação localizada (gotejamento e/ou microaspersão), na cultura de citros, é pouco conhecida. Este trabalho teve por objetivo avaliar os padrões de distribuição de potássio, cálcio, magnésio e fósforo em solo tropical, em função da fertirrigação, aplicada por dois sistemas de irrigação localizada (microaspersão e gotejamento), sendo que o sistema por gotejamento era composto por uma e duas linhas laterais por linha de plantas, e o de microaspersão por apenas uma linha, e com três dotações hídricas (100%, 75% e 50%) da evapotranspiração da cultura (ETc), em um pomar de laranjeira. As fontes de fertilizantes utilizadas na fertirrigação foram o nitrato de amônio (fonte de N), o cloreto de potássio (fonte de K+) e o ácido fosfórico (fonte de P). Observouse que, sob o emissor, nos tratamentos com gotejamento, houve depleção nos teores de Ca++ e Mg++ desde a superfície do solo até 60 cm de profundidade em relação aos teores anteriores às fertirrigações, enquanto os teores de P aumentaram, principalmente na camada de 0 cm a 20 cm. Na microaspersão, esses efeitos não foram observados, ocorrendo distribuição mais homogênea desses nutrientes tanto na direção transversal à linha de plantas quanto em profundidade. As lâminas de irrigação aplicadas por irrigação localizada não interferem na distribuição de K+ aplicado por fertirrigação e do Ca++ e Mg++ no solo em profundidade, porém menores lâminas de irrigação promovem maior concentração de P na camada mais superficial do solo, e lâminas maiores carregam o P para camadas mais profundas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is based on the development and experimental analysis of a DCM Boost interleaved converter suitable for application in traction systems of electrical vehicles pulled by electrical motors (Trolleybus), which are powered by urban DC or AC distribution networks. This front-end structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The architecture of proposed converter is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode. Furthermore, the converter can operate as AC-DC converter, or as DC-DC converter providing the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards. The digital controller has been implemented using a low cost FPGA and developed totally using a hardware description language VHDL and fixed point arithmetic. Thus, two control strategies are evaluated considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, the regular PWM modulation and a current correction PWM modulation. In order to verify the feasibility and performance of the proposed system, experimental results from a 15 kW low power scale prototype are presented, operating in DC and AC conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy policies and technological progress in the development of wind turbines have made wind power the fastest growing renewable power source worldwide. The inherent variability of this resource requires special attention when analyzing the impacts of high penetration on the distribution network. A time-series steady-state analysis is proposed that assesses technical issues such as energy export, losses, and short-circuit levels. A multiobjective programming approach based on the nondominated sorting genetic algorithm (NSGA) is applied in order to find configurations that maximize the integration of distributed wind power generation (DWPG) while satisfying voltage and thermal limits. The approach has been applied to a medium voltage distribution network considering hourly demand and wind profiles for part of the U.K. The Pareto optimal solutions obtained highlight the drawbacks of using a single demand and generation scenario, and indicate the importance of appropriate substation voltage settings for maximizing the connection of MPG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this work was to characterize chemical and mineralogical the water supply networks and to assess the hydraulic recovery on high-degraded pipe. Thus, the resistance (by pitometric essays), chemical analyses (ICP-MS and ICP-ES), mineralogical analysis (petrographic thin sections, X-ray difractometry and scanning electronic microscopy), hardness (Mohs scale) and simulations for pipe's change and rehabilitations scenarios were investigated (from Scenario 1 to 4). The results showed that the high-degraded pipe had a limited recovery (from 3,9 to 14,0 m(0,367).s(-1)). The deposits were formed by oxide and hydroxide of iron (magnetite and goethite), which are materials of high hardness (6 on Mohs scale). The simulations indicated the required power ratio (C-i/C-1) around 86.00, 1.00 and 0.02% in relation to present scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analisar a qualidade da irrigação, além de avaliar seu bom funcionamento, é uma forma de verificar a viabilidade de sua implantação e operação. Como a uniformidade de distribuição é um dos parâmetros mais utilizados para essa avaliação, este trabalho objetivou utilizar técnicas de engenharia de qualidade, usando o índice de capacidade do processo (Cpl) para avaliar a uniformidade de distribuição de água em um sistema de irrigação por aspersão convencional. Os ensaios foram conduzidos no Núcleo Experimental de Engenharia Agrícola, UNIOESTE, com dois aspersores modelo Super10, marca NAANDAN, espaçados 9 m entre si, durante 25 irrigações de 1 h cada. Os dados climáticos foram coletados a cada 10 min, por uma estação meteorológica sem fio. Encontraram-se um CUC médio de 79,72% e velocidade do vento média de 1,85 m s-1. Foram aplicados os testes de controle de qualidade, elaborando os gráficos de controle de Shewhart e calculado o índice de capacidade do processo (Cpl), sendo que os resultados obtidos permitem afirmar que a utilização do índice de capacidade do processo torna-se uma ferramenta poderosa para classificar sistemas de irrigação em função de sua uniformidade de distribuição.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluating the technical impacts associated with connecting distributed generation to distribution networks is a complex activity requiring a wide range of network operational and security effects to be qualified and quantified. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and which could be used to shape the nature of the contract between the utility and distributed generator. This paper presents a multiobjective performance index for distribution networks with distributed generation which considers a wide range of technical issues. Distributed generation is extensively located and sized within the IEEE-34 test feeder, wherein the multiobjective performance index is computed for each configuration. The results are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last decade, distributed generation, with its various technologies, has increased its presence in the energy mix presenting distribution networks with challenges in terms of evaluating the technical impacts that require a wide range of network operational effects to be qualified and quantified. The inherent time-varying behavior of demand and distributed generation (particularly when renewable sources are used), need to be taken into account since considering critical scenarios of loading and generation may mask the impacts. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and for a given horizon. This paper presents a multiobjective performance index for distribution networks with time-varying distributed generation which consider a number of technical issues. The approach has been applied to a medium voltage distribution network considering hourly demand and wind speeds. Results show that this proposal has a better response to the natural behavior of loads and generation than solely considering a single operation scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)