254 resultados para Etch adhesives


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The information about the knowledge and usage of denture adhesives is still limited, particularly in Brazilian populations. Objective: The purpose of this study was to investigate the aspects related to the use or nonuse of denture adhesives by complete denture wearers. Material and method: Questionnaires were applied to 100 bimaxillary complete denture wearers concerning their usage of denture adhesives. The survey was carried out according to three categories: those who had never tried adhesive, those who had tried adhesive at least once but no longer used it, and those who currently used it. Result: Of the 100 participants, 80% had never tried adhesives, 16% had tried at least once but no longer used it and 4% had used on a regular basis. Conclusion: Within the limitations of this study, the results of this subjective assessment suggest that within the participants that had never tried adhesives, 77.5% inform that the adhesive is not needed, and all participants who regularly use it inform its efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem Masticatory performance analysis of conventional complete denture wearers who use denture adhesives is scarce in the dental literature. Purpose The purpose of this study was to assess the effect of the use of 2 denture adhesives on the masticatory performance of conventional complete denture wearers by means of a crossover study. Material and methods Forty individuals who were edentulous received new maxillary and mandibular complete dentures, and, after an adaptation period, were submitted to masticatory performance analysis without denture adhesive (control). The participants were randomly divided and assigned to 2 protocols: protocol 1, denture adhesive 1 (Ultra Corega cream tasteless) use during the first 15 days, followed by no use of denture adhesive over the next 15 days (washout), and then use of denture adhesive 2 (Ultra Corega powder tasteless) for 15 days; protocol 2, denture adhesive 2 (Ultra Corega powder tasteless) use during the first 15 days, followed by no use of denture adhesive during the next 15 days (washout), and then use of denture adhesive 1 (Ultra Corega cream tasteless) for 15 days. The masticatory performance was assessed immediately after the use of denture adhesive by means of the sieve method, in which participants were instructed to deliberately chew 5 almonds for 20 chewing strokes. Masticatory performance was calculated by the weight of comminuted material that passed through the sieves. Data were analyzed by a 1-way ANOVA for paired samples and the multiple comparison of means by using the Bonferroni test (α=.05). Results A significant increase in masticatory performance was noted after using the Ultra Corega cream (mean, 32.6%) and Ultra Corega powder (mean, 31.2%) when compared with the control group (mean, 19.8%) (P<.001). No significant difference was found between the 2 denture adhesives evaluated. Conclusion The use of denture adhesive improved the masticatory performance of conventional complete denture wearers. No difference was found in masticatory performance with the use of cream or powder denture adhesive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present paper was to determine the effect of different types of ionizing radiation on the bond strength of three different dentin adhesive systems. Materials and Methods: One hundred twenty specimens of 60 human teeth (protocol number: 032/2007) sectioned mesiodistally were divided into 3 groups according to the adhesives systems used: SB (Adper Single Bond Plus), CB (Clearfil SE Bond) and AP (Adper Prompt Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000 mW/cm2). Customized elastomer molds (0.5 mm thickness) with three orifices of 1.2 mm diameter were placed onto the bonding areas and filled with composite resin (Filtek Z-250), which was photoactivated for 20 s. Each group was subdivided into 4 subgroups for application of the different types of ionizing radiation: ultraviolet radiation (UV), diagnostic x-ray radiation (DX), therapeutic x-ray radiation (TX) and without irradiation (control group, CG). Microshear tests were carried out (Instron, model 4411), and afterwards the modes of failure were evaluated by optical and scanning electron microscope and classified using 5 scores: adhesive failure, mixed failures with 3 significance levels, and cohesive failure. The results of the shear bond strength test were submitted to ANOVA with Tukey's test and Dunnett's test, and the data from the failure pattern evaluation were analyzed with the Mann Whitney test (p = 0.05). Results: No change in bond strength of CB and AP was observed after application of the different radiation types, only SB showed increase in bond strength after UV (p = 0.0267) irradiation. The UV also changed the failure patterns of SB (p = 0.0001). Conclusion: The radio-induced changes did not cause degradation of the restorations, which means that they can be exposed to these types of ionizing radiation without weakening the bond strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the durability of bond strength to enamel using total-etch (Single Bond/SB) and self-etch (Clearfil SE Bond/CSEB) adhesives associated with neody-mium: yttrium-aluminu- garnet (Nd:YAG) laser irradiation through the uncured adhesives.Methods: Bovine incisors were worn to expose an area of enamel and were divided into four groups: group 1 (control) SB + polymerization; group 2 (control) CSEB + polymerization; group 3 (laser) - B + Nd:YAG laser (174.16 J/cm(2)) + polymerization; and group 4 (laser) CSEB + Nd:YAG (174.16 J/cm(2)) + polymerization. Blocks of composite were fabricated and stored for 24 hours or 12 months, sectioned into beams, and submitted to microtensile tests. Results were analyzed by three-way analysis of variance (ANOVA) (adhesive, technique, and storage time) and Tukey tests.Results: ANOVA revealed significant differences for adhesive 3 technique and technique 3 storage time (p<0.05). The mean values (MPa) for interaction adhesive x technique (standard deviation) were as follows: SB/control = 35.78 (6.04)a; SB/laser = 26.40 (7.25)b, CSEB/control = 26.32 (5.71)b, CSEB/laser = 23.90 (7.49)b. For interaction technique x storage time the mean values were as follows: control/24 hours = 32.58 (6.49)a; control/12 months = 29.52 (8.38)a; laser/24 hours = 29.37 (5.71)a; laser/12 months = 20.92 (6.5)b. Groups with the same letters showed no statistically significant differences.Conclusion: Scanning electron microscope analysis showed evident areas of micromorphological