66 resultados para Flotation.
Resumo:
This study was developed to evaluate the performance of different coagulant and pH dosages by applying the use of Dissolved Air Flotation (FAD) to enable its use in effluent treatment of the extraction process of palm oil. The study was developed in the laboratory, where studies about emulsions stability were made for the production of a synthetic effluent which best suit the characteristics of raw effluent. The synthetic water that would be used in the tests of FAD was produced, once the stability and characterization which best approached the raw wastewater was obtained. Trials tested three coagulant doses, combined with various pH ranges and five upward velocities (Va), finding an optimal range of this combination. Some operating parameters such as time and gradient of rapid mixing (20 s / 1000 s-1), time and gradient flotation (15 min / 60 s-1), chamber pressure saturation (450 kPa) and recirculation rate (20%) were set. In this way, samples were collected for analysis of the removal of turbidity parameters, suspended solids and oils and greases. This one is obtained by a correlation turbidity x oils and greases, referring to the previous analysis. The degree of removal obtained were 73,97% for turbidity, 51,4% for total suspended solids and 86,2% for oils and greases. Removal rates may be increased in later studies, by ranging the velocity gradient and flocculation parameters and the recirculation ratio, and by using lower flotation speeds to these effluent characteristics.
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The main article aim was to investigate the collecting system of a dissolved air flotation (DAF) unit in pilot scale. Referring to the collecting system position, two options were analyzed: (i) top manifold and (ii) bottom manifold, pipes or plates. Qualitative and quantitative essays were performed, as image and stimulusresponse tests, respectively. The results of the essays standardized were adjusted by N-continuous stirred tank reactors in series and theoretical models of dispersion (low and high). The bottom manifold (plates with orifices) was more appropriate. The results pointed out that the N-continuous stirred tank reactors in series model was more adequate to describe the hydrodynamic behavior of the DAF unit.
Resumo:
Hookworms are parasitic nematodes that cause anemia and intestinal infections in dogs, especially with large worm burdens. However, the serum protein profile of this parasitological disease is still poorly understood. The present study was design to evaluate 80 asymptomatic dogs (age; 8 months–2 years) to detect the presence of the hookworm thin-shelled, morulated eggs in faeces using faecal flotation and to evaluate the serum protein fractions determined by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). Forty dogs had an elevated quantity of eggs in faeces (+++) (PD) and 40 dogs were healthy (HD). Infected dogs showed significant increases for IgG estimated concentrations (PD 1.79±0.8 g/dL and HD 1.44±0.72 g/dL, p= 0.04), for ceruloplasmin estimated concentrations (PD 19±15 mg/dL and HD 5±3.5 mg/dL, p=0.0001), for alpha 1-acid glycoprotein estimated concentrations (PD 31.4±17.9 mg/dL and HD 13.5±12.1 mg/dL, p=0.0001) and for a non-identified protein of 23 kDa estimated concentrations (PD 641.5±194.9 mg/dL and HD 519.8± 197.9 mg/dL, p=0.007). Dogs with hookworm infection showed significant differences in the serum protein profile when compared to healthy animals.