77 resultados para Plastic Relaxation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Our main objectives were to investigate the affinity properties of endothelial and muscular α1D-adrenoceptors and to characterize the cross-talk between endothelial α1D- adrenoceptors and β2-adrenoceptors in rat carotid. Methods Relaxation and contraction concentration-response curves for phenylephrine (α1-adrenergic agonist) were obtained in carotid rings in absence or presence of increasing concentrations of BMY7378 (α 1D-adrenergic antagonist), combined or not with increasing concentration of ICI-118,551 (β2-adrenergic antagonist). Schild analysis was used to estimate the affinity constant from pA2 values of BMY7378. Key Findings BMY7378 produced an unsurmountable antagonism on phenylephrine-induced relaxation but a surmountable antagonism on phenylephrine-induced contraction. BMY7378 potency was higher in inhibiting the relaxation than the contraction induced by phenylephrine because the rightward shifts induced by BMY7378 were greater in the relaxation. The apparent pA 2 value for BMY7378 in phenylephrine-induced relaxation was greater than in contraction. When combined with ICI-118,551, BMY7378 yielded a surmountable antagonism on phenylephrine-induced relaxation and presented a pA2 value similar to that obtained in phenylephrine-induced contraction. Conclusions Endothelial α1D-adrenoceptors, which mediates rat carotid relaxation, present high ligand affinity because of the cross-talk with β2-adrenoceptors, which explains the higher potency of phenylephrine in inducing relaxation than contraction and the atypical unsurmountable antagonism produced by BMY7378 on phenylephrine-induced relaxation. © 2013 Royal Pharmaceutical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO:O manuseio de materiais está ainda presente nos setores industriais e é associado a lesões na coluna lombar e membros superiores. A inserção de alças em caixas industriais é uma forma de reduzir os riscos relacionados à tarefa, porém a posição e a angulação das alças, que são fatores importantes para o conforto e segurança durante o manuseio, são ainda pouco investigadas objetivamente.OBJETIVOS:Comparar o manuseio de uma caixa comercial e de protótipos com alças e avaliar seus efeitos na postura de membros superiores, atividade elétrica muscular e percepção de agradabilidade em diferentes empunhaduras durante manuseio entre diferentes alturas.MÉTODO:Trinta e sete voluntários saudáveis avaliaram as alças dos protótipos que possibilitavam mudança nas posições (superior e inferior) e angulações (0°, 15° e 30º). Os movimentos dos punhos, cotovelos e ombros foram avaliados por meio da eletrogoniometria e inclinometria. A atividade elétrica muscular dos extensores do punho, bíceps braquial e porção superior do trapézio foi avaliada por um eletromiógrafo portátil. Os registros de movimento e atividade elétrica muscular foram sincronizados. Aspectos subjetivos de agradabilidade foram avaliados por meio de uma escala visual analógica.RESULTADOS E CONCLUSÕES:Os protótipos com alças inclinadas em 30° apresentaram as melhores avaliações de agradabilidade, posturas mais neutras de punho, menores níveis de atividade eletromiográfica do trapézio superior e menores ângulos de elevação dos braços. Os diferentes métodos de medida se mostraram complementares para a avaliação dos membros superiores durante as tarefas de manuseio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaks in pipes are a common issue encountered in the water industry. Acoustic methods are generally successful in finding and locating leaks in metallic pipes, however, they are less effective when applied to plastic pipes. This is because leak-noise signals are heavily attenuated due to high damping in the pipe-wall and sound radiation into the soil. As result, high frequency leak noise does not travel long distances. To determine how far leak noise may travel in a pipe at any frequency, the attenuation of the wave responsible for leak noise propagation should be known. In this paper a new method to estimate this is described. The method is then applied to some measurements made on a bespoke pipe-test rig in the UK, and the results are compared with theoretical predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Convergence to a period one fixed point is investigated for both logistic and cubic maps. For the logistic map the relaxation to the fixed point is considered near a transcritical bifurcation while for the cubic map it is near a pitchfork bifurcation. We confirmed that the convergence to the fixed point in both logistic and cubic maps for a region close to the fixed point goes exponentially fast to the fixed point and with a relaxation time described by a power law of exponent -1. At the bifurcation point, the exponent is not universal and depends on the type of the bifurcation as well as on the nonlinearity of the map.