75 resultados para POWER LASER
Resumo:
This study evaluated the effect on micro-tensile bond strength (mu-TBS) of laser irradiation of etched/unetched dentin through an uncured self-etching adhesive. Dentinal surfaces were treated with Clearfil SE Bond Adhesive (CSE) either according to the manufacturer's instructions (CSE) or without applying the primer (CSE/NP). The dentin was irradiated through the uncured adhesive, using an Nd: YAG laser at 0.75 or 1 W power settings. The adhesive was cured, composite crowns were built up, and the teeth were sectioned into beams (0.49 mm(2)) to be stressed under tension. Data were analyzed using one-way ANOVA and Tukey statistics (alpha = 5%). Dentin of the fractured specimens and the interfaces of untested beams were observed under scanning electron microscopy (SEM). The results showed that non-etched irradiated surfaces presented higher mu-TBS than etched and irradiated surfaces (p < 0.05). Laser irradiation alone did not lead to differences in mu-TBS (p > 0.05). SEM showed solidification globules on the surfaces of the specimens. The interfaces were similar on irradiated and non-irradiated surfaces. Laser irradiation of dentin through the uncured adhesive did not lead to higher mu-TBS when compared to the suggested manufacturer's technique. However, this treatment brought benefits when performed on unetched dentin, since bond strengths were higher when compared to etched dentin.
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Odontologia - ICT
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the effects of the use of a high-power gallium-aluminum-arsenide diode laser (GaAlAs; 808 nm, 1 W, 20 s, 20 Hz, 10 J) alone or as adjunctive therapy to scaling and root planing in the treatment of induced periodontitis in rats. Periodontitis was induced by placing a ligature around the mandibular first molar of 60 rats. After 7 days, the ligature was removed and the animals were divided into four groups as follows: C (control), no periodontal treatment; SRP, scaling and root planing (SRP); DL, diode laser (DL) irradiation treatment; and SRP/DL, both SRP and DL irradiation treatment. Five animals from each group were euthanized at 7, 15, and 30 days posttreatment. The effectiveness of the treatments was evaluated in the furcation area using histopathological analysis, histometric analysis of alveolar bone loss (ABL), and immunohistochemical detection of tartrate-resistant acid phosphatase (TRAP), runt-related transcription factor 2 (RUNX2), and osteocalcin (OCN). DL, alone or in combination with adjunctive therapy to SRP in the treatment of experimental periodontitis, resulted in a decreased local inflammatory response. At 7-days posttreatment, the DL and SRP/DL groups had fewer TRAP-positive cells and more RUNX2-positive cells. There was greater OCN immunolabeling in the DL group than in the C and SRP groups at 15 days. There was less ABL in the DL and SRP/DL groups at 15 and 30 days. In conclusion, DL was effective in the treatment of ligature-induced periodontitis in rats, both when used alone and when used as adjunctive therapy to SRP.
