144 resultados para Electrode contacts
Resumo:
A rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Cathodic stripping voltammetry (CSV) and accumulation at the hanging mercury drop electrode are reviewed briefly. Proposals in a recent IUPAC technical report are considered. Three recent developments in CSV are discussed: the adaptation of CSV methods developed for use with the hanging mercury drop electrode for use with screen-printed carbon electrodes in disposable sensors, the use of reactive accumulation, and the chemometric use of kinetic methods of determination with pulse methods in CSV.
Resumo:
The voltammetric determination of rutin in 0.04 mol l(-1) B-R buffer (pH 4.0) by square wave voltammograms (+0.41 V vs. Ag/AgCl(sat.)) at a poly glutamic acid modified glassy carbon electrode was found to be several orders of magnitude lower than that on a bare glassy carbon electrode. Rutin can be preconcentrated on the films of poly glutamic acid and presented linear relationship from concentration of 7 x 10(-7) to 1 x 10(-5) mol l(-1) in 0.04 mol l(-1) B-R buffer pH 4.0. The method was successfully applied to the determination of rutin in pharmaceutical formulation without any pretreatment.
Resumo:
Prussian blue [PB, iron(III) hexacyanoferrate(II)] films are effective for the electrocatalysis of the persulfate (peroxodisulfate)/sulfate redox system. This has been exploited in the voltammetric determination of persulfate anions using a PB-modified platinum disc electrode. A linear correlation between electrocatalytic current and persulfate concentration was found for the range 5 x 10(-5) to 3 x 10(-3) mol dm(-3), using 0.100 mol dm(-3) potassium chloride as supporting electrolyte at pH 4. This analytical method has the advantages of speed and ease of operation in relation to traditional titrimetric methods for persulfate determination. The applicability of the method to the determination of persulfate in a commercial hair bleaching 'booster' product is demonstrated. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Glassy carbon electrodes were coated with films of poly( glutamic acid) ( PG), and the modified electrode proved to be very effective in the oxidation of caffeic acid. The performance of the film was also tested with ascorbic acid, coumaric acid, ferulic acid, sinapic acid and chlorogenic acid. At pH 5.6, all the hydroxycinnamic acids yield a higher peak current intensity when oxidized after incorporation in the PG-modified electrode, and only the oxidation of ascorbic acid exhibits overpotential reduction. At pH 3.5 only caffeic and chlorogenic acid are incorporated in the modified electrode and exhibit a well-defined oxidation wave at +0.51 V and +0.48 V, which is the base for their determination. Linear calibration graphs were obtained from 9 x 10(-6) mol L-1 to 4 x 10(-5) mol L-1 caffeic acid by linear voltammetric scan and from 4 x 10(-6) mol L-1 to 3 x 10(-5) mol L-1 by square wave voltammetric scan. The method was successfully applied to the determination of caffeic acid in red wine samples without interference from other hydroxycinnamic acids or ascorbic acid.
Resumo:
A highly sensitive amperometric biosensor for determination of carbamate pesticides directly in water, fruit and vegetable samples has been evaluated, electrochemically characterized and optimized. The biosensor strip was fabricated in screen printed technique on a ceramic support using silver-based paste for reference electrode, and platinum-based paste for working and auxiliary electrodes. The working electrode was modified by a layer of carbon paste mixed with cobalt(II) phthalocyanine and acetylcellulose. Cholinesterase (ChE) enzymes with low enzymatic charge were immobilized on this layer. The operational simplicity of the biosensor consists in that a small drop (similar to 50 mu l) of substrate or sample is deposited on a horizontally positioned biosensor strip representing the microelectrochemical cell. The working potential of the biosensor was 370 mV versus Ag/AgI on a ship reference electrode preventing the interference of electroactive species which are oxidable at more positive potentials. The biosensor was applied to investigate the degradation of two reference ChE inhibitors in freeze dried water under different storage conditions and for direct determination of some N-methylcarbamates (NMCs) in fruit and vegetable samples at ppb concentration levels without any sample pretreatment. A comparison of the obtained results for the total carbamate concentration was done against those obtained using HPLC measurements. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode
Resumo:
The PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0 x 10(-6) to 1.0 x 10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49 x 10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5 x 10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
This paper reports results from electrochemical evaluations of electrodes used as cathodes for a hydrogen evolution reaction and anodes in Ni-MH batteries that had been surface-modified by micro-encapsulation, co-deposition and sol-gel methods. The surface modifications produced actual improvements in the corresponding electrochemical reactions by enhancing the performance and/or the mechanical stability of the electrode material. (c) 2005 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserved.
