197 resultados para High Definition Finite Difference Time Domain
Resumo:
The increased availability of soil water is important for the management of non-irrigated orange orchards. The objective of this study was to evaluate the availability of soil water in a Haplorthox (Rhodic Ferralsol) under different tillage systems used for orchard plantation, mulch management and rootstocks in a "Pera" orange orchard in northwest Parana, Brazil. An experiment in a split-split-plot design was established in 2002, in an area cultivated with Brachiaria brizantha grass in which three tillage systems (no tillage, conventional tillage and strip-tillage) were used for orchard plantation. This grass was mowed twice a year between the rows, representing two mulch managements in the split plots (no mulching and mulching in the plant rows). The split-split-plots were represented by two rootstocks ("Rangpur" lime and "Cleopatra" mandarin). The soil water content in the plant rows was evaluated in the 0-20 cm layer in 2007 and at 0-20 and 20-40 cm in 2008-2009. The effect of soil tillage systems prior to implantation of orange orchards on soil water availability was less pronounced than mulching and the rootstocks. The soil water availability was lower when "Pera" orange trees were grafted on "Cleopatra" mandarin than on "Rangpur" lime rootstocks. Mulching had a positive influence on soil water availability in the sandy surface layer (020 cm) and sandy clay loam subsurface (20-40 cm) of the soil in the spring. The production of B. brizantha between the rows and residue disposal in the plant rows as mulch increased water availability to the "Pera" orange trees.
Resumo:
Objetivou-se com o presente trabalho, estabelecer a relação entre os pigmentos fotossintéticos extraídos em DMSO e as leituras obtidas no clorofilômetro portátil ClorofiLOG® 1030, gerando modelos matemáticos capazes de predizer os teores de clorofila e de carotenóides em folhas de mamoneira. O trabalho foi conduzido na Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Algodão, situada em Campina Grande, Estado da Paraíba, em outubro de 2010. Para a análise indireta, foi utilizado um equipamento portátil, sendo realizada a leitura em discos foliares com diferentes tonalidades de verde, sendo feita, nesses mesmos discos, a determinação da clorofila pelo método clássico. Para a extração da clorofila, utilizaram-se 5 mL de dimetilsulfóxido (DMSO), a qual foi mantida em banho-maria a 70ºC, por 30 minutos, e retirou-se 3 mL da alíquota para leitura em espectrofotômetro nos comprimentos de onda de 470, 646 e 663 nm. Os dados foram submetidos à análise da variância e regressão polinomial. A leitura obtida no clorofilômetro portátil foi a variável dependente, e os pigmentos fotossintéticos determinados pelo método clássico foi a variável independente. Os resultados indicaram que o clorofilômetro portátil ClorofiLOG® 1030, associado a modelos matemáticos, permitiu estimar a concentração dos pigmentos fotossintéticos, exceto a clorofila b, com alta precisão, com economia de tempo e com reagentes normalmente utilizados nos procedimentos convencionais.
Resumo:
Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The capacitor-commutated converter (CCC) has frequently been used in the conception of HVDC systems connected to busbars with low short circuit level. This alternative arrangement, in substitution to the conventional ones, guarantees less sensitive operational conditions to problems related with the commutation failure in the inverters besides supplying part of the reactive energy to be compensated. Studies related with its performance in steady and transient states have been presented in several works, however its behavior as harmonic source is still little explored. This work presents preliminary studies focusing the generation of characteristic harmonics by this type of converter. Subjects related with the amplification of the harmonic magnitudes are investigated and compared considering similar arrangements of conventional static converters (LCC) and CCC schemes. It is also analyzed the harmonic generation on the dc side of the installation and its influence on the ac side harmonics. The results are obtained from simulations in the time domain in PSpice environment and they clearly illustrate the operational differences between the L CC and the CCC schemes with regard to characteristic harmonic generation.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a hybrid way mixing time and frequency domain for transmission lines modelling. The proposed methodology handles steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behaviour. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents an easy and practical procedure to model a three-phase transmission line directly in time domain, without the explicit use of inverse transforms. The proposed methodology takes into account the frequency-dependent parameters of the line, considering the soil and skin effects. In order to include this effect in the state matrices, a fitting method is applied. Furthermore the accuracy of proposed the developed model is verified, in frequency domain, by a simple methodology based on line distributed parameters and transfer function related to the input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust analytic integration procedure to solve the state equations, enabling transient and steady-state simulations. The results are compared with those obtained by the commercial software Microtran (EMTP), taking into account a three-phase transmission line, typical in the Brazilian transmission system.
