77 resultados para Refração


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the past few years several GPS (Global Position System) positioning techniques have been develope and/or improved with the goal of obtaining high accuracy and productivity in real time. The reference station network concept besides to enabling quality and reliability in positioning for scientific and civil GPS community, allows studies concerning tropospheric refraction modeling in the network region. Moreover, among the network corrections transmission methods available to users, there is the VRS (Virtual Reference Station) concept. In this method, the data of a virtual station are generated near the rover receiver (user). This provides a short baseline and the user has the possibility of using a single frequency receiver to accomplish the relative positioning. In this paper, the methodology applied to generate VRS data, using different tropospheric models is described. Thus, comparative tests were conducted in the four seasons with the NWP/INPE (Numerical Weather Prediction/National Institute for Space Research) and Hopfield tropospheric models. In order to analyse the VRS data quality, it was used the Precise Point Positioning (PPP) method, where satisfactory results were found. Mean differences between PNT/INPE and Hopfield models of 9.75% and 24.2% for the hydrostatic and wet days, respectively were obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optics consists in the study of interaction of light with physical systems. The human vision is a product of the interaction of light with the eye (a very peculiar physical system). Here we present a basic study of the relationship between the optics and human vision, including: - The fundaments and physicals properties who characterize the light and the colors and the characteristics of the incidence mediums. - The basics laws of geometrical optics, based in the rectilinear propagation of light in the form of a light ray, in the independence of light rays and in the principle of reversibility of the light beams. This principle is present in the process of image formations in lenses and mirrors and applied in the study of image formation in the human eye. - The refraction and reflection laws and types of lenses, who permits the construction of optics devices for the study of physical universe, and the appliances to correct vision diseases. - Presents the human vision process as consisting in the reception of light (electromagnetic radiation in the zone of wavelength visible to us) through the eye and the sending of information obtained by the retina to the brain where it is interpreted. The vision involves a biophysical relation between the light and the biological structure of the eye who is constituted by cornea, iris, crystalline and retina. Analyzes is made of how some parts of the eye performs a function in the reception and sending of information of the images to the brain

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin polymeric films deposited by plasma are very atractive for many industrial and scientific applications, in areas such as electronics, mechanics, coatings, biomaterials, among others, due to its favorable properties such as good adhesion to the substrate, high crosslinking, nanomectric thickness, homogeneity, etc. In this work, thin films were deposited by plasma immersion ion implantation and deposition technique from a hexamethyldisilazane/argon mixture at different proportions. These films were subjected to several characterizations, such as, contact angle, which presented values near to 100 degrees, surface energy, with values near to 31 mJ/m2, hardness with values between 0.7 and 2.6 GPa, thickness from 100 to 200 nm, refractive index from 1.56 to 1.64, molecular structure presenting the following functional groups in the infrared spectra region: CHx from 2960 to 2900 cm-1; Si-H around 2130 cm-1; CH3 in Si-(CH3)x around 1410 cm-1; CH3 in Si-(CH3)x in 1260 cm-1; N-H around 1180 cm-1; CH2 in Si-CH2-Si bonds around 1025 cm-1; Si-O in Si-O-Si from 1020 to 1100 cm-1; Si-N in Si-H-Si bonds around 940 cm-1; CH3 in Si-(CH3)3 in 850 cm-1; Si-C bonds in Si-(CH3)2 around 800 cm-1; and Si-H in 680 cm-1 . From these characterizations, it was possible to conclude that the concentration of argon or hexamethyldisilazane in the mixture changed the resulting polymer

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents experimental results of some physical properties of antimony phosphate glasses with compositions (x) Sb2O3 - (1-x) P2O5 (x = 0.75, 0.85, 0.90). Mechanical, thermal, optical and electrical properties were investigated: density, elastic moduli (Young's moduli and Poisson's ratio), Vickers microhardness, coefficient of thermal expansion, glass transition temperature, refractive index and electrical conductivity (for x = 0.75). There was no evidence of electronic conductivity by bipolaron hopping. Measurements of energy dispersive spectroscopy (EDS) showed that volatilization of Sb2O3 takes place during the glass melting

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A psoríase é uma doença inflamatória de pele e das articulações, e por acometer um órgão visível como a pele, resulta em transtornos psicológicos relacionados à auto-estima do paciente. Dentre os fármacos empregados no tratamento, destaca-se o metotrexato para uso sistêmico que, embora eficiente, possui a desvantagem de causar efeitos colaterais tóxicos como a hepatotoxicidade e a mielotoxicidade. Para minimizar tais efeitos e aumentar a eficácia do fármaco, o trabalho teve por objetivo desenvolver e caracterizar sistemas nanoestruturados para administração cutânea do metotrexato. Para realizar esse estudo, inicialmente foram preparadas diferentes formulações constituídas por silicone fluido de copolímero glicol (DC® 193), poliéter funcional siloxano (DC® 5329) e água destilada. O metotrexato foi incorporado numa concentração de 1,25% (p/v), com auxílio de solução de hidróxido de sódio 1M, sendo ajustado o pH final da formulação para 7,0 com ácido clorídrico 0,1M. Foram selecionadas algumas regiões do diagrama para serem submetidas a testes de estabilidade, empregando o teste de centrifugação, determinação do pH, condutividade iônica, índice de refração e avaliação das características organolépticas. Foi realizada a análise reológica empregando reômetro, modelo RS-1 (HaakeRheostress). As estruturas das formulações foram analisadas por microscopia de luz polarizada. As amostras com maior concentração de tensoativo apresentaram aspecto transparente, sendo submetidas à análise com microscópio de luz polarizada, onde evidenciou-se estruturas conhecidas como “cruzes de malta”, indicativas de fase lamelar. Foram selecionadas 3 formulações com concentração de 40% de tensoativo, variando-se as proporções de água e óleo, nas quais foram incorporadas o metotrexato... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The X-ray fluorescence analysis (XRF) is an important technique for the qualitative and quantitative determination of chemical components in a sample. It is based on measurement of the intensity of the emitted characteristic radiation by the elements of the sample, after being properly excited. One of the modalities of this technique is the total reflection x-ray fluorescence (TXRF). In TXRF, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample-support interface. Thus, there is a minimum angle of incidence that there is no refracted beam and all the incident radiation undergoes total reflection. As it is implemented in very small samples, in a film format, self-absorption effects should not very relevant. In this study, we evaluated the feasibility of using code MCNPX (Monte Carlo N - Particle eXtended), to simulate a measure implemented by the TXRF technique. In this way, it was verified the quality of response of a system by TXRF spectroscopy using synchrotron radiation as excitation beam for a simple setup, by retrieving the characteristic energies and the concentrations of the elements in the sample. The steps of data processing, after obtaining the excitation spectra, were the same as in a real experiment and included the obtaining of the sensitivity curve for the simulated system. The agreement between the theoretical and simulated values of Ka characteristic energies for different elements was lower than 1 % .The obtained concentration of the elements of the sample had high relatively errors ( between 6 and 60 % ) due mainly to lack of knowing about some realistic physical parameters of the sample , such as density . In this way, this result does not preclude the use of MCNPX code for this type of application

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)