75 resultados para Hertzian contact stiffness
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The problem of shock generated vibration is very common in practice and difficult to isolate due to the high levels of excitation involved and its transient nature. If not properly isolated it could lead to large transmitted forces and displacements. Typically, classical shock isolation relies on the use of passive stiffness elements to absorb energy by deformation and some damping mechanism to dissipate residual vibration. The approach of using nonlinear stiffness elements is explored in this paper, focusing in providing an isolation system with low dynamic stiffness. The possibilities of using such a configuration for a shock mount are studied experimentally following previous theoretical models. The model studied considers electromagnets and permanent magnets in order to obtain nonlinear stiffness forces using different voltage configurations. It is found that the stiffness nonlinearities could be advantageous in improving shock isolation in terms of absolute displacement and acceleration response when compared with linear elastic elements. Copyright (C) 2015 Elsevier Ltd. All rights reserved
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
BACKGROUND: Hypertension is the most prevalent comorbidity after heart transplantation (HT). Exercise training (ET) is widely recommended as a key non-pharmacologic intervention for the prevention and management of hypertension, but its effects on ambulatory blood pressure (ABP) and some mechanisms involved in the pathophysiology of hypertension have not been studied in this population. The primary purpose of this study was to investigate the effects of ET on ABP and arterial stiffness of HT recipients.METHODS: 40 HT patients, randomized to ET (n = 31) or a control group (n = 9) underwent a maximal graded exercise test, 24-hour ABP monitoring, and carotid-femoral pulse wave velocity (PWV) assessment before the intervention and at a 12-week follow-up assessment. The ET program was performed thrice-weekly and consisted primarily of endurance exercise (40 minutes) at similar to 70% of maximum oxygen uptake (Vo(2MAX))RESULTS: The ET group had reduced 24-hour (4.0 +/- 1.4 mm Hg, p < 0.01) and daytime (4.8 +/- 1.6 mm Hg, p < 0.01) systolic ABP, and 24-hour (7.0 +/- 1.4 mm Hg, p < 0.001) daytime (7.5 +/- 1.6 mm Hg, p < 0.001) and nighttime (5.9 +/- 1.5 mm Hg, p < 0.001) diastolic ABP after the intervention. The ET group also had improved Vo(2MAX) (9.7% +/- 2.6%, p < 0.001) after the intervention. However, PWV did not change after ET. No variable was changed in the control group after the intervention.CONCLUSIONS: The 12-week ET program was effective for reducing ABP but not PWV in heart transplant recipients. This result suggesfs that endurance ET may be a tool to counteract hypertension in this high-risk population. (C) 2015 International Society for Heart and Lung Transplantation. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Dermatophytes are adapted to infect skin, hair and nails by their ability to utilize keratin as a nutrient source. Trichophyton rubrum is an anthropophilic fungus, causing up to 90% of chronic cases of dermatophytosis. The understanding of the complex interactions between the fungus and its host should include the identification of genes expressed during infection. To identify the genes involved in the infection process, representational difference analysis (RDA) was applied to two cDNA populations from T. rubrum, one transcribed from the RNA of fungus cultured in the presence of keratin and the other from RNA generated during fungal growth in minimal medium. The analysis identified differentially expressed transcripts. Genes related to signal transduction, membrane protein, oxidative stress response, and some putative virulence factors were up-regulated during the contact of the fungus with keratin. The expression patterns of these genes were also verified by real-time PCR, in conidia of T. rubrum infecting primarily cultured human keratinocytes in vitro, revealing their potential role in the infective process. A better understanding of this interaction will contribute significantly to our knowledge of the process of dermatophyte infection.