Resumo:
The aim of this study was to evaluate the effects of a Gallium Arsenide (GaAs) laser, using a high final energy of 4.8J, during muscle regeneration after cryoinjury. Thirty Wistar rats were divided into three groups: Control (C, n=10); Injured (I, n=10) and Injured and laser treated (Injured/LLLT, n=10). The cryoinjury was induced in the central region of the tibialis anterior muscle (TA). The applications of the laser (904nm, 50mW average power) were initiated 24h after injury, at energy density of 69Jcm(-1) for 48s, for 5days, to two points of the lesion. Twenty-four hours after the final application, the TA muscle was removed and frozen in liquid nitrogen to assess the general muscle morphology and the gene expression of TNF-, TGF-, MyoD, and Myogenin. The Injured/LLLT group presented a higher number of regenerating fibers and fewer degenerating fibers (P<0.05) without changes in the collagen remodeling. In addition, the Injured/LLLT group presented a significant decrease in the expression of TNF- and myogenin compared to the injured group (P<0.05). The results suggest that the GaAs laser, using a high final energy after cryoinjury, promotes muscle recovery without changing the collagen remodeling in the muscle extracellular matrix.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: A morphological and ultra-structural study of copper vapor laser (λ = 510.6 nm) effects on enamel and dentine was performed to show the effects of this radiation. Methods: A total of 15 human molars were cut in half; 15 pieces were separated for irradiation on enamel and 15 for dentine. These two groups were further divided into five experimental groups, including a control group, comprised of three half-sections each, irradiated by a CVL laser with a power of 7 W, a repetition rate of 15,000 pulses/sec and exposed at 500, 600, and 800 msec and 1 sec irradiation times with a 5-sec interval between irradiations. Results: In an ultra-structural SEM exam, we observed that on the enamel surfaces irradiated for 1 sec there was morphological alteration that consisted of catering, flaking, and melting on the surfaces. There was no alteration for the other exposure times. On the dentine teeth irradiated for 1 sec, we observed an evident ultra-structural alteration of melted tissue and loss of morphological characteristics. In the dentine group irradiated by 800 msec, we observed ablation and a partial loss of morphological characteristics. In the dentine groups irradiated by 500 and 600 msec, no alteration was observed. Conclusions: The results showed that irradiation with CVL promoted morphologic changes in the enamel as well as in the dentine and demonstrated a need for future studies in order to establish a safe protocol for further use in the odontological practice.
Resumo:
Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante.
Resumo:
This study evaluated the influence of the surface pretreatment of indirect resin composite (Signum, Admira Lab and Sinfony) on the microtensile bond strength of a resin cement. Sixty samples made of each brand were divided into 6 groups, according to surface treatment: (1) control; (2) controlled-air abrasion with Al2O3; (3) Er:YAG Laser 200 mJ, 10 Hz, for 10s; (4) Er: YAG Laser 300 mJ, 10 Hz, for 10 s; (5) Nd:YAG 80 mJ, S15Hz for 1 min; (6) Nd:YAG 120mJ, 15 Hz for 1 min. After treatments, all the groups received an application of 37% phosphoric acid and adhesive. The pair of blocks of the same brand were cemented to each other with dual resin cement. The blocks were sectioned to obtain resin-resin sticks (1 x1 mm) and analyzed by microtensile bond testing. The bond strength values were statistically different, irrespective of the surface treatment performed, with highest values for Sinfony (43.81 MPa) and lowest values for Signum (32.33 MPA). The groups treated with the Nd:YAG laser showed the lowest bond strength values and power did not interfere in the results, both for Nd:YAG laser and Er:YAG. Controlled-air abrasion with Al203 is an efficient surface treatment method and the use of the Nd:YAG and Er:YAG lasers reduced bond strength, irrespective of the intensity of energy used.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.
Resumo:
Introduction: As a new alternative in the complementary treatment lasers teem different systems were employed in the decontamination of dental surfaces implants however, some systems have caused significant changes in its surface. Purpose: Analyze by Scanning Electron Microscopy (SEM) the effects of laser irradiation of Er,Cr: YSGG on different surfaces of titanium. Material and method: Study of 20 titanium discs, and 10 Machined Surface (MS) and 10 surfaces treated with acid (AC). The 10 discs with the same treatment were divided into two groups with five units each, the irradiation was performed in powers of 1 W and 2 W. Result: Showed that the irradiation with 1 W of power resulted in no significant morphological changes in the MS-irradiated compared to non-irradiated surfaces. In MS surfaces, minor changes were observed in the increase of 1000× when compared to non-irradiated surface. With 2 W of power, there were no significant morphological changes in the MS, compared to non-irradiated areas. In AC some changes were observed in the increase of X 1000, showing areas of wear suggestive of treatment and some areas with melting point. Conclusion: Considering the results and the parameters used in this study it was concluded that the Er, Cr: YSGG irradiation can be used for the machined surfaces of implants, but in acid-treated surfaces irradiation parameters should be more controlled.