111 resultados para SYNDIOSPECIFIC LIVING POLYMERIZATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern restorative dentistry has been playing an outstanding role lately since composite resins, allied to adhesive systems, have been widely applied on anterior and posterior teeth restorations. The evolution of composite resins has mostly been verified due to the improvement of their aesthetic behavior and the increase in their compressive and abrasive strengths. In spite of these developments, the polymerization shrinkage inherent to the material has been a major deficiency that, so far, has been impossible to avoid. Using a gas pycnometry, this research investigated the polymerization shrinkage of three packable composite resins: Filtek P60 (3M), Prodigy Condensable (Kerr), and SureFil (Dentsply/Caulk), varying the distance from the light source to the surface of the resins (2 mm or 10 mm). The pycnometer Accupyc 1330 (Micromeritics, USA) precisely records helium displacement, allowing fast and reliable measurements of the volume of composite resin immediately before and after polymerization, without interference of temperature or humidity. Results were not found to be statistically different for the three tested resins, either for 2 mm or 10 mm-distance from the light source to the composite surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coptotermes gestroi and Heterotermes tenuis (Isoptera: Rbinotermitidae) are important pests in southeastern Brazil causing serious economic damage. In this study we determined the demographic patterns and foraging activity of these species using mark-release-recapture and the consumption of wooden stakes. Using both the weighted mean and Lincoln index methods, population estimates ranged from ≈ 0.57 to 1.99 million individuals for C. gestroi and from ≈ 0.20 to 1.37 million for H. tenuis. Territory size of the colonies ranged from 172.5 to 5235 m 2 for C. gestroi and from 16 to 40 m 2 for H. tenuis. Our results also indicate that foraging activity was dependent on the minimum temperature; however, the existence of a compensation strategy in the foraging activities may permit foragers to exploit food sources under different environmental conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. 3H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. Aim: The purpose of this study was to investigate, using 3H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins. Materials and Methods: Nine disc-shaped specimens (10 x 1 mm) of each denture base resin (Lucitone 550 and QC 20) were prepared according to the manufacturers' recommendations and stored in distilled water at 37°C for 48 h. The specimens were assigned to 3 groups: 1) post-polymerization in a microwave oven for 3 min at 500 W; 2) post-polymerization in water-bath at 55°C for 60 min; and 3) without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle's medium and incubated at 37°C for 24 h. The cytotoxic effect of the eluates was evaluated by 3H-thymidine incorporation. Results: The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (p<0.05). Compared to the group with no heat treatment, water-bath decreased the cytotoxicity of the denture base acrylic resins. Conclusion: The in vitro cytotoxicity of the tested denture base materials was not influenced by microwave post-polymerization heat treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of post-polymerization treatments (MW-microwave irradiatron and WB-water-bath) on the degree of conversion (DC) of three reline resins (Ufi Gel hard-U, Kooliner-K, and Tokuso Rebase Fast-T) and one denture base resin (Lucitone 550-L), submitted to two polymerization cycles (LS-short and LL-long), was evaluated by using FT-Raman spectroscopy (n = 5). The molecular weight (Mw) of the powder of all materials and of K polymerized specimens (control; MW; and WB; n = 3) was analyzed using GPC. DC data were analyzed using Kruskal-Wallis test (α = .05). For control specimens, there were no significant differences between U (68%) and LL (77%) and among LL, K (81%), and T (84%). LS (92%) had the highest DC (P<0.05). Only material K exhibited an increased DC after WB (P<0.05). All powders had Mw from 4.0 × 105 to 6.5 × 105 and narrow Mw distributions (2.1 to 3.6). Polymerization and post-polymerization produced K specimens with Mw similar to that of K powder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many prokaryotic nucleoid proteins bend DNA and form extended helical protein-DNA fibers rather than condensed structures. On the other hand, it is known that such proteins (such as bacterial HU) strongly promote DNA condensation by macromolecular crowding. Using theoretical arguments, we show that this synergy is a simple consequence of the larger diameter and lower net charge density of the protein-DNA filaments as compared to naked DNA, and hence, should be quite general. To illustrate this generality, we use light-scattering to show that the 7kDa basic archaeal nucleoid protein Sso7d from Sulfolobus solfataricus (known to sharply bend DNA) likewise does not significantly condense DNA by itself. However, the resulting protein-DNA fibers are again highly susceptible to crowding-induced condensation. Clearly, if DNA-bending nucleoid proteins fail to condense DNA in dilute solution, this does not mean that they do not contribute to DNA condensation in the context of the crowded living