291 resultados para Subtraction radiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to prospectively study the value of thoracic ultrasound (US) before pleural drainage in children with parapneumonic effusion (PPE). All children hospitalized for PPE, identified by thoracic radiography, underwent US to assess pleural loculation, echogenicity, and pleural fluid quantity. From August 2001 to July 2003, 52 children were examined. US was performed on 48 of these children, of whom 35 received chest tube drainage and 13 only received clinical treatment. US identified 38 patients with free flowing and 10 with loculated pleural fluid. About 25 of the free flowing (65.8%) and 10 (100%) of the loculated patients received chest tube drainage. Echogenicity was anechoic in 13, echoic without septations in 17 and echoic with septations in 18. Chest tube drainage was required in 6 anechoic (46.15%), 14 echoic without septations (82.35%), and 15 echoic with septations (83.33%). Quantity of fluid estimated by US varied from 20 to 860 ml. Effusion volume was higher in patients that were echoic with septations and loculated effusions. Pleural glucose and pH were lower, and LDH was higher in loculated PPE patients. In conclusion, US is an auxiliary exam for determining whether thoracic drainage is needed in parapneumonic effusion; loculated or echoic effusion should be drained, and free anechoic fluid needs further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To study cases of foreign bodies (FB) in the tracheobronchial tree investigating the clinical and radiological FB characteristics, complications and endoscopic and surgical intervention. Medical and radiological records review of all FB aspiration cases treated at S (a) over tilde uo Paulo State University Hospital over the last 30 years. One hundred and sixty-four FB cases were analyzed; 57% were male, 84% of these were under 16 years old. The most common clinical manifestations were coughing (68.3%) and choking (54.9%). The most common FBs were seeds (peanut, bean, maize) and also small metal or plastic objects. Radiography was normal in 21.3%, atelectasis was present in 40.9%, hyperinsufflation in 17.1% and the FB was radio-opaque in 20.7%. FB time in the bronchial tree varied from hours to years. The most serious complications, as fibroatelectasis and difficult resolution pneumonia, were caused by the long time that the FB remained in the bronchial tree. FB extraction was by endoscopy in 89% of cases, while 6% required surgical extraction or resection of destroyed part of lung, and 5% spontaneously eliminated the FB. There was no mortality in this series. Coughing and choking were the commonest clinical findings. Most FBs were dried seeds. Complications were due to delays in diagnosis, and most would not have existed if the doctor had given credence to the history. Radiography can be normal as most FBs are radiotransparent. FB extraction was by endoscopy, but a few cases required surgery and others were spontaneously eliminated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A giant fusiform aneurysm in the posterior cerebral artery (PCA) is rare, as is fenestration of the PCA and basilar apex variation. We describe the angiographic and surgical findings of a giant fusiform aneurysm in the P1-P2 PCA segment associated with PCA bilateral fenestration and superior cerebellar artery double origin.CLINICAL PRESENTATION: A 26-year-old woman presented with a 2-month history of visual blurring. Digital subtraction angiography showed a giant (2.5 cm) fusiform PCA aneurysm in the right P1-P2 segment. The 3-dimensional view showed a caudal fusion pattern from the upper portion of the basilar artery associated with a bilateral long fenestration of the P1 and P2 segments and superior cerebellar artery double origin.INTERVENTION: Surgical trapping of the right P1 -P2 segment, including the posterior communicating artery, was performed by a pretemporal approach. Angiograms performed 3 and 13 months after surgery showed complete aneurysm exclusion, and the PCA was permeated and filled the PCA territory. Clinical follow-up at 14 months showed the patient with no deficits and a return to normal life.CONCLUSION: To our knowledge, this is the first report of a giant fusiform aneurysm of the PCA associated with P1-P2 segment fenestration and other variations of the basilar apex (bilateral superior cerebellar artery duplication and caudal fusion). Comprehension of the embryology and anatomy of the PCA and its related vessels and branches is fundamental to the decision-making process for a PCA aneurysm, especially when parent vessel occlusion is planned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiography (conventional and contrasted - canalography) and audioelectrophysiologic (impedance audiometry) tests were correlated with otitis media in 12 middle ear affected and 12 healthy dogs. When comparing both diagnostic methods, it was found that the reliability in the detection of otitis media in dogs was 100% for the first and 58.3-60.0% for the latter. Thus, it was possible to attest that the impedance audiometry was the most accurate method in the identification of otitis media in dogs when compared with radiographic assessments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was carried out in the experimental facilities of FMVZ/UNESP-Botucatu, with the aim of following-up the development and the incidence of femoral degeneration (FD). A total of 305 one-day-old male broilers were housed in six pens of 5m(2) each. A completely randomized experimental design, with 3 treatments (T1-traditional nutritional density diet; T2-high nutritional density diet) of 3 replicates each was applied. Femoral head of the broilers were submitted to gross examination at 0, 7, 14, 21, 28, 35, and 42 days of aged. At 42 days of age, 60 birds (30 per treatment) were submitted to the Veterinary Hospital of FMVZ to determine bone mineral density by radiography. Birds were then sacrificed for gross examination of the legs, and FD scoring. Five legs per treatment within each FD score were submitted to computed tomography for femur head integrity and bone mineral density. Treatments did not influence FD incidence, and the first gross FD lesions appeared when birds were 28 days old. It was concluded that radiographic optical densitometry and computed tomography are efficient methods to evaluate femoral degeneration, and both techniques expressed the same profile. In addition, using radiographic optical densitometry and computed tomography, these results also allowed us to establish bone mineral density value ranges within each gross FD score. These finding may provide an excellent non-invasive tool to describe femoral degeneration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thoracic radiography of a 3-month-old, female Chinese Shar-pei revealed an esophageal hiatal hernia with stomach, liver, and small intestine displaced into the thorax. Three days after the surgical correction, the dog developed ileal intussusception and was reoperated. Recovery was uncomplicated and the dog was asymptomatic 16 months after surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar as alterações do aparato podotroclear de 22 cavalos da raça Quarto de Milha acometidos pela síndrome do navicular utilizando o acesso transcuneal. Esses equinos foram submetidos ao exame radiográfico e ultrassonográfico. No exame radiográfico foi observado a presença de invaginação sinovial de diferentes tipos, além de calcificação da bursa podotroclear e tendão flexor digital profundo, entesiófitos, osteófitos e alteração do limite córtico-medular. No exame ultrassonográfico observou-se alterações da bursa podotroclear, aderência e irregularidades nos bordos do tendão flexor digital profundo, diminuição do coxim digital, calcificação do ligamento sesamóide distal ímpar e irregularidade da superfície flexora do osso sesamóide distal. Todos os equinos que apresentavam alterações radiográficas também apresentaram alterações no exame ultrassonográfico compatíveis com a síndrome do navicular. O exame ultrassonográfico utilizando o acesso transcuneal foi um método prático e eficiente para avaliação das lesões do aparato podotroclear dos eqüinos, sendo um método complementar ao exame radiográfico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiografia e ultrassonografia foram avaliadas como técnicas no diagnóstico por imagem na ruptura do ligamento cruzado cranial (LCCr) em cães. Vinte e cinco cães foram submetidos à radiografia e ultrassonografia e seus resultados foram comparados aos obtidos por artrotomia (teste padrão ouro). O exame radiográfico diagnosticou corretamente a lesão em 84% (21/25) dos casos, mas 16% (4/25) apresentaram resultado falso-negativo. O exame ultrassonográfico foi capaz de diagnosticar acertadamente 76% (19/25) dos casos, e sugeriu a ruptura do LCCr nos 24% (6/25) restantes, apresentando 100% de resultados positivos. Concluiu-se que a radiografia e a ultrassonografia são ferramentas valiosas para diagnosticar casos de ruptura do LCCr em cães.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Impaction of maxillary canines can be prevented by early intervention in the mixed dentition phase after the correct diagnosis of malocclusion, reducing the complexity of the treatment. This article reports the case of a 10-year-old patient who possessed impacted maxillary canines and, after early extraction of primary canines, had reestablished favorable permanent successors' eruption axis. This 5-year radiographic follow-up study with panoramic radiography shows that this can be used in practice and that an effective control strategy ensures the accuracy in the inclination of the impacted canines. Treatment success is related to early diagnosis and strategic interceptive treatment choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar as decisões de tratamento restaurador de superfícies oclusais, sem cavitação, quando realizadas através dos aspectos clínicos e radiográficos, convencional e digitalizado. Foram examinados, 33 sítios das superfícies oclusais de 30 molares permanentes extraídos, com e sem pigmentação. O plano de tratamento para cada região foi realizado por 5 cirurgiões-dentistas, professores universitários, utilizando dois tipos de exames: exame visual de fotografias e radiografia interproximal convencional (IV + RXC); e exame visual de fotografias e radiografia digitalizada (IV + DIGORA). O padrão de validação para os planos de tratamento foi realizado através do aspecto histológico. A sensibilidade em determinar a não-necessidade de tratamento restaurador foi, em média, tanto para a IV + RXC quanto para a IV + DIGORA, de 0,23. A especificidade foi, em média, de 0,83 e 0,86, para a IV + RXC e IV + DIGORA, respectivamente. Quando comparou-se os planos de tratamento intra-examinadores, não foi encontrada diferença estatisticamente significante à nível de 5%. Baseado nestes dados, pode-se concluir que os métodos radiográficos, convencional e digitalizado, não demonstraram diferenças na efetividade da determinação do plano de tratamento de superfícies oclusais sem cavitação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)