Resumo:
This article shows a transmission line model for simulation of fast and slow transients, applied to symmetrical or asymmetrical configurations. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents a practical procedure to model three-phase transmission lines directly in time domain, without the explicit or implicit use of inverse transforms. In three-phase representation, analysis modal techniques are applied to decouple the phases in their respective propagation modes, using a correction procedure to set a real and constant matrix for untransposed lines with or without vertical symmetry plane. The proposed methodology takes into account the frequency-dependent parameters of the line and in order to include this effect in the state matrices, a fitting procedure is applied. To verify the accuracy of the proposed state-space model in frequency domain, a simple methodology is described based on line distributed parameters and transfer function associated with input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust integration procedure to solve the state equations, enabling transient and steady-state simulations. The results obtained by the proposed methodology are compared with several established transmission line models in EMTP, taking into account an asymmetrical three-phase transmission line. The principal contribution of the proposed methodology is to handle a steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behavior, by a practical procedure applied directly in time domain for symmetrical or asymmetrical representations. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
In this paper is shown the development of a transmission line, based on discrete circuit elements that provide responses directly in the time domain and phase. This model is valid for ideally transposed rows represent the phases of each of the small line segments are separated in their modes of propagation and the voltage and current are calculated at the modal field. However, the conversion phase-mode-phase is inserted in the state equations which describe the currents and voltages along the line of which there is no need to know the user of the model representation of the theory in the field lines modal.
Resumo:
This paper shows the insertion of corona effect in a transmission line model based on lumped elements. The development is performed considering a frequency-dependent line representation by cascade of pi sections and state equations. Hence, the detailed profile of currents and voltages along the line, described from a non-homogeneous system of differential equations, can be obtained directly in time domain applying numerical or analytic solution integration methods. The corona discharge model is also based on lumped elements and is implemented from the well-know Skilling-Umoto Model.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.
Resumo:
Background: the associations between autonomic function and biventricular function in patients with the indeterminate form of Chagas disease remains to be elucidated.Methods: In 42 asymptornatic patients and 19 healthy volunteers, the autonomic function was assessed by time domain indices of heart rate variability (HRV), analyzed for 24 h; the right ventricular function was assessed by fraction area change, right ventricle shortening, and systolic excursion of the tricuspid valve; and the left ventricular function was assessed by ejection fraction and transmittal flow velocities. Data were expressed as mean SD or medians (including the lower quartile and upper quartile). Groups were compared by Student's t or Mann-Whitney U test. Autonomic and ventricular function were correlated by Pearson's or Spearman's correlation coefficient. The level of significance was 5%.Results: Right and left ventricular systolic function indexes were comparable between groups. Transmittal flow velocities were decreased in the Chagas disease group (p < 0.05). The patients presented impaired HRV as indicated by the values of SDNN-day (80 (64-99) ms vs. 98 (78-127) ms; p = 0.045), SDNNI-24 It (54 (43-71) vs. 65 (54-105) ms; p = 0.027), SDNNI-day (49 (42-64) vs. 67 (48-76) ms; p = 0.045), pNN50-day (2.2 (0.7-5)% vs. 10 (3-11)%; p = 0.033); and pNN50-24 It (3 (1-7)% vs. 12 (8-19)%; p = 0.013). There were no correlations between the left ventricular diastolic indices and autonomic dysfunctional indices (p > 0.05).Conclusion: Patients with the indeterminate form of Chagas disease have both dysautonomia, and left ventricular diastolic dysfunction. However, the right ventricular function is preserved. Importantly, ventricular diastolic dysfunction and dysautonomia. are independent phenomena. (c) 2005 Elsevier B.V.. All rights reserved.