114 resultados para Power quality Disorders
Resumo:
Energy efficiency is an increasingly important issue due to the current scenario where increasing demand is growing faster than the energy supplied. It is important, therefore, analyze and minimize electrical system losses. This study conducts a comparison of a system formed by a photovoltaic generator feeding an LED lamp directly without steps DC-AC -DC conversion, and a system using these conversion steps for the same lamp power. Losses in conversion steps are quantified and the degradation of power quality occurred due to conversion is evaluated
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.
Resumo:
The need for renewable energy sources, facing the consequences of Climate Change, results in growing investment for solar collectors’ use. Research in this field has accompanied this expansion and evacuated tube solar collector stands as an important study focus. Thus, several works have been published for representing the stratification of the fluid inside the tubes and the reservoir, as well as analytical modeling for the heat flow problem. Based on recent publications, this paper proposes the study of solar water heating with evacuated tubes, their operation characteristics and operating parameters. To develop this work, a computational tool will be used - in this case, the application of computational fluid dynamics (CFD) software. In possession of the implemented model, a numerical simulation will be performed to evaluate the behavior of the fluid within this solar collector and possible improvements to be applied in the model.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents a technique to add flexibility in the control of power electronic converters. The power converter can function as an active power filter, as a local power source interface or perform both functions i. e. mitigate current disturbances and inject power into the grid simultaneously, configuring it as a multifunctional device. The main goal is to extract the full capability of the grid connected power electronic converter to achieve maximum benefits. To achieve this goal, the orthogonal current decomposition of the Conservative Power Theory is used. Each orthogonal current component is weighted by means of different compensation factors (k_i), which are set instantaneously and independently, in any percentage by means of the load performance factors (λ_i), providing an online flexibility in relation to compensation objectives. Finally, to validate the effectiveness and performance the proposed approach, simulations and experimental results are presented.
Resumo:
Pós-graduação em Engenharia Elétrica - FEB
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
In this paper, we will present an overview of the smart grid defining the three main systems that compose it: smart infrastructure system, smart management system and smart protection system. We will conceptualize a functionality of smart management system, the conservative voltage reduction, citing its benefits and its history of application. And, finally, we'll cover a test in which we reduce the nominal voltages on incandescent bulbs, CFL and LED, in the context of residential lighting, and on LED and HPS, in the context of public lighting. The test aims to check whether the voltage reduction adversely affects sources of lighting by measuring the temperature manually with a thermal imaging camera FLIR and illuminance with a LUX meter. The set of power factor, total harmonic distortion, and input power values will be collected automatically through the power quality Analyzer Fluke 345 with a probe Fluke Hall Effect Current. For residential lighting, it was found that both CFL and LED had good performance with the smallest variations in illuminance. Between both, the LED source had the lowest harmonics and the lowest power consumption, on the other hand incandescent bulbs had a bad performance as expected. Public light sources also had a good performance and obtained power factors within the standards, as opposed to the CFL and LED residential sources. The data collected clearly shows the feasibility for nominal voltage reductions. Even with small reductions, there are possibilities of savings which can be passed on to the utilities and consumers
Resumo:
Objective: To evaluate the health-related quality of life in children with functional defecation disorders. Methods: One hundred children seen consecutively were enrolled and subdivided into three subsets according to the Roma II classification criteria: functional constipation (n = 57), functional fecal retention (n = 29) and nonretentive functional soiling (n = 14). The generic instrument Child Health Questionnaire - Parent Form 50 (CHQ-PF50®), was used to measure quality of life and to assess the impact of these disorders from the point of view of parents. The instrument measures physical and psychosocial wellbeing in 15 health domains, each of which is graded on a scale from 0 to 100, with higher values indicating better health and greater wellbeing. Ten of these are then used to obtain two aggregated and summary scores: the physical and psychosocial scores. Results: No statistically significant differences were detected between subsets in terms of demographic or anthropometric characteristics. In 14 domains, children with defecation disorders scored lower than healthy children. When subsets were compared, statistically significant differences were detected between children with nonretentive functional soiling (lower scores) and those with functional constipation. Physical and psychosocial scores for the entire sample were lower than those for the group of healthy children used as controls. Conclusions: The CHQ-PF50® was considered adequate for demonstrating compromised quality of life in children with functional defecation disorders, as has been reported for other diseases, being a useful tool for making treatment decisions and for patient follow-up. Copyright © 2006 by Sociedade Brasileira de Pediatria.
Resumo:
Tendinous lesions are very common in athlete horses. The process of tendon healing is slow and the quality of the new tissue is often inferior to the original, leading in many cases to recurrence of the lesion. One of the main reasons for the limited healing capacity of tendons is its poor vascularization. At present, cell therapy is used in equine practice for the treatment of several disorders including tendinitis, desmitis and joint disease. However, there is little information regarding the mechanisms of action of these cells during tissue repair. It is known that Mesenchymal Stem Cells (MSCs) release several growth factors at the site of implantation, some of which promote angiogenesis. Comparison of blood flow using power Doppler ultrasonography was performed after the induction superficial digital flexor tendon tendinitis and implantation of adipose tissue-derived MSCs in order to analyze the effect of cell therapy on tendon neovascularization. For quantification of blood vessel histopathological examinations were conducted. Increased blood flow and number of vessels was observed in treated tendons up to 30 days after cell implantation, suggesting promotion of angiogenesis by the cell therapy.
Resumo:
The literature widely recognizes that shift workers have more health complaints than the general population. The objective of this study was to describe the prevalence of sleep complaints and verify the polysomnographic (PSG) variables of shift workers in two Brazilian nuclear power plants. We carried out a subjective evaluation with a sleep questionnaire. Based on these results, the interviewees that reported sleep-related complaints were referred for polysomnographic evaluation. of the 327 volunteers initially evaluated by the sleep questionnaire, 113 (35%) reported sleep complaints; they were significantly older, had higher body mass index (BMI), and worked more years on shifts than those without sleep complaints. of these 113, 90 met criteria for various sleep disorders: 30 (9%) showed obstructive sleep apnea (OSA), 18 (5.5%) showed limb movement, and 42 (13%) evidenced both sleep problems and had a significantly higher proportion of sleep stage 1 and arousals compared with the 23 shift workers that had no indices of sleep problems. The present study found that 90 (27.5%) of the evaluated participants met the PSG criteria of some type of clinical sleep disorder. This high proportion should be investigated for associations with other aspects of work, such as working hours, working schedule, years performing shift work, and access to health services. Due to the strong association between sleep disorders and the incidence of fatigue and sleepiness, the evaluation of the sleep patterns and complaints of shift workers is essential and should be considered to be one of the basic strategies of industry to prevent accidents.