alterations in lased samples after 12 months of water storage. Nd: YAG laser irradiation of enamel through unpolymerized totaletch adhesive significantly reduced bond strength compared with the control. Bond strength decreased when enamel samples irradiated with Nd: YAG laser through unpolymerized adhesives were stored in water for 12 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Length of resin tags yielded by utilization of an one-step conventional adhesive system and self-etching adhesive system on unground enamel was observed. In study Groups I and III, the enamel surface was etched for 60 seconds with 35% phosphoric acid gel and adhesive systems PQ1 (Ultradent Products, Inc) and Adper Prompt L Pop (3M/ESPE) were applied. Adper Prompt L Pop (3M/ESPE) was also applied in Group II in accordance with the manufacturer's recommendations. After application of these adhesive systems to dental enamel, specimens were prepared for light microscopy analysis to ascertain degree of penetration (x400). The results were submitted to an analysis of variance at the 5% level; whenever there was significance, the Tukey test was applied at the 5% level. It was found that acid etching prior to application of conventional and self-etching adhesive materials provided higher penetration of the adhesive into the unground enamel surface compared to that achieved solely by application of self-etching adhesive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the adhesion ability of eucalyptus lumber from three tillage systems, using adhesives: resorcinol formaldehyde and two adhesives in water emulsion based on vinyl poly-acetate. The management systems were characterized by three strata, the stratum one (E1) characterized by wood from coppice and 70 months of age, the stratum two (E2) characterized by wood and retirement age of 166 months and stratum three (E3), also characterized by retirement at 70 months of age. The wood was derived from a random mixture of the first two sawn logs, each three feet from the base, which comprised three treatments on the adhesive used. We evaluated the shear strength by compression tests and the percentage of wood failure in the glue line. Based on the results obtained, it can be said that the adhesion had satisfactory performance with all the resins used, and the average values of shear strength of the glue line were shown to be equivalent to the shear strength of solid wood only for the samples which adhered with 'Wonderbond' adhesive and also provide higher values for wood failure (97.64%). The highest density present in the wood of the second stratum (E2) influenced only sticking with the resorcinol formaldehyde resin. For polyvinyl acetate (Cascorez 2590), shear values decreased in the third management condition (E3).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass ionomer cements are widely used in dentistry as restorative materials and adhesives for composite restorations. However, the results of genotoxicity studies using these materials are inconclusive in literature. The goal of this study was to examine the genotoxic and cytotoxic potential of three different glass ionomer cements available commercially (Ketac Cem, Ketac Molar and Vitrebond) by the single cell gel (comet) assay and trypan blue exclusion test, respectively. For this, such materials were exposed to Chinese hamster ovary (CHO) cells in vitro for 1 h at 37 degrees C. Data were assessed by Kruskall-Wallis nonparametric test. The results showed that the powder from Ketac Molar displayed genotoxicity only in the maximum concentration evaluated (100 mu g/mL). In the same way, the liquid from Vitrebond at 0.1% dilution caused an increase of DNA injury. Significant differences (P < 0.05) in cytotoxicity provoked by all powders tested of glass ionomer cements were observed for exposure at 1000 mu g/mL concentration. With respect to liquids of glass ionomer cements evaluated, the major toxic effect on cell viability was produced at 10%, beginning at the dilution of 0.5% for Vitrebond. Taken together, we conclude that some components of glass ionomer cements show both genotoxic and cytotoxic effects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass-ionomer cements are widely used in dentistry as restorative materials and adhesives for composite restorations. A number of genotoxicity studies have been conducted using these materials with results conflicting so far. Thus, the approach was aimed to look at the genotoxic and cytotoxic potential of three different glass-ionomer cements available commercially (Ketac Cem, Ketac Molar and Vitrebond) by the single cell gel (comet) assay and trypan blue exclusion test, respectively. For this, such materials were exposed to mouse lymphoma cells in vitro for 1 h at 37 degrees C. Data were assessed by Kruskall-Wallis non-parametric test. The results showed that all powders assayed did not show genotoxic effects. on the other hand, the liquid from Vitrebond at 0.1% dilution caused an increase of DNA injury. Significant statistically differences (P < 0.05) in cytotoxicity provoked by all powders tested were observed for exposure at 1000 mu g mL(-1) concentration and 100 mu g mL(-1) for Ketac Molar. With respect to liquids of glass-ionomer cements evaluated, the major toxic effect on cell viability was produced at 1%, beginning at the dilution of 0.5% for Vitrebond. Taken together, these results support the notion that some components of glass-ionomer cements show both genotoxic and cytotoxic effects in higher concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The effect of methyl methacrylate (MMA) monomer on the bond strength of three types of denture base resins (Acron MC, Lucitone 550 and QC-20) to two types of acrylic teeth (Biotone and Trilux) was evaluated. Twenty specimens were produced for each denture base resin/acrylic tooth combination and were randomly divided into control (acrylic teeth received no surface treatment) and experimental groups (MMA was applied to the surface of the acrylic teeth for 180 s) and were submitted to shear tests (1 mm/mm). Data (MPa) were analyzed using three-way ANOVA/Student's test (alpha = 0.05). MMA increased the bond strength of Lucitone denture base resins and decreased the bond strength of QC-20. No difference was detected for the bond strength of Acron MC base resin after treatment with MMA. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment.Objective: The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants.Materials and methods: The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system.Conclusion: The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)