348 resultados para Immediate implant
Resumo:
Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.
Resumo:
The transmission of influenza in health care settings is a major threat to patients, especially those with severe diseases. The attitude of health care workers (HCWs) may influence the transmission of countless infections. The current study aimed to quantify knowledge and identify attitudes of HCWs involved in intensive care units (ICUs) regarding the risk of nosocomial influenza transmission. A questionnaire was applied through interviews to HCWs who worked in one of the five ICUs from a teaching hospital. Questions about influenza were deliberately dispersed among others that assessed several infectious agents. Forty-two HCWs were interviewed: nine physicians, ten nurses and 23 nursing technicians or auxiliaries. Among the 42 HCWs, 98% were aware of the potential transmission of influenza virus in the ICUs, but only 31% would indicate droplet precautions for patients with suspected infection. Moreover, only 31% of them had been vaccinated against influenza in the last campaign (2008). Nursing technicians or auxiliaries were more likely to have been vaccinated, both by univariate and multivariable analysis. When asked about absenteeism, only 10% of the study subjects stated that they would not go to work if they had an influenza-like illness. Those findings suggest that, in non-pandemic periods, influenza control in hospitals requires strategies that combine continuous education with changes in organizational culture.
Resumo:
OBJETIVO: Avaliar o efeito do laser de baixa intensidade sobre a contração da pseudocápsula que ocorre ao redor de implantes de silicone. MÉTODOS: 60 ratos machos divididos em dois grupos receberam implante de silicone. Grupo I: implante no subcutâneo da região dorsal, sem tratamento após a cirurgia; Grupo II: animais receberam sete sessões de irradiação com laser de baixa intensidade após o implante. Trinta, 60 e 180 dias após a cirurgia, foi feita a tonometria dos implantes, em seguida, os animais foram sacrificados, removendo-se o material de estudo que foi preparado para exame histológico, avaliando-se morfometricamente a espessura da pseudocápsula e a reação inflamatória. A análise estatistica pela técnica da Análise de Variância e Teste de Tukey (P<0.0 5). RESULTADOS: Pressões significativamente menores foram encontradas nos animais do grupo Grupo II. O estudo histológico não mostrou diferença significativa entre os grupos, destacando-se apenas maior quantidade de vasos intumescidos no Grupo II. A espessura da pseudocápsula foi menor no Grupo II. CONCLUSÃO: O laser de baixa intensidade altera o processo de reparação tecidual ao redor dos implantes, sugerindo que o mesmo possa ser útil para a modelação das contraturas que se estabelecem ao redor dos implantes de silicone.
Resumo:
Superficial digital flexor tendonitis is an important cause of lameness in horses and its incidence ranges from 13% to 30%, depending on the horse's activity. This injury can occur in yearlings and compromise its carriers by reinjury or even impossibility to return to athletic life. In spite of the long period required for tendon repair, the scar tissue presents lack of elasticity and stiffness. As current treatment strategies produce only marginal results, there has been great interest in research of therapies that influence the quality or the speed of tendon repair. Stem cell therapy has shown promising results in degenerative diseases and cases of deficient healing processes. This study aims to evaluate the influence of autologous mesenchymal bone marrow stem cells in tendon healing, comparing treated and non-treated tendons. Superficial digital flexor tendonitis lesions were induced by collagenase infiltration in both forelimbs of 6 horses, followed by autologous implant in one of the forelimbs of each animal. The horses were evaluated using clinical, ultrasonographic, histopathologic, and immunohistochemical parameters. Tendon biopsies were performed at Day 48. Results found in the treatment group, such as high inflammatory cells infiltration, extracellular matrix synthesis, reduced amount of necrosis areas, small increase in cellular proliferation (KI-67/MIB-1), and low immunoreactivity to transforming growth factor P I, suggested the acceleration of tendon repair in this group. Further studies should be conducted in order to verify the influence of this treatment on later phases of tendon repair. Overall, after analysis of the results, we can conclude that cellular therapy with the mononuclear fraction of bone marrow has accelerated tendon repair at 48 days after treatment.
Resumo:
Endodontic treatment is an important step of tooth replantation protocols, but the ideal moment for definitive obturation of replanted teeth has not yet been established. In this study, a histomorphometric analysis was undertaken to evaluate the repair process on immediate replantation of monkeys teeth after calcium hydroxide (CH) therapy for 1 and 6 months followed by root canal filling with a CH-based sealer (Sealapex (R)). The maxillary and mandibular lateral incisors of five female Cebus apella monkeys were extracted, kept in sterile saline for 15 min, replanted and splinted with stainless steel orthodontic wire and composite resin for 10 days. In Group I (control), definitive root canal filling was performed before tooth extraction. In Groups II and III, CH therapy started after removal of splint, and definitive root canal filling was performed 1 and 6 months later, respectively. The animals were euthanized 9 months after replantation, and specimens were processed for histomorphometric analysis. In all groups, epithelial attachment occurred at the cementoenamel junction or very close to this region; the areas of resorption on root surface had small extension and depth and were repaired by newly formed cementum; and the periodontal ligament was organized. Statistical analysis of the scores obtained for the histomorphometric parameters did not show any statistically significant difference (P = 0.1221) among the groups. The results suggests that when endodontic treatment is initiated 10 days after immediate replantation and an antibiotic regimen is associated, definitive root canal filling can be performed after a short-term CH therapy.
