151 resultados para Marginal lakes
Resumo:
The purpose of this in vitro study was to investigate the cervical marginal leakage in class II restorations with chemically cured resin (P10) and light-cured resin (P30) in two types of cavities: conventional and adhesive. The effect of acid-etching in this area was also observed. Dentine adhesive Scotchbond was used in all experimental groups. Leakage was evidenced by Rodamina B dye penetration after thermocycling procedure between 10 degrees C and 50 degrees C temperature and analysed by using Zeiss Stereoscopic Magnifying Glass (10 X). According to the results obtained marginal leakage occurred in all experimental groups, with lower percentage for adhesives cavities when enamel acid-etching and light-cured resin P30 was used.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Standardization of measurements for marginal fit of castings is critical. This study describes the fabrication of a device that allowed fixation of specimens on a Toolmakers microscope with identical conditions according to tri-dimensional positioning of specimens, measuring location, and seating force. The device also allows mapping of the marginal discrepancies on the entire marginal perimeter of the tooth preparation.
Resumo:
STATEMENT OF PROBLEM: Despite careful procedures, master stone dies may be damaged during laboratory procedures. The dentist routinely adjusts castings because the marginal fit of casting is not as accurate as on the dies. PURPOSE: This study evaluated the technique of internal adjustment of castings with use of duplicated stone dies and a disclosing agent to improve marginal fit discrepancy. MATERIAL AND METHODS: Thirty-two nickel-chromium copings were fabricated and simulated standard clinical and laboratory procedures with 2 variables: tooth preparation convergence angles of 6 and 18 degrees, with or without internal relief. Master stone dies and their duplicates were selected for coping construction and internal adjustment, respectively. A specimen positioning device was coupled with a Toolmakers microscope to allow reproducibility of measurements. Each coping was evaluated at 8 locations of its marginal perimeter, before and after internal adjustment. RESULTS: Marginal fit discrepancy of copings were significantly reduced with an internal adjustment technique (mean > 52%) for all experimental groups. Tooth preparations with greater convergence and internally relieved castings recorded a better marginal fit. CONCLUSION: The casting internal adjustment technique with use of duplicated stone dies and a disclosing agent substantially reduced marginal fit discrepancy.
Resumo:
Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class II standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z100 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5°C and 55°C for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: The results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.
Resumo:
The abundance of zooplankton in two lakes of Southwest Amazonia was studied for 10 months in different regions and at different periods of the day. The lakes were Lago Amapá, located at 10°02′36″S, 67°50′24″W, and Lago Pirapora, at 9°27′21″S, 67°31′39″. Both lakes are characterized as oxbow lakes. The aim of this study was to compare the pelagic and littoral regions, as well as to determine differences in the distribution of zooplankton in the water column in the morning and at night. Collections were made by filtering water through a 55μm zooplankton net into a 5L Van Dorn bottle, collecting 4L from the top and 5L from the middle and bottom layers, totaling 14L of water for each sampling location. In addition, physical and chemical parameters were measured, including transparency, temperature, pH, dissolved oxygen, electrical conductivity and turbidity. Anova (analysis of variance) and Tukey's test were used. There was no statistically significant difference between the regions studied, nor between the two time periods examined. The results of the Pearson correlation (p<0.05) demonstrated that the physical and chemical characteristics of the water correlated with the cladocerans Moina spp. (represented by M. minuta and M. reticulata) and Ceriodaphnia cornuta, and that Daphnia gessneri was associated with Chaoboridae.
Resumo:
The present study shows the distribution of alien fish species in tropical lakes in the middle Doce river basin, southeastern Brazil, obtained from a rapid assessment program. The causes for their introductions were sport-fishing improvement in some specific lakes and aquaculture in the studied basin. Presently, these species have a wide distribution occurring in 41 of the 54 lakes studied, representing an actual threat to regional native fish community. The natural connection among lakes and streams during the rainy season and the dispersal mediated by local people are the main invasion agents for alien fishes. The success of these invaders is probably due to absence of pre-existing effective competitors or top-predators in the invaded communities. We consider that the eradication of alien fishes by means of the available management tools may be very difficult due to the large number of lakes invaded and to the wide spectrum of lake conditions and resources exploited by these alien species. We recommend the use of environmental education as a tool to stop the human-mediated dispersion of aliens and to improve conservation of native fish community in lakes where these alien species are not present yet. © 2004 Instituto de Ciências Biológicas - UFMG.
Resumo:
Coqueiral lake is a marginal lake located at the southeast São Paulo State, in the mouth zone of the Paranapanema river into Jurumirim Reservoir and it has high connectivity with the Paranapaneina river. This work aimed to verify the benthic biodiversity in areas of the lake bottom. 18 sampling sites in the lake were selected, including shallow and deep areas. The samples were taken every three months during one year. Physical and chemical water variables (level, transparency, dissolved oxygen, pH, and electric conductivity) were analyzed. Sediment samples were picked up in triplicate for fauna and abiotic factors analysis (granulometric composition and sediment organic content), using Petersen dredge. The material was sorted out and analyzed under stereoscopic microscope. Counting and identification of the organisms were accomplished and diversity, relative abundance, taxonomic richness and dominance index were calculated. The analysis revealed a fauna with low species diversity and, with Chironomidae and Ephemeroptera dominance. Ephemeroptera, Campsurus, dominated in the hottest period and with low lake depth. Organisms' distribution had as main factors depth, transparency, pH, and water temperature. In the comparison between shallow and deep areas, a small density of organism in the deep regions was observed.
