75 resultados para MOLDING


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential of clear Ga2S3-GeS2-CsCl based sulfide glasses transparent up to 11.5 μm to be used as new optical material for multispectral applications has been investigated. The addition of large amount of chlorine ions – above 40 mol.% of CsCl – into the chalcogenide vitreous network in order to produce colorless glasses results in a drastic increase of their water contamination. We report for the first time, to the best of our knowledge, the purification of cesium chloride CsCl by dynamic distillations under vacuum in order to reduce water and hydroxyl group contamination before complete melting of the glass. Besides, sulfur purification by dynamic and static distillations was also performed in the implemented method. The obtained glasses were then characterized by UV-visible and infrared (FTIR) spectroscopies, by electron probe microanalysis (EPMA), thermal analysis (DSC), and their refractive indices in the visible and near infrared ranges were also measured. A large improvement of the glass transmission spectrum has been achieved with an estimated reduction of about 45 times of the OH and H2O content and 60 times of the SH content. The glass thermal molding ability and chemical durability with and without protective coating have been tested to probe their potential for fabrication of complex optics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims at describeconstruction and installation sequences of a new design of appliance that allows continuously protraction of the mandible, using the telescopic mechanism of the Herbst appliance. This appliance has the advantage to be easily assembled by the orthodontist, without the necessity of molding and the assistance of a specialized laboratory, as well as the constant permanence in the mouth of the patient for being fixed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to present a systematized review of different methods used to evaluate the masticatory efficiency in conventional complete denture wearers. A survey was conducted in the databases PubMed, Scopus, and Cochrane, seeking scientific articles according to the previously selected terms: "Masticatory performance", "Masticatory efficiency" and "Chewing ability complete denture". Moreover, complementary studies have been carried out with library manual search/databases, which included studies related to different ways to assess masticatory efficiency, specifically as it related to conventional complete denture wearers. Forty three papers were selected to be used in the present review. Despite the wide variety of methodologies in the literature, the sieves method is currently considered the gold standard method to evaluation of conventional complete denture wearers masticatory efficiency, since it is the simplest, does not depend on specific devices (beyond the set of sieves), allows for a rational assessment, and it has been widely reproduced in various types of oral rehabilitation. More, the almond, as natural test food, and the optocal (made from the molding material Optosil), as artificial test food, are the most constantly employed test foods to evaluate masticatory efficiency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Advanced Layering composite resins can be facilitated by a technique called "Lingual Matrix", where a guide is made of elastomer by molding a previously waxed tooth or sculped in an intraoral test drive restoration. This technique has many advantages to sophisticated layering, facilitation stratification, anatomic construcrion and the stages of finishing and polishing. However, in some clinical situations, the unfolding of the steps to obtains this matrix can be time consuming or even infeasible. To facilitate the achievement of this apparatus, a technique was idealized allowing significant reducrion in clinical time. This matrix, called the "BRB Matrix" is widly discussed in a didactic and clinical manner in this article, presenting its advantages in clinical cases where it is imperative to use a guide for conduction a controlled layering. The simplicity of this approach, as well as reduced clinical time and finacial costs turn it feasible in an everyday clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the internal fit, marginal adaptation, and bond strengths of inlays made of computer-aided design/computer-aided manufacturing feldspathic ceramic and polymer-infiltrated ceramic. Twenty molars were randomly selected and prepared to receive inlays that were milled from both materials. Before cementation, internal fit was achieved using the replica technique by molding the internal surface with addition silicone and measuring the cement thicknesses of the pulpal and axial walls. Marginal adaptation was measured on the occlusal and proximal margins of the replica. The inlays were then cemented using resin cement (Panavia F2.0) and subjected to two million thermomechanical cycles in water (200 N load and 3.8-Hz frequency). The restored teeth were then cut into beams, using a lathe, for microtensile testing. The contact angles, marginal integrity, and surface patterns after etching were also observed. Statistical analysis was performed using two-way repeated measures analysis of variance (p<0.05), the Tukey test for internal fit and marginal adaptation, and the Student t-test for bond strength. The failure types (adhesive or cohesive) were classified on each fractured beam. The results showed that the misfit of the pulpal walls (p=0.0002) and the marginal adaptation (p=0.0001) of the feldspathic ceramic were significantly higher when compared to those of the polymer-infiltrated ceramic, while the bond strength values of the former were higher when compared to those of the latter. The contact angle of the polymer-infiltrated ceramic was also higher. In the present study, the hybrid ceramic presented improved internal and marginal adaptation, but the bond strengths were higher for the feldspathic ceramic.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the clinical effectiveness of two bleaching agents without changing the whitening gel during the clinic session 1X45minutos. 10 patients were selected according to the criteria of inclusion and exclusion and upper arch of the patients were divided into two quadrants (n: 10), G1: gel clareador Clàriant Office (hidrogênio35 Angellus) peroxide% (PH) in superior right side (LD) and the gel WhitenessHp Blue (FGM) PH 35% on the superior left side (LE. 2 clinical sessions were accomplished, 45 minutes each, with an interval of one week between sessions. At first the bleaching treatment patients received prophylaxis, molding to guide measurement of color with condensation silicon and the color evaluation through the apparel spectrophotometer VITA Easyshade (Vita Zhanfabrik, Alemanhã). 14 days after the end of the bleaching treatment was performed the measurement final color of the teeth. The patients reported sensitivity in scale 0-4. The result showed that through T Test comparing quadrants presented no statistical differences (p>0,05) in relation to coloration and dental sensibility. It can be concluded that the materials evaluated are effective for bleaching vital teeth with low tooth sensibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The product development field daily works in the chase of new materials and technologies that fulfills the requirements of the consumer market. So, projects are developed in order to theoretically predict what will actually happen. The production of household appliance is not different. To provide a pleasant bath to the costumer, the manufacture of a bathtub counts on many components. With this in mind, this work goal is to study the possibility of production by plastic injection of the assembly water source/overflow pipe used in bathtubs and compare its production cost with the cost of the assembly acquired from third parties. The injection process is widely used on the world stage because of its numerous advantages, however, due to the high cost of the molds, it is important to estimate the time required for the return of the initial investment. To do this, a model was designed to examine its dimensions and then initiate the study of the possibility to inject the components with the available injection machine and the production cycle. With the results, it was found that there was a reduction in the cost of the finished assembly, but a very long time to return the initial investment due to the current financial scenery of the country