78 resultados para Qualidade da agua : Drenagem
Resumo:
The work is to study about the quality of surface waters of the Piaguí and neighborhoods Colonia Santa Luzia. Six samples of which the physical, chemical and biological parameters were analyzed were collected. The tests were conducted in accordance with Standard Methods for the Examination of Water and Wastewater 20th edition and compared with the resolution of CONAMA No. 357 (2005). Critical parameters are found in fecal coliform and water coloring, which may indicate an anthropogenic interference in the sampling points (domestic sewage), or the effect of rainfall during the collection period influence the results
Resumo:
água que abastece uma cidade se não for tratada pode tornar-se importante veículo de transmissores de doenças. O controle da qualidade é uma medida que visa, principalmente, garantir a saúde da população. O objetivo desta pesquisa foi avaliar a qualidade da água distribuída pelo sistema de abastecimento da cidade de Santa Lúcia – SP. A água proveniente desse sistema chega até as residências e, muitas vezes, é consumida sem nenhum tratamento doméstico complementar. A cidade de Santa Lúcia é abastecida por três poços profundos (P2, P3, e P4). Com o intuito de avaliar a qualidade da água captada desses poços e distribuídas para consumo humano foram coletadas amostras diretamente dos poços e de um ponto de consumo nas áreas abastecidas por cada poço. Foram feitas três coletas em cada ponto, em três diferentes épocas do ano. Realizaram-se análises físico-químicas e bacteriológicas em todas as amostras. As análises bacteriológicas foram feitas para determinação da presença de coliformes totais, E. coli e contagem padrão de bactérias heterotróficas em placa. As análises físico-químicas avaliaram cloro residual livre, fluoreto, turbidez, pH, cor aparente e sólidos totais dissolvidos. Duas amostras foram positivas para coliformes totais, apenas uma amostra coletada no poço 2 foi positiva para E. coli. Para bactérias heterotróficas todas a amostras apresentaram contagem em placa inferior a 500 UFC/mL. Todas as amostras estavam dentro do padrão determinado pela legislação para pH, turbidez e sólidos totais dissolvidos. Todas as amostras coletadas no poço 2 tiveram como resultado ausência de cloro residual livre, o mesmo resultado para os demais pontos na segunda coleta de amostras. Todas as amostras apresentaram fluoreto com valores abaixo do VMP estabelecido pela legislação brasileira porém apenas cinco com concentrações dentro da faixa estabelecida pela legislação do Estado de São Paulo ...
Resumo:
Pós-graduação em Geografia - FCT
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
This paper reports the results of an extension project carried out at Unesp/Veterinary Medicine course in Araçatuba city with milk farmers of the region. The aim of the project was to supply information to farmers concerning to good quality milk production and, at the same time, to follow up the evolution of milk quality parameters, according to the current Brazilian legislation. Every 45 days, approximately, lectures were presented to milk farmers in Araçatuba city region, approaching chemical and microbiological composition of milk, prevention and detection of mastitis, hygiene proceedings in milking and conservation of milk, cleaning and sanitization operations of facilities and equipments and prevention of adulteration. During the intervals between lectures, milk samples were collected from collective milk cooling tanks and analyzed for microbiological, hygienic and physicochemical tests. The main inadequacies in milk quality were high total bacteria and somatic cells counts, low solids contents and water addition. These problems did not proceed to betterment during the project time. So, it was concluded that the time for instruction of farmers was not enough for a progress in the quality of the milk produced in the region, pointing out the need in continuing this kind of work.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The management of urban areas must consider aspects related to urban drainage, especially in hot and humid environments, and such aspects must be incorporated on director plans. This is quite important in urban areas settled on natural fragile hydro-geomorphologic areas. So, the main aim of this paper was to present the urban drainage diagnostic made in Rio Claro (SP-Brazil), discussing its results and evaluating the applied techniques. Further, there were presented some proposed directions based on such analyses. From the obtained results it was possible to verify that the impacts caused by the inefficient urban drainage system incur on direct and indirect effects such as flood, erosion and water quality degradation.
Resumo:
This study investigated the effect of slope and antecedent soil moisture on the water depth stored and percolated on extensive green roofs built in pilot scale. For this purpose, slopes of 10, 20 and 30% were investigated. Moisture was measured before and after each test in order to determine the differential moisture (∆U). The experimental runoff and percolated flow were analyzed by varying moisture and slope. Apparent color and turbidity were measured on runoff and percolated flow for each one of the modules. The results yielded that for the slopes of 10% the smaller values of runoff was obtained (average of 1,01% ± 0,7%). For the others slopes (20% and 30%), the runoffs were around 35% ± 15%. The sum of runoff and percolated water results in 77% (average) for slope of 10% and 80% for 20% and 30%. The slope and moisture have explained 87% of data for retained water and 81% for runoff. For percolated flow the inverse trend was observed. The retained water was 11,6±1,4mm for the module with 10% of slope, around 10,0±1,2 mm for the module with 20% of slope, and about 9,5±1,1 mm for the module with 30%. The results pointed out that both slope and antecedent moisture are crucial for runoff reduction and for material transportation.
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
The purpose of a water treatment plant (WTP) is to provide quality water to the population in the municipality where it is operate, being directly linked to the health of the community. The efficiency of a water treatment is directly related to the quality and reliability of the methods used. The analytical results of any laboratory test or calibration is a critical process for any company today. A tool used to assist in a quality management system process is ISO/IEC 17025:2005. Given the above, the objective of this study was to evaluate the performance of an ETA located in Lençóis Paulista-SP, using the analytical results obtained by physical, chemical and microbiological determinations in the period 1-30 October 2015. Such determinations are grounded in compliance with current Ordinance 2914 the Ministry of Health and the Quality Management System, which is required for all laboratories carrying out laboratory tests for control and surveillance of water quality for human consumption