108 resultados para Scanning reference electrode technique
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This work describes an application of a multilayer perceptron neural network technique to correct dome emission effects on longwave atmospheric radiation measurements carried out using an Eppley Precision Infrared Radiometer (PIR) pyrgeometer. It is shown that approximately 7-month-long measurements of dome and case temperatures and meteorological variables available in regular surface stations (global solar radiation, air temperature, and air relative humidity) are enough to train the neural network algorithm and correct the observed longwave radiation for dome temperature effects in surface stations with climates similar to that of the city of São Paulo, Brazil. The network was trained using data from 15 October 2003 to 7 January 2004 and verified using data, not present during the network-training period, from 8 January to 30 April 2004. The longwave radiation values generated by the neural network technique were very similar to the values obtained by Fairall et al., assumed here as the reference approach to correct dome emission effects in PIR pyrgeometers. Compared to the empirical approach the neural network technique is less limited to sensor type and time of day (allows nighttime corrections).
Resumo:
A new, versatile, and simple method for quantitative analysis of zinc, copper, lead, and cadmium in fuel ethanol by anodic stripping voltammetry is described. These metals can be quantified by direct dissolution of fuel ethanol in water and subsequent voltammetric measurement after the accumulation step. A maximum limit of 20% (v/v) ethanol in water solution was obtained for voltammetric measurements without loss of sensitivity for metal species. Chemical and operational optimum conditions were analyzed in this study; the values obtained were pH 2.9, a 4.7-mum thickness mercury film, a 1,000-rpm rotation frequency of the working electrode, and a 600-s pre-concentration time. Voltammetric measurements were obtained using linear scan (LSV), differential pulse (DPV), and square wave (SWV) modes and detection limits were in the range 10(-9)-10(-8) mol L-1 for these metal species. The proposed method was compared with a traditional analytical technique, flame atomic absorption spectrometry (FAAS), for quantification of these metal species in commercial fuel ethanol samples.
Resumo:
The Indanthrene Olive Green B (C.I. Vat Green 3; C.I. 69500), VG3 dye, a vat dye bearing an anthraquinonoid group and a ketonic group, can be detected by differential pulse voltammetry in alkaline solution using glassy carbon electrode. on the adsorbed form the dyes are reduced into three cathodic steps at -0.54 V, -0.65 V and -0.93 V vs Ag/AgCl. The leuco form generated after previous electrolysis at controlled potential of -1 V can be detected by voltammetry due to its reoxidation peak at -0.08 V. An analytical method is proposed for determining the vat dye using modified glassy carbon electrode by electrochemical activation in alkaline medium. Linear relationship was observed between l(Pu) vs concentration from I X 10(-5) mol L-1 to 6.0 X 10(-4) mol L-1. The detection limit was calculated to be 9.3 X 10(-6) mol L-1. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
We report the preparation and characterization of yttria-stabilized zirconia/nickel oxide composites (YSZ/NiO). This composite is the precursor material of the cermet YSZ/Ni, which is used as solid oxide fuel cell anode material. The performance of the anode is strongly dependent on the microstructural properties of the cermet. Therefore, the control of the microstructure of the YSZ/NiO composite is a key step for the fabrication of high-performance anodes. In this study, the composites were prepared by a modified liquid mixture technique. Scanning electron microscopy analysis evidenced the good dispersion of the phases and that NiO nanoparticles are spread over the YSZ surface. Sintered pellets were studied by X-ray diffraction and impedance spectroscopy. The main results show that the composite is comprised of a well-dispersed mixture of the two phases. The electrical conductivity data show that there is a strong dependence of the transport mechanism on the relative composition of phases. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
We have studied the possibility of associating fluorescence microscopy and hematoxylin-eosin staining for the identification of elastic fibers in elastin-rich tissues. Elastic fibers and elastic laminae were consistently identified by the proposed procedure, which revealed itself to be easy and useful for the determination of such structures and their distribution. The fluorescence properties of stained elastic fibers are due to eosin staining as revealed by fluorescence analysis of the dye in solution, with no or only minor contribution by the elastin autofluorescence. The main advantage of this technique resides in the possibility of studying the distribution of elastic fibers in file material without further sectioning and staining. The use of the confocal laser scanning microscope greatly improved the resolution and selectivity of imaging elastic fibers in different tissues. The determination of the three-dimensional distribution and structure of elastic fiber and laminae using the confocal laser scanning microscope was evaluated and also produced excellent results.