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Curcumin possesses wide-ranging anti-inflammatory and anti-cancer properties and its biological activity can be linked to its potent antioxidant capacity. Superparamagnetic maghemite (gamma-Fe2O3), called surface-active maghemite nanoparticles (SAMNs) were surface-modified with curcumin molecules, due to the presence of under-coordinated Fe-III atoms on the nanoparticle surface. The so-obtained curcumin-modified SAMNs (SAMN@curcumin) had a mean size of 13 +/- 4 nm. SAMN@curcumin was characterized by transmission and scanning electron microscopy, UV/Vis, FTIR, and Mossbauer spectroscopy, X-ray powder diffraction, bulk susceptibility (SQUID), and relaxometry measurements (MRI imaging). The high negative contrast proclivity of SAMN@curcumin to act as potential contrast agent in MRI screenings was also tested. Moreover, the redox properties of bound curcumin were probed by electrochemistry. SAMN@curcumin was studied in the presence of different electroactive molecules, namely hydroquinone, NADH and ferrocyanide, to assess its redox behavior. Finally, SAMN@curcumin was electrochemically probed in the presence of hydrogen peroxide, demonstrating the stability and reactivity of bound curcumin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The establishment of laboratory colonies of ticks is often hampered by their lack of adaptation to alternative hosts. The aim of this study was to artificially feed partially engorged Dermacentor (Anocentor) nitens females through plastic tips, and to identify what are the optimal conditions of application of this technique to get as much as possible close to the natural conditions. The technique of artificial feeding through plastic tips allowed the engorgement of D. nitens ticks to a final weight within the normal range for the species. (C) 2014 Published by Elsevier GmbH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A renormalization-group calculation of the temperature-dependent nuclear spin relaxation rate for a magnetic impurity in a metallic host is reported. The calculation follows a simplified procedure, which produces accurate rates in the low-temperature Fermi-liquid regime, although yielding only qualitatively reliable results at higher temperatures. In all cases considered, as the temperature T diminishes, the rates peak before decaying linearly to zero in the Fermi-liquid range. For T → 0, the results agree very well with Shiba's expression relating the low-temperature coefficient of the relaxation rate to the squared zero-temperature susceptibility. In the Kondo limit, the enhanced susceptibility associated with the Kondo resonance produces a very sharp peak in the relaxation rate near the Kondo temperature. © 1991.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the discovery of YBaCuO, experiments have shown that its superconducting properties are strongly affected by the oxygen content. More recently, anelastic relaxation measurements in La2CuO4+δ, showed that the decrease in the oxygen content can be related to two events. One is the decrease in mobility between two adjacent CuO planes, and the other is the increase in the number of tilting patterns of the CuO6 octahedra. In the case of the bismuth-based ceramic, it is known that the oxygen content, within some limits, does not affect its superconducting properties. In order to evaluate the mobility and the effect of the oxygen content on this material we have prepared BSCCO ceramic and tested regarding its internal friction and electrical resistivity as a function of the temperature while the oxygen content was being reduced by a sequence of vacuum annelaing at 620 K. The samples were prepared in the Bi:Sr:Ca:Cu = 2212 and 2223 proportion, using powder obtained by the sol-gel route and conventional solid state reaction. The anelastic relaxation measurements were performed using a torsion pendulum operating with frequency about 15-35 Hz between 77 to 700 K. The diffraction pattern of the as sintered and the vacuum annealed material were also presented. The results have shown complex anelastic relaxation structures that were associated to the jump of interstitial oxygen atoms between two adjacent CuO planes. The vacuum annealing showed to be deleterious to the critical temperature of the superconducting ceramic.