80 resultados para Gypsum.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently the most widespread material used in dies is gypsum that together with its simple technique has very satisfactory mechanical, chemical and physical properties. However, its compactibility with the impression materials can compromise the die surface quality. In our work, we studies the hardness of the two gypsum types: Type III (die stone) and type IV (improved die stone), as well as the influence of the contact with three types of impression materials: polymerized silicone for condensation (Xantopren), polysulfide (Permlastic) and polymerized silicone by addition (Provil). As comparison parameter gypsum was used in contact with a glass surface…(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The litchi erineum mite, Aceria litchii (Keifer), is the major pest of litchi, Litchi chinensis Sonnerat (Sapindaceae). This study evaluated the effect of 11 pesticides on the survival of A. litchii as well as on the survival and reproduction of Phytoseius intermedius Evans& McFarlane, the predator most found in association with it in Brazil. The containment of A. litchii in small petri dishes whose bottoms were covered with a solidified paste made of a mixture of gypsum and activated charcoal (9: 1 in volume), kept humid, was shown to be adequate for this type of study. For the evaluation of the effect of pesticides on A. litchii, mites leaving the erinia from the pieces of litchi leaves (removed from the plants approximate to 24 h earlier) were sprayed under a Potter tower and immediately transferred to the 2.5-cm-diameter petri dishes. After 2, 12, 24, and 48 h of the application, the dishes were examined to evaluate the mite survival. The four pesticides causing the highest levels A. litchii mortality, as well as azadirachtin, were tested for the effect on P. intermedius. For this test, experimental units consisted of discs of uninfested litchi leaves also sprayed under a Potter tower before introducing the predators. Survival and oviposition of the predator were evaluated every 24 h for 5 consecutive days; viability of the eggs laid was also evaluated. Highest mortality of A. litchii occurred with the application of fenpyroximate, sulfur, abamectin, and hexythiazox. Azadirachtin was considered moderately harmful to the predator P. intermedius, whereas other pesticides were classified as harmful. Despite the low efficiency of azadirachtin in the control of the pest, its relative selectivity to P. intermedius would encourage the evaluation on field condition, especially for use in organic production systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to assess if the positioning of the impression tray could cause plaster casts distortion during gypsum setting time. fifteen pairs of master models were cast with alginate impression material and immediately poured with gypsum. impressions were allowed to set with the tray in the not inverted position (group a) or in the inverted position (group b). the plaster models were digitized using a laser scanner (3shape r-700, 3shape a/s). tooth size measurements and distances were obtained using o3d software (widialabs, brasil) measurement tools. data were analyzed by paired t test and linear regression with 5% significance. most measurements of both groups were similar, except for the lower intermolar distance. it was not possible to corroborate the presence of distortions owing to the position of the impression tray during gypsum setting time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aims at evaluating dimensional alteration of stone casts made from impressions with a standard irreversible hydrocolloid and an antimicrobial one. For this, an alginate without disinfectant (Type II Jeltrate) and other containing chlorhexidine (Type II Avagel) were used, which rose by the same regime of treatment: without disinfection; immersion; and spraying. A 1% sodium hypochlorite solution was used for 10 minutes. To obtain the impressions, a perforated impression tray was made from a standard metal model. After molding, the molds were washed in running water for 30 seconds to simulate removal of saliva. Then, with the exception of the control group, these molds were subjected to disinfection treatment. After 10 minutes they were washed again. 60 samples poured with type V special gypsum (Durone) were obtained, that were measured 3 times in a stereomicroscope (SZX12, Olympus) to record the average of dimensional alterations. The disinfection treatment did not bring significant changes in the models obtained from both alginate tested (standard p = 0.7102; with chlorhexidine p = 0.5832). The results showed a statistically significant and additional advantage of the traditional alginate on alginate with chlorhexidine, with respect to dimensional alteration (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On heat cured acrylic resins by microwaves energy the action of electromagnetic waves on methylmethacrylate promote the polymerization process. However, part of this energy is absorbed by the gypsum present in the flask and the function of this gypsum is to maintain the characteristics of specimen, nevertheless is unknown in the literature as the amount of water present in this gypsum affects the characteristics of acrylic resin. The proposal of this study was verified if dried gypsum influenced in some properties of the acrylic resins thermally activated by microwaves: presence of porosity, microhardness, roughness, flexural strength and dimensional change. Two different types of acrylic resin for complete denture were utilized: Lucitone 550 e Vipi-Wave and groups were formed: Lucitone 550, polymerization by microwave energy without gypsum treatment; Lucitone 550, polymerization by microwave energy with pretreatment gypsum; Vipi-Wave by microwave energy without gypsum treatment; Vipi Wave, polymerization by microwave energy with pretreatment gypsum; Lucitone 550 control group polymerization in hot water bath. For both situations were performed analysis of microhardness and porosity three different metallic shaped specimens were formed with followed dimensions: 2,0x2,0x2,0cm (8cm3); 2,0x2,0x1,0 (4cm3) e 2,0x2,0x0,5 (2cm3). Standardized wax specimens was used to prepare groups (n=9) and included in glass fiber flasks. The gypsum dry was made by microwave oven cycle (10min and 600W) and then the flasks were maintained in dry oven during two hours. Polymerizations of specimens were made and then polished. Wax patterns #7 obtained from the metal were embedded in plastic flask and following the processes of pressing and polymerization of the resin according to established groups. To evaluate the flexural strength, specimens 65mm x 10mm x 3.0mm from metallic patterns in bar format were made. ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The dental trade has offered dental impression and dental stone for orthodontic use ensuring accurate models. The compatibility between these materials is defined by the wetting of the model surfaces by the mixture water/stone poured over it and the influenced by the method of disinfection of model and disinfectant solution used. It was evaluated the influence of spray disinfection with sodium hypochlorite 1% on the wettability of two commercial alginate (Jeltrate ® - Dentsply and Orthoprint ® - Zhermack) at two commercial type III gypsum (Rio ® - ME and AOBussoli Orthogesso Orthogesso ®-SA). Twenty models were fabricated for each type of alginate, which were divided into two groups (water and sodium hypochlorite), receiving respectively water and sodium hypochlorite 1% spray. Each group of models was then further divided into two subgroups, and on their surface were poured 2 ml of type III gypsum (Gesso Rio® or Orthogesso®). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to ANOVA and founded statistical significance for solutions used. It was concluded that sodium hypochlorite spray improved wettability of alginates studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)