Resumo:
This paper describes the construction of an electrode of the second kind, Pt\Hg\Hg-2(Bzt)(2)\graphite, sensitive to benzoate ion (Bzt). The electrode provides a near-Nernstian response (-58.19 mV/decade at 25 degrees C) to benzoate ion in the concentration range 1.11 x 10(-1) to 5.00 x 10(-4) M at pH 7.0 and ionic strength 0.500-3.00M, adjusted with NaClO4. The electrode is easily constructed, shows a fast response time, is low in cost, has excellent response stability, and has a lifetime greater than 24 months. which is much longer than those earlier reported for other systems. A further salient feature of the electrode is that perchlorate does not interfere in its response, which may be advantageous in the analysis of perchloric acid-treated samples. It was applied to the determination of sodium benzoate in some commercial expectorating medicinal syrups using the standard additions method. The results obtained by the proposed procedure compare very favorably with those obtained through the reference method recommended by the United States Pharmacopeia. (C) 1998 Academic Press.
Resumo:
The construction of a flow-through cell incorporating an array of gold microelectrodes is described and its application to flow injection analysis with amperometric detection is presented, Simple modification of almost any conventional integrated circuit chip, used as an inexpensive source of pre-assembled gold micro-wires, leads to the rapid and successful preparation of arrays of 8-48 elements, the polymeric encapsulation material from the top face of the chip is removed by abrasion until the gold micro-mires (used to interconnect the silicon circuit to the external contact pins of the chip) are disrupted and their transversal (elliptical) sections become exposed. Once polished, the flat and smooth top surface of the gold microelectrode-array chip (MEAC) is provided with a spacer and fitted under pressure against an acrylic block with the reference and auxiliary electrodes, to form the electrochemical (thin-layer) flow cell, while the contact pins are plugged into a standard IC socket, This design ensures autonomous electric contact with each electrode and allows fast dismantling for polishing or substitution, the performance of flow cells with MEACs was investigated utilizing the technique of reverse pulse amperometry without oxygen removal, A method was established for the determination of the copper concentration in sugar cane spirit, regulated by law for beverages, Samples from industrial producers and small-scale (alembic) brewers were compared, With a 24 MEAC, a detection limit of 30 mu g I-l of copper (4.7 x 10(-7) mol l(-1) of Cu-II for 100 mu l injections) was calculated, Routine operation was established at a frequency of 60-90 determinations per hour, Intercomparison with atomic absorption spectrometric determinations resulted in excellent agreement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Hydrogen interaction with oxide films grown on iron electrodes at open circuit potential (E-oc) and in the passive region (+0.30 V-ECS) was studied by chronopotentiometry, chronoamperometry and electrochemical impedance spectroscopy techniques. The results were obtained in deaerated 0.3 mol L-1 H3BO3 + 0.075 mol L-1 Na2B4O7 (BB, pH 8.4) solution before, during and after hydrogen permeation. The iron oxide film modification was also investigated by means of in situ X-ray absorption near-edge spectroscopy (XANES) and scanning electrochemical microscopy (SECM) before and during hydrogen permeation. The main conclusion was that the passive film is reduced during the hydrogen diffusion. The hydrogen permeation stabilizes the iron surface at a potential close to the thermodynamic water stability line where hydrogen evolution can occur. The stationary condition required for the determination of the permeation parameters cannot be easily attained on iron surface during hydrogen permeation. Moreover, additional attention must be paid when obtaining the transport parameters using the classical permeation cell. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Susceptibility to several ethanolic extracts of propolis (EEP) concentrations was tested with the population analysis technique in reference strains of Staphylococcus aureus (ATCC 25923) and Escherichia coli (ATCC 35218). The results of these tests showed that all bacteria were killed by EEP concentrations approximately equal or higher (2.0% v/v - S. aureus; 10.0% v/v - E. coli) than the respective minimal inhibitory concentrations (MIC). Regarding the susceptibility to propolis, there was a homogeneity of data with the respective time kill curves showing a clear bactericidal effect during 6 to 9 h of exposition.
Resumo:
Visceral larva migrans (VLM) is a clinical syndrome caused by infection of man by Toxocara spp, the common roundworm of dogs and cats. Tissue migration of larval stages causes illness specially in children. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. After the introduction of the enzyme-linked immunosorbent assay (ELISA) using the larval excretory-secretory antigen of T. canis (TES), the diagnosis specificity was greatly improved although cross-reactivity with other helminths are still being reported. In Brazil, diagnosis is routinely made after absorption of serum samples with Ascaris suum antigens, a nematode antigenicaly related with Ascaris lumbricoides which is a common intestinal nematode of children. In order to identify T. canis antigens that cross react to A. suum antigens we analyzed TES antigen by SDS-PAGE and Western blotting techniques. When we used serum samples from patients suspected of VLM and positive result by ELISA as well as a reference serum sample numerous bands were seen (molecular weight of 210-200 kDa, 116-97 kDa, 55-50 kDa and 35-29 kDa). Among these there is at least one band with molecular weight around 55-66 kDa that seem to be responsible for the cross-reactivity between T. canis and A. suum once it disappears when previous absorption of serum samples with A. suum antigens is performed.