93 resultados para Razão isotópica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Direito - FCHS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of the mechanical properties of nickel-titanium (NiTi) termoactives of the more accessible of the domestic market is still limited. Given this, the objective of this study was to evaluate and compare through deflection tests in brackets NiTi wires 03 term rectangular gauge 0.014 '' enabled x 0.025 '' and 0.016 '' x 0.022 '' of different brands (MORELLI (R), ORMCO (R) ORTHOSOURCE (R), ORTHOMETRIC (R), EURODONTO (R) and ADITEK (R)). All tests were carried out on universal testing machine EMIC DL 2000 under identical conditions and controlled at a temperature of 36 degrees C +/- 0.5 degrees C. Five measurements (N= 5) were performed for each thickness/wire tag that was deflected up to a limit of 4.0mm at a speed of 1.0mm/min. Each 0.2mm (round trip) of corresponding strength measured deflection for the construction of the graph of force x deflection at Tesc program version 3.04. Each graphic was evaluated according to the following variables: beginning of the Martensitic transformation (cN and mm), maximum strength (cN), the beginning and end of the plateau of deactivation (cN and mm) and length (mm) plateau. The average and standard deviation were calculated for all variables and statistical analysis was made by ANOVA tests 2 criteria and Turkey or Kruskal-Wallis and Dunn, a 5% level of significance. The results showed that the tests of 0.014 '' x0.025 '' ORTHOMETRIC (R) brands and ORMCO (R) showed the best results, as well as the wires of the MORELLI (R) and ORTHOSOURCE (R) to wires 0.016 '' x0.022 ''. In General, the gauge wires 0.014 '' x0.025 '' showed strength levels on the plateau of deactivation to 6 x smaller than 0.016 '' x0.022 '' caliber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FMVZ

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since discovery, computed tomography is a widely used diagnostic modality. However, this modality imparts relatively high doses to the patients and with fast technological advancement, it is necessary optimize the doses used and ensure the quality of the images through a quality assurance program. This work intended to compare Computed Tomography Dose Index (CTDIW) and effective dose with components of image quality: the Contrast-to-Noise Ratio (CNR) and Signal-to-Noise Ratio (SNR), and a quality factor (Q) deduced by the Rose model for two groups of computed tomography units. The first group was composed by equipments with 10 up to 16 slices and the second one presented 40 up to 320 slices detectors, for the protocols of head and abdomen. It was realized a comparison between different selectable parameters in the protocol of a Philips Brilliance 16, too. The results of the first group to CTDIW, effective dose, SNR and CNR showed variations of 28%, 33%, 37% and 32% respectively for head protocol, and 21%, 27%, 43% and 37% respectively for abdomen protocol. The results of the group 2 to CTDIW, effective dose, SNR and CNR showed variations of 15%, 26%, 36% and 34% respectively for the head protocol, and 8%, 13%, 50% and 60% respectively for abdomen protocol. The comparison between both groups demonstrated similar levels of doses impartation to patients though having so many different configurations, if the uncertainties associated with this measurement were considered. The results of the comparison between different parameters in the Philips Brilliance 16 scanner were in agreement with expected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The signal-to-noise ratio and image uniformity analysis parameters are very important in quality control of an MRI scanner. They are measured in regular tests with phantoms. In these tests, however, used to quadrature coil, which has been most widely used clinically, and, therefore, was replaced in the procedures for body coil. In order to understand the difference between these two parameters in these coils, the study aimed to analyze the images acquired from four different phantoms in the same equipment under the same conditions for comparison purposes. With these results, it can be concluded that the body coil signal-to-noise ratio has always smaller than the quadrature in any projection, whereas the image uniformity is larger

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ankle sprains represent the most common injuries in sports and basketball. In this sense, the use of ankle bracing and strength capacity analysis of the ankle evertor and invertor muscles, have been suggested as preventive measures and important tools for identifying risk factors associated with ankle sprains. However, questions still persist as to effect of the use ankle bracing on biomechanical variables related to the stability of the ankle. For this reason, this study aims to analyze the effect of the use of ankle bracing on peak torque (PT) of ankle evertor and invertor muscles and on eccentric evertor/concentric invertor torque ratio (EVEECC/INVCON), during the basketball match-play simulation. Ten healthy college basketball players, without mechanics or functional ankle instability performed a laboratory-based protocol representative of work rates observed during basketball match-play, in two different situations, with and without use of ankle bracing. The test was composed of a succession of intermittent physical effort equally distributed in four periods of 10 minutes each, considering the mechanical and physiological demands of a basketball match-play. Prior to the start of the trial (Evaluation 1) and after 2° (Evaluation 2) and 4° (Evaluation 3) periods, the subjects performed five maximal isokinetic concentric and eccentric contractions of ankle invertor and evertor muscles, separated by two minutes rest, at 60 °/s and 120 °/s. After testing for normality of data distribution with the Shapiro-Wilk test, was used the ANOVA repeated measures for two factors and post-hoc Bonferroni test for comparison of variables between assessments. Was adopted p < 0.05. There was no significant difference for PT and EVEECC/INVCON torque ratio between assessments. There was a decrease in PT EVEECC at 60º/s and 120º/s for the ...(Complete abstract click electronic access below)