Resumo:
OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.
Resumo:
Objectives: This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. Methods: Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application; control group - 10 premachined UCLA abutments, cast with noble metal alloy and submitted to ceramic application. Vertical misfit measurements were performed under light microscopy. In the test group, measurements were performed before and after the use of cast rectifiers, and after ceramic application. In the control group, measurements were performed before and after casting, and after ceramic application. Data were submitted to statistical analysis by ANOVA and Tukey's test (α= 5%). Results: The use of cast rectifiers significantly reduced the marginal misfit of cast UCLA abutments (from 25.68μm to 14.83μm; p<0.05). After ceramic application, the rectified cylinders presented misfit values (16.18μm) similar to those of premachined components (14.3 μm). Casting of the premachined UCLA abutments altered the marginal misfit of these components (from 9.63 μm to 14.6 μm; p<0.05). There were no significant changes after porcelain baking, in both groups. Conclusion: The use of cast rectifiers reduced the vertical misfit of cast UCLA abutments. Even with carefully performed laboratory steps, changes at the implant interface of premachined UCLA abutments occurred. Ceramic application did not alter the marginal misfit values of UCLA abutments.
Resumo:
This study carried out an in vitro evaluation and comparison of the occurrence of marginal leakage in bonded restorations using mechanical or chemical-mechanical (Carisolv) removal of carious tissue. For that purpose, 40 extracted decayed human molars were divided into 4 groups: GI (burs + Prime & Bond NT + TPH), GII (Carisolv + Prime & Bond NT + TPH), GIII (burs + SBMP + Z100) and GIV (Carisolv + SBMP + Z100). After accomplishment of the restorations and thermal cycling, the teeth were exposed to dye, sectioned and qualitatively evaluated. The results demonstrated that the system of removal of carious tissue did not influence the results of microleakage at any of the cavity margins. At dentinal margins, use of the Prime & Bond NT + TPH restorative system allowed the occurrence of less microleakage than the SBMP + Z100 system.
Resumo:
The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5%). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2% rhodamine B and the MTA-Pro Root cement presented different OD values in all 2% rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.
Resumo:
Vascular plants were investigated in oxbow lakes of Turvo River, Upper Paraná River basin, between Icém and Nova Granada municipalities, state of São Paulo, Brazil. In this region, six lagoons were sampled: Ganzella, Mustafá, Braço Morto, 45, Federal, and Parente. The survey showed a total of 54 species, 36 genera and 22 families. The species richest families were Poaceae, Cyperaceae, and Polygonaceae. Eichhornia crassipes (Pontederiaceae) was the single species encountered in all the six lakes. © 2010 Check List and Authors.
Resumo:
Osteopetrosis (OP) is a rare hereditary disorder characterized by a dysfunction of the osteoclasts that impairs bone resorption, which together with the normal osteoblastic activity forms intense bone sclerosis with reduction of marrow. A common complication that arises, most frequently, as a result of tooth extraction is mandibular osteomyelitis. There is no consensus on the literature about the treatment of this infection in an osteopetrotic patient, therefore, the purpose of this paper is to report a case of marginal resection for treatment of mandibular osteomyelitis in an osteopetrotic patient and discuss relevant features of this procedure. © 2010 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
Aim: To evaluate the influence of the width of the buccal bony wall on hard and soft tissue dimensions following implant installation. Material and methods: Mandibular premolars and first molars of six Labrador dogs were extracted bilaterally. After 3 months of healing, two recipient sites, one on each side of the mandible, were prepared in such a way as to obtain a buccal bony ridge width of about 2 mm in the right (control) and 1 mm in the left sides (test), respectively. Implants were installed with the coronal margin flush with the buccal alveolar bony crest. Abutments were placed and the flaps were sutured to allow a non-submerged healing. After 3 months, the animals were euthanized and ground sections obtained. Results: All implants were completely osseointegrated. In respect to the coronal rough margin of the implant, the most coronal bone-to-implant contact was apically located 1.04 ± 0.91 and 0.94 ± 0.87 mm at the test and control sites, respectively, whereas the top of the bony crest was located 0.30 ± 0.40 mm at the test and 0.57 ± 0.49 mm at the control sites. No statistically significant differences were found. A larger horizontal bone resorption, however, evaluated 1 mm apically to the rough margin, was found at the control (1.1 ± 0.7 mm) compared to the test (0.3 ± 0.3 mm) sites, the difference being statistically significant. A thin peri-implant mucosa (2.4-2.6 mm) was found at implant installation while, after 3 months of healing, a biological width of 3.90-4.40 mm was observed with no statistically significant differences between control and test sites. Conclusions: A width of the buccal bony wall of 1or 2 mm at implant sites yielded similar results after 3 months of healing in relation of hard tissue and soft tissues dimensions after implant installation. © 2012 John Wiley & Sons A/S.