cell. © 2007 World Scientific Publishing Company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of water-bath and microwave post-polymerization treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II-D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard C-UGH) and one heat-polymerized acrylic resin (Lucitone 550-L), processed using two polymerization cycles (short cycle - 90 minutes at 73°C and 100°C for 30 minutes; and long cycle - 9 hours at 71°C). For each material, thirty specimens (64 x 10 x 3.3 mm) were made and divided into 3 groups (n=10). Specimens were tested after: processing (control group); water-bath at 55°C for 10 minutes (reline materials) or 60 minutes (L); and microwave irradiation. Flexural strength tests were performed at a crosshead speed of 5 mm/min using a three-point bending device with a span of 50 mm. The flexural strengths values were calculated in MPa. One fragment of each specimen was submitted to Vickers hardness test. Data were analyzed by 2-way ANOVA followed by Tukey's HSD test (α=0.05). L microwaved specimens (short cycle) exhibited significantly higher flexural strength means than its respective control group (p<0.05). Water-bath promoted a significant increase (p<0.05) in flexural strength of K and L (long cycle). The hardness of the tested materials was not influenced by the post-polymerization treatments. Post-polymerization treatments could be used to improve the flexural strength of some materials tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the influence of polymerization cycle and thickness of maxillary complete denture bases on the porosity of acrylic resin. Materials and Methods: Two heat-activated denture base resins - one conventional (Clássico) and one designed for microwave polymerization (Onda-Cryl) - were used. Four groups were established, according to polymerization cycles: A (Onda-Cryl, short microwave cycle), B (Onda-Cryl, long microwave cycle), C (Onda-Cryl, manufacturing microwave cycle), and T (Clássico, water bath). Porosity was evaluated for different thicknesses (2.0, 3.5, and 5.0 mm; thicknesses I, II, and III, respectively) by measurement of the specimen volume before and after its immersion in water. The percent porosity data were submitted to Kruskal-Wallis for comparison among the groups. Results: The Kruskal-Wallis test detected that the combinations of the different cycles and thicknesses showed significant differences, and the mean ranks of percent porosity showed differences only in the thinnest (2.0 mm) microwave-polymerized specimens (A = 53.55, B = 40.80, and C = 90.70). Thickness did not affect the results for cycle T (I = 96.15, II = 70.20, and III = 82.70), because porosity values were similar in the three thicknesses. Conclusions: Microwave polymerization cycles and the specimen thickness of acrylic resin influenced porosity. Porosity differences were not observed in the polymerized resin bases in the water bath cycle for any thickness. © 2007 by The American College of Prosthodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: This study evaluated the temperature rise of the adhesive system Single Bond (SB) and the composite resins Filtek Z350 flow (Z) and Filtek Supreme (S), when polymerized by light-emitting diode (LED XL 3000) and quartz-tungsten halogen (QTH Biolux). METHODS: Class V cavities (3 yen2 mm) were prepared in 80 bovine incisors under standardized conditions. The patients were divided as follows: G1: Control; G2: SB; G3: SB + Z; G4: SB + S. The groups were subdivided into two groups for polymerization (A: QTH, B: LED). Light curing was performed for 40 s and measurement of temperature changes during polymerization was performed with a thermocouple positioned inside the pulp chamber. Data were statistically analyzed using ANOVA and Tukey tests. RESULTS: The factors material (P<0.00001) and curing unit (P<0.00001) had significant influence on temperature rise. The lowest temperature increase (0.15 degrees C) was recorded in G2 B and the highest was induced in G1 A (0.75 degrees C, P<0.05). In all groups, lower pulp chamber temperature measurements were obtained when using LED compared to QTH (P<0.05). CONCLUSION: QTH caused greater increases in tooth temperature than LED. However, both sources did not increase pulpal temperature above the critical value that may cause pulpal damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The level of high-density lipoprotein is thought to be critical in inhibiting lesion formation as well as reducing the lipid load of preexisting atherosclerotic lesions. With the aim of determining the main determinants of plasma HDL-cholesterol (HDL-c) in free-living adults, 997 individuals (52.3 10 years, 67 females) were selected for a descriptive cross-sectional study. The used data corresponded to the baseline obtained from participants clinically selected for a lifestyle modification program. Covariables of clinical, anthropometry, food intake, aerobic fitness, and plasma biochemistry were analyzed against plasma HDL-c either as continuous or categorized variables. After adjustments for age, gender, and BMI the excess of abdominal fat along with high carbohydrate-energy intake and altered plasma triglycerides were the stronger predictors of reduced plasma HDL-c. In conclusion lifestyle interventions aiming to normalize abdominal fatness and plasma triglycerides are recommended to