Resumo:
The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. Metallic abutments can provide grayish color when in contact with thin soft tissues which may lead the implant prosthetic treatment to failure. In this context, the abutments of zirconia stand out because there is an excellent linking between esthetics and the health of peri-implant soft tissues. A consult of the published researches was made on the PubMed database from 2000 to September 2012. The including criteria were: literature reviews, clinical studies and case reports in English that focused on the response of the soft tissue in contact with zirconia implant abutments. The studies that were not in English and did not match the tackled issue were excluded. A total of 32 articles were found. According to the search strategy, just 16 articles were selected for this review. Three studies affirmed that zirconia abutments have an excellent soft tissue response; one study showed increased gingival recession with zirconia abutments and nine studies do not stand out any difference on biological behavior between titanium and zirconia abutments. Three studies affirmed that zirconia abutments provide natural gingival appearance, anatomic contour and greater esthetics. The use of zirconia abutments is recommended for anterior regions because of their greater optical properties and esthetic results and more studies should be performed and analyzed longitudinally regarding their biological response. The zirconia abutments have been established to be essential in order to achieve great esthetic results in cases of thin peri-implant soft tissues and in regions where the three-dimensional placement of implants is more superficial.
Resumo:
The purpose of this study was to evaluate the effect of occlusal contact area for loading on the cuspal defection and stress distribution in a first premolar restored with a high elastic modulus restorative material. The Rhinoceros 4.0 software was used for modeling the three-dimensional geometries of dental and periodontal structures and the inlay restoration. Thus, two different models, intact and restored teeth with three occlusal contact areas, 0.1, 0.5 and 0.75 mm(2), on enamel at the occlusal surface of buccal and lingual cusps. Finite element analysis (FEA) was performed with the program ANSYS (Workbench 13.0), which generated a mesh with tetrahedral elements with greater refinement in the regions of interest, and was constrained at the bases of cortical and trabecular bone in all axis and loaded with 100 N normal to each contact area. To analysis of maximum principal stress, the smaller occlusal contact area showed greater compressive stress in region of load application for both the intact and inlay restored tooth. However, tensile stresses at the occlusal isthmus were similar for all three tested occlusal contact areas (60 MPa). To displacement of the cusps was higher for teeth with inlay (0.46-0.48 mm). For intact teeth, the smaller contact area showed greater displacement (0.10 mm). For teeth with inlays, the displacement of the cusps were similar in all types of occlusal area. Cuspal displacement was higher in the restored tooth when compared to the intact tooth, but there were no significant variations even with changes in the occlusal contact area. RELEVANCE CLINICAL: Occlusal contacts have a great influence on the positioning of teeth being able to maintain the position and stability of the mandible. Axial loads would be able to generate more uniform stress at the root presenting a greater concentration of load application in the point and the occlusal surface. Thus, is necessary to analyze the relationship between these occlusal contacts as dental wear and subsequent occlusal interferences.
Resumo:
Veneer fracture is the most common complication in zirconia-based restorations. The aim of this study was to evaluate the mechanical behavior of a zirconia-based crown in a lower canine tooth supporting removable partial denture (RPD) prosthesis, varying the bond quality of the veneer/coping interface. Microtomography (μCT) data of an extracted left lower canine were used to build the finite element model (M) varying the core material (gold core - MAu; zirconia core - MZi) and the quality of the veneer/core interface (complete bonded - MZi; incomplete bonded - MZi-NL). The incomplete bonding condition was only applied for zirconia coping by using contact elements (Target/Contact) with 0.3 frictional coefficients. Stress fields were obtained using Ansys Workbench 10.0. The loading condition (L = 1 N) was vertically applied at the base of the RPD prosthesis metallic support towards the dental apex. Maximum principal (σmax) and von Mises equivalent (σvM) stresses were obtained. The σmax (MPa) for the bonded condition was similar between gold and zirconia cores (MAu, 0.42; MZi, 0.40). The incomplete bonded condition (MZi-NL) raised σmax in the veneer up to 800% (3.23 MPa) in contrast to the bonded condition. The peak of σvM increased up to 270% in the MZi-NL. The incomplete bond condition increasing the stress in the veneer/zirconia interface.
Resumo:
The aim of this study was to evaluate different handles used in axillary crutches with a Pressure Mapping System. The Grip Versatek system from Tekscan Inc. was used to measure the levels and the distribution of contact pressure in the hands during a simulated activity of ambulation with crutches. The sample included ten able-bodied subjects: five men and five women. The results show that the different models of handles appear to have influenced the pressure levels measured during the activity. Therefore, the measurement equipment provides parameters that allow the comparison among different designs and assess their contribution to the comprehension of the demands of ergonomic handles.
