86 resultados para Randomized controlled clinical trial
Resumo:
Objective: The aim of this study was to evaluate the 2-year clinical performance of class II restorations made with a composite resin with two different viscosities.Methods: 47 patients received two class II restorations (n = 94), one made with GrandioSO (conventional viscosity CV), and the other with GrandioSO Heavy Flow (flowable viscosity FV), subjecting both materials to the same clinical conditions. The self-etching adhesive Futurabond M was used for all restorations. The composites were inserted using the incremental technique. The restorations were evaluated using the modified USPHS criteria according to the periods: baseline, 6 months, 1 year and 2 years after restorative procedures.Results: After 24 months, 40 patients attended the recall and 78 restorations were evaluated. In all periods, no secondary caries was observed. After 6 months, there were slightly overall changes of scores for most parameters. After 24 months, the higher number of changes from score Alfa to Bravo was observed for marginal discolouration (32.5% CV and 39.5% FV) and colour match (15% CV and 31.6% FV), followed by proximal contact (25% CV and 23.7% FV) and marginal adaptation (20% CV and 21.1% FV). For wear, surface texture and postoperative sensitivity the changes were very small. Just two restorations were lost during the 24-month follow up. Less than 5% of all restorations showed postoperative sensitivity. Chi-square test showed no significant differences between the two materials for all parameters analysed.Conclusion: After 2 years of clinical service, no significant differences were observed between GrandioSO conventional and GrandioSO Heavy Flow for the parameters analysed. Both materials provided acceptable clinical behaviour in class II restorations. Clinical Significance: This study presents the possibility of using a flowable composite with high filler content, for performing class II restorations. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To investigate the effects of elastic tubing training compared with conventional resistance training on the improvement of functional exercise capacity, muscle strength, fat-free mass, and systemic inflammation in patients with chronic obstructive pulmonary disease.Design: A prospective, randomized, eight-week clinical trial.Setting: The study was conducted in a university-based, outpatient, physical therapy clinic.Subjects: A total of 49 patients with moderate chronic obstructive pulmonary disease.Interventions: Participants were randomly assigned to perform elastic tubing training or conventional resistance training three times per week for eight weeks.Main measures: The primary outcome measure was functional exercise capacity. The secondary outcome measures were peripheral muscle strength, health-related quality of life assessed by the Chronic Respiratory Disease Questionnaire (CRDQ), fat-free mass, and cytokine profile.Results: After eight weeks, the mean distance covered during six minutes increased by 73 meters (69) in the elastic tubing group and by 42 meters (+/- 59) in the conventional group (p < 0.05). The muscle strength and quality of life improved in both groups (P < 0.05), with no significant differences between the groups. There was a trend toward an improved fat-free mass in both groups (P = 0.05). After the first and last sessions, there was an increase in interleukin 1 (IL-1) and interleukin 10 (IL-10) in both groups, while tumour necrosis factor alpha (TNF-) was stimulated only in the conventional training group.Conclusion: Elastic tubing training had a greater effect on functional exercise capacity than conventional resistance training. Both interventions were equally effective in improving muscle strength and quality of life.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Statement of problem Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. Purpose The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Material and methods Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). Results A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (P<.001). No significant difference was found between the 2 denture adhesives evaluated. Conclusion The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive.
Resumo:
Prolonged intermittent renal replacement therapy (PIRRT) has emerged as an alternative to continuous renal replacement therapy in the management of acute kidney injury (AKI) patients. This trial aimed to compare the dialysis complications occurring during different durations of PIRRT sessions in critically ill AKI patients. We included patients older than 18 years with AKI associated with sepsis admitted to the intensive care unit and using noradrenaline doses ranging from 0.3 to 0.7 mu g/kg/min. Patients were divided into two groups randomly: in G1, 6-h sessions were performed, and in G2, 10-h sessions were performed. Seventy-five patients were treated with 195 PIRRT sessions for 18 consecutive months. The prevalence of hypotension, filter clotting, hypokalemia, and hypophosphatemia was 82.6, 25.3, 20, and 10.6%, respectively. G1 was composed of 38 patients treated with 100 sessions, whereas G2 consisted of 37 patients treated with 95 sessions. G1 and G2 were similar in male predominance (65.7 vs. 75.6%, P=0.34), age (63.6 +/- 14 vs. 59.9 +/- 15.5 years, P=0.28) and Sequential Organ Failure Assessment score (SOFA; 13.1 +/- 2.4 vs. 14.2 +/- 3.0, P=0.2). There was no significant difference between the two groups in hypotension (81.5 vs. 83.7%, P=0.8), filter clotting (23.6 vs. 27%, P=0.73), hypokalemia (13.1 vs. 8.1%, P=0.71), and hypophosphatemia (18.4 vs. 21.6%, P=0.72). However, the group treated with sessions of 10h were refractory to clinical measures for hypotension, and dialysis sessions were interrupted more often (9.5 vs. 30.1%, P=0.03). Metabolic control and fluid balance were similar between G1 and G2 (blood urea nitrogen [BUN]: 81 +/- 30 vs. 73 +/- 33mg/dL, P=1.0; delivered Kt/V: 1.09 +/- 0.24 vs. 1.26 +/- 0.26, P=0.09; actual ultrafiltration: 1731 +/- 818 vs. 2332 +/- 947mL, P=0.13) and fluid balance (-731 +/- 125 vs. -652 +/- 141mL, respectively) . In conclusion, intradialysis hypotension was common in AKI patients treated with PIRRT. There was no difference in the prevalence of dialysis complications in patients undergoing different durations of PIRRT.