82 resultados para TIME-DOMAIN METHOD


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increased availability of soil water is important for the management of non-irrigated orange orchards. The objective of this study was to evaluate the availability of soil water in a Haplorthox (Rhodic Ferralsol) under different tillage systems used for orchard plantation, mulch management and rootstocks in a "Pera" orange orchard in northwest Parana, Brazil. An experiment in a split-split-plot design was established in 2002, in an area cultivated with Brachiaria brizantha grass in which three tillage systems (no tillage, conventional tillage and strip-tillage) were used for orchard plantation. This grass was mowed twice a year between the rows, representing two mulch managements in the split plots (no mulching and mulching in the plant rows). The split-split-plots were represented by two rootstocks ("Rangpur" lime and "Cleopatra" mandarin). The soil water content in the plant rows was evaluated in the 0-20 cm layer in 2007 and at 0-20 and 20-40 cm in 2008-2009. The effect of soil tillage systems prior to implantation of orange orchards on soil water availability was less pronounced than mulching and the rootstocks. The soil water availability was lower when "Pera" orange trees were grafted on "Cleopatra" mandarin than on "Rangpur" lime rootstocks. Mulching had a positive influence on soil water availability in the sandy surface layer (020 cm) and sandy clay loam subsurface (20-40 cm) of the soil in the spring. The production of B. brizantha between the rows and residue disposal in the plant rows as mulch increased water availability to the "Pera" orange trees.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The capacitor-commutated converter (CCC) has frequently been used in the conception of HVDC systems connected to busbars with low short circuit level. This alternative arrangement, in substitution to the conventional ones, guarantees less sensitive operational conditions to problems related with the commutation failure in the inverters besides supplying part of the reactive energy to be compensated. Studies related with its performance in steady and transient states have been presented in several works, however its behavior as harmonic source is still little explored. This work presents preliminary studies focusing the generation of characteristic harmonics by this type of converter. Subjects related with the amplification of the harmonic magnitudes are investigated and compared considering similar arrangements of conventional static converters (LCC) and CCC schemes. It is also analyzed the harmonic generation on the dc side of the installation and its influence on the ac side harmonics. The results are obtained from simulations in the time domain in PSpice environment and they clearly illustrate the operational differences between the L CC and the CCC schemes with regard to characteristic harmonic generation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a method for calculating the power flow in distribution networks considering uncertainties in the distribution system. Active and reactive power are used as uncertain variables and probabilistically modeled through probability distribution functions. Uncertainty about the connection of the users with the different feeders is also considered. A Monte Carlo simulation is used to generate the possible load scenarios of the users. The results of the power flow considering uncertainty are the mean values and standard deviations of the variables of interest (voltages in all nodes, active and reactive power flows, etc.), giving the user valuable information about how the network will behave under uncertainty rather than the traditional fixed values at one point in time. The method is tested using real data from a primary feeder system, and results are presented considering uncertainty in demand and also in the connection. To demonstrate the usefulness of the approach, the results are then used in a probabilistic risk analysis to identify potential problems of undervoltage in distribution systems. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article shows a transmission line model for simulation of fast and slow transients, applied to symmetrical or asymmetrical configurations. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents a practical procedure to model three-phase transmission lines directly in time domain, without the explicit or implicit use of inverse transforms. In three-phase representation, analysis modal techniques are applied to decouple the phases in their respective propagation modes, using a correction procedure to set a real and constant matrix for untransposed lines with or without vertical symmetry plane. The proposed methodology takes into account the frequency-dependent parameters of the line and in order to include this effect in the state matrices, a fitting procedure is applied. To verify the accuracy of the proposed state-space model in frequency domain, a simple methodology is described based on line distributed parameters and transfer function associated with input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust integration procedure to solve the state equations, enabling transient and steady-state simulations. The results obtained by the proposed methodology are compared with several established transmission line models in EMTP, taking into account an asymmetrical three-phase transmission line. The principal contribution of the proposed methodology is to handle a steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behavior, by a practical procedure applied directly in time domain for symmetrical or asymmetrical representations. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper is shown the development of a transmission line, based on discrete circuit elements that provide responses directly in the time domain and phase. This model is valid for ideally transposed rows represent the phases of each of the small line segments are separated in their modes of propagation and the voltage and current are calculated at the modal field. However, the conversion phase-mode-phase is inserted in the state equations which describe the currents and voltages along the line of which there is no need to know the user of the model representation of the theory in the field lines modal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper shows the insertion of corona effect in a transmission line model based on lumped elements. The development is performed considering a frequency-dependent line representation by cascade of pi sections and state equations. Hence, the detailed profile of currents and voltages along the line, described from a non-homogeneous system of differential equations, can be obtained directly in time domain applying numerical or analytic solution integration methods. The corona discharge model is also based on lumped elements and is implemented from the well-know Skilling-Umoto Model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: the associations between autonomic function and biventricular function in patients with the indeterminate form of Chagas disease remains to be elucidated.Methods: In 42 asymptornatic patients and 19 healthy volunteers, the autonomic function was assessed by time domain indices of heart rate variability (HRV), analyzed for 24 h; the right ventricular function was assessed by fraction area change, right ventricle shortening, and systolic excursion of the tricuspid valve; and the left ventricular function was assessed by ejection fraction and transmittal flow velocities. Data were expressed as mean SD or medians (including the lower quartile and upper quartile). Groups were compared by Student's t or Mann-Whitney U test. Autonomic and ventricular function were correlated by Pearson's or Spearman's correlation coefficient. The level of significance was 5%.Results: Right and left ventricular systolic function indexes were comparable between groups. Transmittal flow velocities were decreased in the Chagas disease group (p < 0.05). The patients presented impaired HRV as indicated by the values of SDNN-day (80 (64-99) ms vs. 98 (78-127) ms; p = 0.045), SDNNI-24 It (54 (43-71) vs. 65 (54-105) ms; p = 0.027), SDNNI-day (49 (42-64) vs. 67 (48-76) ms; p = 0.045), pNN50-day (2.2 (0.7-5)% vs. 10 (3-11)%; p = 0.033); and pNN50-24 It (3 (1-7)% vs. 12 (8-19)%; p = 0.013). There were no correlations between the left ventricular diastolic indices and autonomic dysfunctional indices (p > 0.05).Conclusion: Patients with the indeterminate form of Chagas disease have both dysautonomia, and left ventricular diastolic dysfunction. However, the right ventricular function is preserved. Importantly, ventricular diastolic dysfunction and dysautonomia. are independent phenomena. (c) 2005 Elsevier B.V.. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: A dor e a disfunção no complexo articular do ombro é comumente encontrada na prática fisioterapêutica. Essas anormalidades musculoesqueléticas estão relacionadas à instabilidade e inadequado funcionamento cinemático, que dependem da integridade dos tecidos musculares. Assim, no sentido de prevenir e reabilitar esses sintomas, o uso da haste oscilatória vem sendo implantado para melhorar os resultados de técnicas cinesioterapêuticas. OBJETIVOS: Analisar a atividade eletromiográfica (EMG) dos músculos que estabilizam a articulação do ombro durante a realização de exercícios com haste oscilatória e haste não-oscilatória. MÉTODOS: Participaram do estudo 12 voluntárias com idade de 20,4±1,9 anos. Os dados EMG foram coletados nos músculos trapézio superior (TrS), trapézio inferior (TrI) e deltoide médio (DM) durante três diferentes exercícios realizados com haste oscilatória e haste não-oscilatória. O sinal EMG foi analisado no domínio do tempo pelo cálculo do Root Mean Square (RMS). Os valores de RMS foram normalizados pelo valor de pico obtido em todas as tentativas por cada músculo. A análise estatística foi feita com os testes ANOVA para medidas repetidas e post-hoc de Bonferroni. RESULTADOS: A atividade EMG dos músculos TrS, TrI e DM foi significativamente maior nos exercícios com haste oscilatória do que com haste não-oscilatória (todos p<0,001). Não foram significativas as diferenças na ativação desses músculos entre os exercícios. CONCLUSÃO: Os resultados do presente estudo indicaram que a haste oscilatória requisitou maior atividade EMG dos músculos do ombro e, assim, pode ser um instrumento útil no treinamento desses músculos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to compare trunk muscle co-activation pattern during exercises using an oscillatory pole. Twelve volunteers participated in this study, in which they performed three different exercises. EMG activity of internal oblique (IO), external oblique (EO), rectus abdominis (RA), multifidus (MU) and iliocostalis lumborum (IL) was collected. The EMG signals were analyzed in time domain (RMS) and muscles activation ratios were computed as follow: anterior-posterior (A/P=RA+EO+IO/MU+IL), MU/IL and OE/OI. The bilateral oscillation of the pole in frontal plane (exercise II) promoted a higher value of MU/IL ratio than unilateral oscillation of the pole in sagital plane (exercise III). Also, the bilateral oscillation of the pole in frontal plane (exercise II) and the unilateral oscillation of the pole in sagital plane (exercise III) caused higher values of the IO/EO than bilateral oscillation of the pole in transversal plane (exercise I). Thus, the exercises II and III required higher activation of trunk stabilizer muscles, being more indicate for training, which aims higher recruitment of these muscles in daily activities.