117 resultados para Light curing unit
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To evaluate the bone regeneration of cervical defects produced around titanium implants filled with blood clot and filled with centrifuged bone marrow (CBM) by means of histomorphometric analysis.Materials and Methods: Twelve rabbits received 2 titanium implants in each right tibia, with the upper cortical prepared with a 5-mm drill and the lower cortex with a 3-mm-diameter drill. Euthanasia was performed to allow analysis at 7, 21, and 60 days after operation. The samples were embedded in light curing resin, cut and stained with alizarin red and Stevenel blue for a histomorphometric analysis of the bone-to-implant contact (BIC) and the bone area around implant (BA). The values obtained were statistically analyzed using the nonparametric Kruskal-Wallis test (P = 0.05).Results: At 60 days postoperation, the groups had their cervical defects completely filled by neo-formed bone tissue. There was no statistically significant difference between the groups regarding BIC and BA during the analyzed periods.Conclusion: There was no difference in the bone repair of periimplant cervical defects with or without the use of CBM. (Implant Dent 2012;21:481-485)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.
Resumo:
Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The effect of application methods and dentin hydration on the bond strength of three self-etching adhesives (SEA) were evaluated; 195 extracted bovine incisors were used. The buccal surface was ground in order to expose the dentin, which remained 2-mm minimum thickness, measured by a thickness meter through an opening on the lingual surface. Adper Single Bond 2 (TM) was used for the control group. The SEA were applied following two modes of application: passive or active and two hydration states of the dentin surface-dry and wet. After light-curing, composite buildups were made using Grandio (TM) composite. The specimens were sectioned and tested with a microtensile bond strength test. The application method and the hydration state resulted in statistical differences (p = 0.000) making the values of active application for mu TBS to dentin higher than passive application. The wet surfaces showed higher mu TBS to dentin ratios than dry surfaces. There were no statistical differences in mu TBS among the SEA tested but there were differences regarding to control group.
Resumo:
Objective: To study the influence of color opacity and light-curing systems (halogen light vs blue LED) on the microhardness of a composite resin. Methods: Esthet-X composite resin (Dentsply), shades A2 and A2-O, was inserted in a stainless steel matrix (5 mm diameter and 2 mm deep) and was light cured for 40 seconds with a halogen light source (XL 3000; 3M/ESPE) or a blue LED (Optilight LD II; Gnatus). Eight groups of 15 specimens each were formed, and were further divided according to the light-curing systems, the exposed area (base and surface), and the opacity of the composite resin, producing 120 specimens. The specimens were next stored in distilled water for 24 hours, embedded in a chemically activated acrylic resin, then subjected to finishing and polishing with sandpaper and felt discs. Microhardness was measured with a Vickers Digital Microhardness meter, with a 50 g load for 30 seconds. The obtained microhardness means were analyzed by ANOVA and Tukey's multiple-comparison test at 5% significance level. Results: The surface microhardness was always greater than the base microhardness, regardless of the light-curing source. The halogen light lamp produced significantly higher composite resin microhardness means than the blue LED (57.61 vs. 42.53 HV) (p<0.05). Statistically significant differences (p<0.05) were obtained between the microhardness means for the different composite opacities; lowest microhardness in depth was produced by the A2-O shade. Conclusion: Composite resin opacity as well as the light-curing system influenced the microhardness of the material.
Resumo:
This study evaluated the influence of surface treatment on the shear bond strength of a composite resin (CR), previously submitted to the application of a temporary cement (TC), to an adhesive luting cement. Eight-four CR cylinders (5 mm diameter and 3 mm high) were fabricated and embedded in acrylic resin. The sets were divided into 6 groups (G1 to G6) (n=12). Groups 2 to 6 received a coat of TC. After 24 h, TC was removed and the CR surfaces received the following treatments: G2: ethanol; G3: rotary brush and pumice; G4: air-abrasion; G5: air-abrasion and adhesive system; G6: air-abrasion, acid etching and adhesive system. G1 (control) did not receive TC or any surface treatment. The sets were adapted to a matrix and received an increment of an adhesive luting cement. The specimens were subjected to the shear bond strength test. ANOVA and Tukey's tests showed that G3 (8.53 MPa) and G4 (8.63 MPa) differed significantly (p=0.001) from G1 (13.34 MPa). The highest mean shear bond strength values were found in G5 (14.78 MPa) and G6 (15.86 MPa). Air-abrasion of CR surface associated with an adhesive system provided an effective bond of the CR to the adhesive luting cement, regardless the pre-treatment with the phosphoric acid.
Resumo:
Aims and objectives: The behavior of polymer-matrix composite is dependent on the degree of conversion. The aim of this study was to evaluate the degree of conversion of two resin cements following storage at 37°C immediately, 24 and 48 hours, and 7 days after light-curing by FTIR analysis. Materials and methods: The specimens were made in a metallic mold and cured with blue LED with power density of 500 mW/cm2 for 30 seconds. The specimens were pulverized, pressed with KBr and analyzed with FTIR following storage times. Statistical analysis used: ANOVA (two-way) and Tukey's post hoc. Results: To the polymer-matrix composites between 24 and 48 hours does not show a significant increase (p > 0.05), however, the highest values were found after 7 days. Conclusion: The polymer-matrix composites used in this study showed similarity on the degree of conversion and increased of according to the time of storage.