Resumo:
The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.
Resumo:
Purpose: The aim of this study was to assess the influence of cusp inclination on stress distribution in implant-supported prostheses by 3D finite element method.Materials and Methods: Three-dimensional models were created to simulate a mandibular bone section with an implant (3.75 mm diameter x 10 mm length) and crown by means of a 3D scanner and 3D CAD software. A screw-retained single crown was simulated using three cusp inclinations (10 degrees, 20 degrees, 30 degrees). The 3D models (model 10d, model 20d, and model 30d) were transferred to the finite element program NeiNastran 9.0 to generate a mesh and perform the stress analysis. An oblique load of 200 N was applied on the internal vestibular face of the metal ceramic crown.Results: The results were visualized by means of von Mises stress maps. Maximum stress concentration was located at the point of application. The implant showed higher stress values in model 30d (160.68 MPa). Cortical bone showed higher stress values in model 10d (28.23 MPa).Conclusion: Stresses on the implant and implant/abutment interface increased with increasing cusp inclination, and stresses on the cortical bone decreased with increasing cusp inclination.
Resumo:
This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality.
Resumo:
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to evaluate implants installed with compromised primary stability associated or not with polylactide and polyglycolide copolymer (PLA/PGA). Two 0.4-mm overdrilled defects (3 mm in diameter and 6 mm long) were produced in the right tibia of 25 rabbits. Half of the defects were left untreated, and the other half was filled with PLA/PGA. Implants of 2.6 mm in diameter and 6 mm long were placed into all defects. Animals were killed at 5, 15, 40, and 60 postoperative days, and biomechanical analysis (torque-reverse), histomorphometry, and immunohistochemistry (osteoprotegerin, receptor activator of NFJB ligand [RANKL], osteocalcin, and collagen-1 [ COL- I] staining) were performed. All the implants achieved osseointegration. There were no statistically significant differences in the torque-reverse and in linear contact extension between bone tissue and implant surface and no statistically significant difference in osteoprotegerin, RANKL, osteocalcin, and collagen-1 expression between the studied groups in all studied periods (P > 0.05). We can conclude that osseointegration can occur in compromised primary implant stability situations, and the addition of PLA/PGA did not improve the osseointegration process in this experimental model.
Resumo:
The aim of this study was to perform a photoelastic analysis of stress distribution on straight and angulated implants with different crowns (screwed and cemented). Three models were made of photoelastic resin PL-2: model 1: external hexagon implant 3.75 x 10.00 mm at 0 degrees; model 2: external hexagon implant 3.75 x 10.00 mm at 17 degrees; model 3: external hexagon implant 3.75 x 10.00 mm at 30 degrees. Axial and oblique (45 degrees) load (100 N) was applied with a universal testing machine. The photoelastic fringes on the models were recorded with a digital camera and visualized in a graphic software for qualitative analysis. The axial loading generated the same pattern of stress distribution. The highest stresses were concentrated between medium and apical thirds. The oblique loading generated a similar pattern of stress distribution in the models with similar implant angulation; the highest stress was located on the cervical region opposite to implant angulation and on the apical third. It was concluded that the higher the implant angulation, the higher the stress value, independent of crown type. The screwed prostheses exhibited the highest stress concentration. The oblique load generated higher stress value and concentration than the axial load.
Resumo:
This article reports the 20-month clinical outcome of the use of 4 zygomatic implants with immediate occlusal loading and reverse planning for the retreatment of atrophic edentulous maxilla after failed rehabilitation with autogenous bone graft reconstruction and maxillary implants. The intraoral clinical examination revealed mispositioned and loosened implants underneath a maxillary complete denture. The panoramic radiograph showed 6 maxillary implants. One implant was displaced into the right maxillary sinus, and the implant anchored in the region of tooth 21 was fractured. The other implants presented peri-implant bone loss. The implants anchored in the regions of teeth 21 to 23 and 11 to 13 were first removed. After 2 months, the reverse planning started with placement of 4 zygomatic fixtures, removal of the implants migrated into the sinus cavity and anchored in the region of tooth 17, and installation of a fixed denture. After 20 months of follow-up, no painful symptoms, peri-implant inflammation or infection, implant instability, or bone resorption was observed. The outcomes of this case confirm that the zygoma can offer a predictable anchorage and support function for a fixed denture in severely resorbed maxillae.