254 resultados para Unilateral distalization


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the clinical and radiographic outcome in 8 dogs of surgical reduction of congenital humeroulnar luxation by using the transarticular pin. Five cases were bilateral and 3 were unilateral, for a total of 13 elbows. The treatment was performed in animals between 45 and 150 days of age. Articular stabilization was achieved by using a transarticular pin driven from the caudal aspect of the olecranon into the body of the humerus or into the distal condyle and distal metaphysis of the humerus. The follow-up period was between 1 and 19 months. There were 5 postsurgical reluxations, 3 related to the insertion of the pin into the humeral condyle and 3 related to the insertion into the humeral body. These animals needed further surgery. Six animals showed near normal return to limb function and 2 had lameness. We conclude that the use of the transarticular pin is an effective and simple method for the treatment of humeroulnar congenital elbow luxation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors report a rare case of bilateral Leydig cell tumor in a noncryptorchid stallion, describing the gross. and microscopic findings. An 8-year-old Appaloosa stallion was examined for a unilateral enlargement of the testis associated with discomfort during palpation and signs of colic. General health conditions were good. Fine-needle aspiration cytology of the testis provided the diagnosis of bilateral Leydig cell tumor. Bilateral orchiectomy was performed and the testes were submitted to histopathologic examination that confirmed the diagnosis of Leydig cell tumor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Solitary fibrous tumor (SFT) is a rare, benign, and very uncommon lesion in the orbit. Because of its complex and variable clinical and histological appearance the SIFT is often misdiagnosed.Cases: Two new cases of orbital SIFT are reported, one in a man and the other in a woman, both unilateral and in the superomedial orbit.Observations: Clinical and tomographical evaluations were conducted and the lesions were excised. The histological evaluation showed the tumors were composed of spindle-shaped cells within colla.-en bundles and vascular channels. Immunohistochemical staining was positive for CD 34 and negative for S-100 protein.Conclusion: Immunohistochemical study is an important adjuvant in determining the SIFT diagnosis. Long-term follow-up is necessary because of the possibility of SFT recurrence after excision. (C) 2003 Japanese Ophthalmological Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The caroticoclinoid foramen is an inconstant structure, formed by the union of the anterior and middle clinoid processes. The aim of this study was to perform an incidence and morphometry of the caroticoclinoid foramen in Brazilian human skulls and discuss its clinical implications. Eighty dry human skulls with sex distinction were used, and 3 groups of incidence were determined: General, sex, and sides. The morphometry was performed using a manual caliper and the major diameter of the foramina was measured; the values were also divided in general, according to sex and sides. The incidence of skulls with at least one foramen was 8.5%. According to the sides, 8.5% of the skulls showed foramen on the right side and 2.5% on the left. We found 2.5% of the skulls with bilateral foramen and 6.25% with unilateral foramen. In relation to sex, the foramens were found in 5% of male skulls and 12.5% of female skulls. The major diameter of this structure presented on mean, values of 5.23 mm on general, 5.18 mm on the right side and 5.35 mm on the left, 5.30 mm in male skulls and 5.18 mm in female skulls. The anatomical characteristics of this foramen should be considered in view of its clinical implications associated with neurosurgery as clinoid process removal, and symptoms as headache due to internal carotid artery alterations in this region. In conclusion knowledge of this structure supports the diagnosis and treatment of clinical complications related to this variation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The retromolar foramen allows the passage of the neurovascular bundles that contribute to nutrition and innervation of the pulp and periodontium of the lower teeth. Knowledge of this anatomical variation may prevent complications in the anesthesia and surgical procedures in this area and serve as an anatomical landmark for ethnic identification. The aim of this study was to evaluate the impact of the retromolar foramen in human mandibles of adult Brazilians and discuss the clinical and ethnic related to the presence of this foramen. Were evaluated 222 human mandibles, dry, adults, Brazilians, independent of gender. The evaluation was performed by two examiners who standardized search from a previous anatomical study. The mandibles were analyzed: the presence of the retromolar foramen (bilateral or unilateral), the presence of the foramen on right and left sides, and the number of foramens present on each side. It was found that 59 had at least one mandible retromolar foramens resulting in an incidence of 26.58%. The retromolar foramen was present unilaterally in 41 mandibles and 18 bilaterally, with incidences of 18.47% and 12.16% respectively. on the right side, the retromolar foramen was present in incidences of 16.22% and 18.92% respectively The analysis of the right side of the mandibles revealed that 47.46%, 21.21% and 3.03% had one, two and three foramens, respectively The left side showed 55.93%, 16.22% and 8.11% of the 222 mandibles with one, two and three retromolar foramens, respectively The incidence of retromolar foramen in the Brazilian population is significant and should be considered in the planning and execution of procedures in several areas of clinical practice dentistry in order to avoid complications. Moreover, it was found that the incidence of retromolar foramen contributes to differentiation of ethnic groups in the area of forensic anthropology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The misfit between prostheses and implants is a clinical reality, but the level that can be accepted without causing mechanical or biologic problem is not well defined. This study investigates the effect of different levels of unilateral angular misfit prostheses in the prosthesis/implant/retaining screw system and in the surrounding bone using finite element analysis. Four models of a two-dimensional finite element were constructed: group I (control), prosthesis that fit the implant; groups 2 to 4, prostheses with unilateral angular misfit of 50, 100, and 200 mu m, respectively. A load of 133 N was applied with a 30-degree angulation and off-axis at 2 mm from the long axis of the implant at the opposite direction of misfit on the models. Taking into account the increase of the angular misfit, the stress maps showed a gradual increase of prosthesis stress and uniform stress in the implant and trabecular bone. Concerning the displacement, an inclination of the system due to loading and misfit was observed. The decrease of the unilateral contact between prosthesis and implant leads to the displacement of the entire system, and distribution and magnitude alterations of the stress also occurred.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)