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Solid-organ transplant recipients present a high rate of non-adherence to drug treatment. Few interventional studies have included approaches aimed at increasing adherence. The objective of this study was to evaluate the impact of an educational and behavioral strategy on treatment adherence of kidney transplant recipients. In a randomized prospective study, incident renal transplant patients (n = 111) were divided into two groups: control group (received usual transplant patient education) and treatment group (usual transplant patient education plus ten additional weekly 30-min education/counseling sessions about immunosuppressive drugs and behavioral changes). Treatment adherence was assessed using ITAS adherence questionnaire after 3 months. Renal function at 3, 6, and 12 months, and the incidence of transplant rejection were evaluated. The non-adherence rates were 46.4 and 14.5 % in the control and treatment groups (p = 0.001), respectively. The relative risk for non-adherence was 2.59 times (CI 1.38-4.88) higher in the control group. Multivariate analysis demonstrated a 5.84 times (CI 1.8-18.8, p = 0.003) higher risk of non-adherence in the control group. There were no differences in renal function and rejection rates between groups. A behavioral and educational strategy addressing the patient's perceptions and knowledge about the anti-rejection drugs significantly improved the short-term adherence to immunosuppressive therapy.
Resumo:
The aim of this clinical randomized double-blind split-mouth study was to assess the effectiveness of a 6% hydrogen peroxide with nitrogen-doped titanium dioxide light activated bleaching agent. 31 patients were treated with: one upper hemiarcade with a 35% hydrogen peroxide bleaching agent and the other hemiarcade with a 6% hydrogen peroxide. Two applications were completed each treatment session and three sessions were appointed, with one week interval between them. Tooth colour was registered each session and 1 week and 1 months after completing the treatment by spectrophotometer, registering parameters L*, a* and b*, and subjectively using VITA Classic guide. Tooth sensitivity was registered by VAS and patient satisfaction and self-perception result was determined using OHIP-14. Tooth colour variation and sensitivity were compared between both bleaching agents. Both treatment showed a change between baseline colour and all check-points with a ΔE=5.57 for 6% and of ΔE=7.98 for the 35% one month after completing the (p<0.05). No statistical differences were seen when subjective evaluations were compared. Also, no differences were seen in tooth sensitivity between bleaching agents. OHIP-14 questionnaire demonstrated a significant change for all patients after bleaching. A 6% hydrogen peroxide with nitrogen-doped titanium dioxide light activated agent is effective for tooth bleaching, reaching a ΔE of 5.57 one month after completing the treatment, with no clinical differences to a 35% agent neither in colour change or in tooth sensitivity. A low concentration hydrogen peroxide bleaching agent may reach good clinical results with less adverse effects.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Studies have investigated the influence of neuromuscular electrostimulation on the exercise/muscle capacity of patients with heart failure (HF), but the hemodynamic overload has never been investigated. The aim of our study was to evaluate the heart rate (HR), systolic and diastolic blood pressures in one session of strength exercises with and without neuromuscular electrostimulation (quadriceps) in HF patients and in healthy subjects. Methods: Ten (50% male) HF patients and healthy subjects performed three sets of eight repetitions with and without neuromuscular electrostimulation randomly, with one week between sessions. Throughout, electromyography was performed to guarantee the electrostimulation was effective. The hemodynamic variables were measured at rest, again immediately after the end of each set of exercises, and during the recovery period. Results: Systolic and diastolic blood pressures did not change during each set of exercises among either the HF patients or the controls. Without electrostimulation: among the controls, the HR corresponding to the first (85 ± 13 bpm, p = 0.002), second (84 ± 10 bpm, p < 0.001), third (89 ± 17, p < 0.001) sets and recuperation (83 ± 16 bpm, p = 0.012) were different compared to the resting HR (77 bpm). Moreover, the recuperation was different to the third set (0.018). Among HF patients, the HR corresponding to the first (84 ± 9 bpm, p = 0.041) and third (84 ± 10 bpm, p = 0.036) sets were different compared to the resting HR (80 ± 7 bpm), but this increase of 4 bpm is clinically irrelevant to HF. With electrostimulation: among the controls, the HR corresponding to the third set (84 ± 9 bpm) was different compared to the resting HR (80 ± 7 bmp, p = 0.016). Among HF patients, there were no statistical differences between the sets. The procedure was well tolerated and no subjects reported muscle pain after 24 hours. Conclusions: One session of strength exercises with and without neuromuscular electrostimulation does not promote a hemodynamic overload in HF patients. (Cardiol J 2011; 18, 1: 39-46)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)