Resumo:
This paper describes the construction of an electrode of the second kind, Pt\Hg\Hg-2(Salic)(2)\Graphite, sensitive to salicylate. This electrode responds to the salicylate ion with a sensivity of 58.66 mV/decade over the range 6.0x10(-4) - 1.0x10(-1) mol/l at pH 6.0 and an ionic strength of 0.500 - 3.00 mol/l, adjusted with NaClO4. The electrode is easily constructed, shows a fast response time, is low in cost, has excellent response stability, and has a lifetime greater than 18 months, which is much longer than those reported earlier for other systems. The influence of 10 different carboxylate and inorganic anions on the electrode response showed that there was negligible interference by most of these ions. It was used to determine aspirin in tablets (after hydrolysis of acetylsalicylic acid to salicylate) by means of the standard additions method. The results obtained using this electrode for aspirin determination, in three different samples of antithermic drugs, compared favorably with the results given by the British Pharmacopoeia method.
Resumo:
Thermogravimetry (TG), cyclic voltammetry (CV) and other analytical techniques were used to study the reactions of mercury with Pt-30% Ir alloy. The results allowed to suggest that an electrodeposited mercury film interacts with the substrate and when subjected to heat or electrochemical removal at least four mass loss steps or five peaks appeared during the mercury desorption process. The first two steps were attributed to Hg(0) removal probably from the bulk and from the adsorbed monolayer which wets the electrode surface. These two processes are responsible for peaks D and F in the cyclic voltammograms. The last two peaks (G, H) in CV were ascribed to the intermetallic compound decomposition. In TG curves, the last two steps were attributed to the PtHg4 (third step), and PtHg2 decomposition followed by Hg removal from the subsurface. The PtHg2 was formed by an eutectoide reaction: PtHg -> PtHg2+Hg(Pt-Ir). The Hg diffused to the subsurface was not detectable by cyclic voltammetry.
Resumo:
A mercury-free electrode chemically modified with carbon paste containing dimethylglyoxime was used for determination of nickel in fuel ethanol. The instrumental parameters and composition of the modified paste were optimized. The analytical curve for nickel determination from 5.0 x 10(-9) to 5.0 x10(-7) mol(-1) was obtained using 25 min of accumulation time. The detection limit and amperometric sensitivity obtained for this method were 2.7 x 10 mol(-1) and 5.2 x 10(8) mu A mol(-1) L, respectively. The values for nickel concentration in four commercial samples of fuel ethanol were obtained in the range of 1.1 x 10(-8) to 6.9 x 10(-8) mol(-1). A comparison to graphite furnace atomic absorption spectrometry (GFAAS) was performed for nickel determination in commercial samples of ethanol.
Resumo:
A salt elimination reaction between [YCl3(THF)(3.5)] and 1 or 2 equiv. of Tl(Tp(Ms*)) [Tp(Ms*) = HB(3-mesitylpyrazolyl)2(5-mesitylpyrazolyl)(-)] leads in both cases to single metathesis, giving a mixture of the mono-Tp(Ms*) complex [YCl3(Tp(Ms*))Tl] (1) and another complex, [YCl2(Tp(Ms* *))] (2) [Tp(Ms* *) = HB(3-mesitylpyrazolyl)(5-mesitylpyrazolyl)(2)(-)], that results from the transfer of a second mesityl group to the 5-position of the pyrazolyl ring. The solid-state structure of 1 shows a unique ate dimeric structure with the TV cations coordinated by two mu(2)- and two mu(3)-bridging Cl atoms as well as two eta(3)-mesityl ligands. ((C) Wiley-VCH Verlag GmbH & Co. KGaA, 69451 Weinheim, Germany, 2004).
Resumo:
The electrochemical reduction of two reactive dyes: Procion Red HE-3B 9 (RR120) and Procion Green HE-4BD (RG19) was investigated using cyclic voltammetry, differential pulse and DC, polarography, chronoamperometry and controlled potential electrolysis at mercury electrodes. The bis-azo groups of the RR120 dye are reduced together in one single step of four electrons, the bis-azo groups of the RG19 dye are reduced in two steps owing to the difference in the electron densities promoted by the different substituents in the benzene rings adjacent to the azo groups. The bis-monochlorotriazine reactive groups in both dyes are reduced only in acidic medium in their protonated form, leading to the reduction of the triazine groups. The reduction mechanism of both reactive dyes is discussed. Both dyes can be quantified in aqueous medium by differential pulse polarography in the concentration range of 1 x 10(-7) mol L-1 to 1 x 10(-5) mol L-1 by monitoring the reduction of the chromophore group or the reactive group.