restore normal levels of HDL-c in these free-living adults. Copyright © 2011 Erick Prado de Oliveira et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cellulose nanofibrils (CNF) were extracted by acid hydrolysis from cotton microfibrils and nanocomposites with polyaniline doped with dodecyl benzenesulphonic acid (PANI-DBSA) were obtained by in situ polymerization of aniline onto CNF. The ratios between DBSA to aniline and aniline to oxidant were varied in situ and the nanocomposites characterized by four probe DC electrical conductivity, ultraviolet-visible-near infrared (UV-Vis - NIR) and Fourier-transform infrared (FTIR) spectroscopies and X-ray diffraction (XRD). FTIR and UV-Vis/NIR characterization confirmed the polymerization of PANI onto CNF surfaces. Electrical conductivity of about 10 -1 S/cm was achieved for the composites; conductivity was mostly independent of DBSA/aniline (between 2 and 4) and aniline/oxidant (between 1 and 5) molar ratios. X-ray patterns of the samples showed crystalline peaks characteristic of cellulose I for CNF samples, and a mixture of both characteristic peaks of PANI and CNF for the nanocomposites. Field emission scanning electron microscopy (FESEM) characterization corroborated the abovementioned results showing that PANI coated the surface of the nanofibrils. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate a simple molecular method of reverse transcriptase polymerase chain reaction (RT-PCR) to differentiate Newcastle disease virus strains according to their pathogenicity, in order to use it in molecular screening of Newcastle disease virus in poultry and free-living bird populations. Specific primers were developed to differentiate LaSota-LS-(vaccine strain) and Sao Joao do Meriti-SJM-strain (highly pathogenic strain). Chickens and pigeons were experimentally vaccinated/infected for an in vivo study to determine virus shedding in feces. Validation of sensitivity and specificity of the primers (SJM and LS) by experimental models used in the present study and results obtained in the molecular analysis of the primers by BLAST made it possible to generalize results. The development of primers that differentiate the level of pathogenicity of NDV stains is very important, mainly in countries where real-time RT-PCR is still not used as a routine test. These primers were able to determine the presence of the agent and to differentiate it according to its pathogenicity. © 2012 Springer Science+Business Media B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Metabolic and morphological changes associated with excessive abdominal fat, after the introduction of Antiretroviral Therapy, increase the risk of cardiovascular disease in people living with HIV/AIDS(PLWHA). Accurate methods for body composition analysis are expensive and the use of anthropometric indices is an alternative. However the investigations about this subject in PLWHA are rare, making this research very important for clinical purpose and to advance scientific knowledge. The aim of this study is to correlate results of anthropometric indices of evaluation of body fat distribution with the results obtained by Dual-energy X-Ray Absorptiometry(DEXA) , in people living with HIV/AIDS. Methods. The sample was of 67 PLWHA(39 male and 28 female), aged 43.6+7.9 years. Body mass index, conicity index, waist/hip ratio, waist/height ratio and waist/thigh were calculated. Separated by sex, each index/ratio was plotted in a scatter chart with linear regression fit and their respective Pearson correlation coefficients. Analyses were performed using Prism statistical program and significance was set at 5%. Results: The waist/height ratio presented the highest correlation coefficient, for both male (r=0.80, p<0.001) and female (r=0.87, p <001), while the lowest were in the waist/thigh also for both: male group (r=0.58, p<0.001) and female group (r=0.03, p=0.86). The other indices also showed significant positive correlation with DEXA. Conclusion: Anthropometric indices, especially waist/height ratio may be a good alternative way to be used for evaluating the distribution of fat in the abdominal region of adults living with HIV/ADIS. © 2012 Segatto et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the safety of living kidney donation has been well established, prospective studies examining the physical and psychosocial aspects of the donor's quality of life are still scarce. Thus, the purpose of this prospective work was to assess the quality of life of 50 consecutive donors before and after kidney transplantation. All donors were asked to respond to both a donor questionnaire and the short-form 36-item health survey (SF-36). Interviews were individually conducted before, three months after, and over one yr after transplantation. Donation was considered a positive experience by all patients and had no impact on any physical or psychosocial aspect of the donor's life. Improved self-esteem and better quality of life after donation were reported in 52% of the cases. All donors would donate again and encouraged donation. SF-36 data indicated improvement in post-donation mental and physical scores among living donors closely related to recipient. Overall, most donors had a positive experience, felt no changes in quality of life, experienced enhanced self-esteem, would donate again, and recommended donation. © 2012 John Wiley & Sons A/S.