Resumo:
To assess knowledge of nursing undergraduate students about the use of contact precautions. Methodology. There were 106 nursing undergraduate students from three universities within the state of Sao Paulo. The data collection was done between April and May 2012. A questionnaire was elaborated with questions assessing knowledge regarding contact precautions. The data were submitted to statistical procedures in the package MINITAB version 16. The knowledge were rated as adequate, partially adequate and inadequate. Results. There was a predominance of females (86%) and age group between 20 and 29 years (70%). Regarding the definition of contact precaution of diseases in which these measures are used, undergraduate’s knowledge was partially adequate (92% and 44%, respectively). The knowledge was considered adequate for the preventive measures used during assistance (86%). As difficulties mentioned in the use of these measures were discomfort, lack of material, personnel and time. Conclusion. Although undergraduate students know what measures to be used in contact precaution, they do not have adequate knowledge about which diseases they should use them. The three participating universities should reflect on the quality of training for nursing students regarding biosecurity and contact precautions.
Resumo:
This study aimed to investigate the influence of storage time (0, 48 hours) of Pinus elliottii pieces and the tests to obtaining modulus of elasticity (static bending and transversal vibration) in glued laminated timber beams, produced with resorcinol based adhesive and 0.8 MPa compaction pressure. After pieces were properly prepared, part of them was used in immediate three manufacturing glulam beams, tested after adhesive cure, and part stored for 48 hours under a roof with a temperature of 25°C and relative humidity of 60% for subsequent manufacturing and testing three other glulam beams. Results of analysis of variance (ANOVA) revealed that the storage period was significant influence in modulus of elasticity obtained in static bending test (8% reduction from 0 to 48 hours). This not occurred with modulus of elasticity obtained by transversal vibration test (no significant influence). ANOVA results showed equivalence of means in both test procedures. New researches ire needed to better understand the investigated phenomenon, using new wood species, other storage conditions and a great number of samples.
Resumo:
This study focuses on analysing the effects of nonlinear torsional stiffness on the dynam-ics of a slender elastic beam under torsional oscillations, which can be subject to helical buckling.The helical buckling of an elastic beam confined in a cylinder is relevant to many applications. Someexamples include oil drilling, medical cateters and even the conformation and functioning of DNAmolecules. A recent study showed that the formation of the helical configuration is a result of onlythe torsional load, confirming that there is a different path to helical buckling which is not related tothe sinusoidal buckling, stressing the importance of the geometrical behaviour of the beam. A lowdimensional model of an elastic beam under torsional oscillations is used to analyse its dynamical be-haviour with different stiffness characteristics, which are present before and after the helical buckling.Hardening and softening characteristics are present, as the effects of torsion and bending are coupled.With the use of numerical algorithms applied to nonlinear dynamics, such as bifurcation diagramsand basins of attraction, it is shown that the nonlinear stiffness can shift the bifurcations and inducechanges in the stability of the desirable and undesirable solutions. Therefore, the proper modellingof these stiffness nonlinearities seems to be important for a better understanding of the dynamicalbehaviour of such beams.
Resumo:
The tests used to obtain the stiffness properties of wood are made with two loading cycles, as defined by the Brazilian standard ABNT NBR 7190 (Design of Timber Structures). However, the possibility of reducing the number of cycles allows decrease the operating time of the machine, resulting in reduced spending on electricity used during the tests. This research aimed to investigate, with the aid of the analysis of variance (ANOVA), the influence of the use of three load cycles to obtain the modulus of elasticity in compression parallel to grain (Ec0), in tensile parallel to the grain (Et0), in bending (Em) and in compression perpendicular to the grain (Ec90) of Angico Preto (Anadenanthera macrocarpa) wood specie. For the number of cycles and stiffness were manufactured 12 samples, totaling 144 specimens. The results of the ANOVA revealed statistical equivalence between the stiffness properties for both load cycle numbers evaluated, indicating that it is possible to carry out the tests with a single charge cycle, allowing savings in time and energy in the operation of the equipment.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV