94 resultados para Electroanalytical Chemistry
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. Levels greater than 3 mu g/mL serum have hitherto been considered to indicate pathology, but there is increasing interest in assessments between 0.1 and 10 mu g/mL, which have been found to correlate with severity of risk for cardiovascular disease. We report herein the generation of both antibody and Affimer based impedance immunoassays for CRP that are substantially more sensitive than clinically utilized immunonephelometry and immunoturbidity assessments. Significant in this study is not only the use of a constrained peptide to detect a clinically important target but also that derived electrochemical impedance assays can be highly sensitive even with probes whose relatively weak (mu M) affinities are not amenable to target detection by surface plasmon resonance (SPR). Key to this finding is acknowledging that receptive surfaces of comparatively low initial steric bulk and charge transfer resistance are especially primed to be highly responsive to target binding in electroanalytical assays of this type.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The measurement of nitrogen dioxide at the parts-perbillion level is described. The experimental arrangement consists of two optical fibers placed on opposite sides of and in contact with a liquid film (14-57 μL in volume) supported on a U-shaped wire guide and two tubular conduits (one of which constitutes the means for the delivery of the liquid), light from a green (555 nm) light-emitting diode enters the liquid film, composed of Griess-Saltzman reagent. The transmitted light is measured by a referenced photodetection arrangement. Sample gas flows past the droplet at a low flow rate (typically 0.10-0.25 L/min). The response is proportional to the sampling period and the analyte concentration. The limit of detection for this nonoptimized arrangement is estimated to be <10 ppb by volume for a 5 min sample. Some unusual characteristics are observed. The initial absorbance, when most of the analyte/reaction product is still near the surface, is higher than that when the content of the droplet is fully mixed. The signal depends on the sample flow rate in a nonmonotonic fashion, first increasing and then decreasing with increasing sampling rate; the specific chemistry involved in the collection and determination of NO2 may be responsible.
Resumo:
Chemical analyses for biotites and their host rocks from the Cabreúva (three facies) and Salto (five facies) intrusions from the multiple-centered rapakivi Itu Complex, State of São Paulo, Brazil, are presented and compared. The Cabreúva intrusion comprises different kinds of mainly even-grained biotite and hornblende-bearing syenogranites, monzogranites and quartz syenites and the Salto intrusion several types of mainly porphyritic biotite syenogranites, some of them hornblende-bearing. The biotites from the Salto intrusion (S-micas) show a more restricted composition than those from the Cabreúva intrusion (C-micas). This reflects the chemical variability of the two bodies which is smaller in the Salto intrusion and larger in the Cabreúva pluton. In the AlIV x Fet/(Fet+Mg) diagram the S- and C-micas show similar AlIV contents, around 2.2-2.3, but C-micas have higher Fet/(Fet+Mg) ratios (0.7-0.9) compared to those of S-micas (0.5-0.6). In the Mg:(Al+Fe+3+Ti):(Fe+2+Mn) diagram the S-micas are defined as Fe+2-biotites and the C-micas occupy the area between the Fe+2-biotites and the siderophyllite/lepidomelane fields, slightly overlapping the latter. In the Al2O3 × FeOt, MgO × FeOt, Al2O3 x MgO and Alt x Mg diagrams, the S-micas always lie on the calc-alkaline/alkaline boundary (or in the subalkaline field) whereas the C-micas systematically plot in the alkaline field, reflecting the higher alkalis content of the Cabreúva intrusion. In the Fet/(Fet+Mg) x SiO2 diagram, the S-micas lie on a smooth line whereas the C-micas from the different facies are separated by distinct chemical gaps reflecting the major or minor chemical overlapping of the facies from the Salto and Cabreúva intrusions.
Resumo:
This paper presents optical and electrical measurements on plasma generated by DC excited glow discharges in mixtures composed of 95% N2, 4.8% CH4 and 0.2% H2O at pressures varying from 1.064 mbar to 4.0 mbar. The discharges simulate the chemical reactions that may occur in Titan's atmosphere in the presence of meteorites and ice debris coming from Saturn's systems, assisted by cosmic rays and high energy charged particles. The results obtained from actinometric optical emission spectroscopy, combined with the results from a pulsed Langmuir probe, show that chemical species CH, CN, NH and OH are important precursors in the synthesis of the final solid products and that the chemical kinetics is essentially driven by electronic collision processes. It is shown that the presence of water is sufficient to produce complex solid products whose components are important in prebiotic compound synthesis. © 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
The hexane extract of the stems of Raulinoa echinata afforded the sesquiterpenes germacrene D (6), 1β,6α-dihydroxy-4-(15)-eudesmene (4) and oplopanone (5); the triterpenes squalene, isomultiflorenol (7), isobauerenol (8) and friedelin (9); the protolimonoids melianone (2) and melianodiol (3); and the pyranocoumarin 3-(1′-1′-dimethylallyl)-lomatin (1), which has not been reported previously as a natural product; together with β-sitosterol. The hexane extract and some of these compounds were assayed in vitro against trypomastigote forms of Trypanosoma cruzi. Brine shrimp lethality and antimicrobial activities of the crude extract and pure compounds were also evaluated.
Resumo:
Potentiometric, amperometric and conductometric electrochemical sensors have found a number of interesting applications in the areas of environmental, industrial, and clinical analyses. This review presents a general overview of the three main types of electrochemical sensors, describing fundamental aspects, developments and their contribution to the area of analytical chemistry, relating relevant aspects of the development of electrochemical sensors in Brazil.
Resumo:
This work describes the development of a new program, named SISTAX, for the expert system SISTEMAT. This program allows anyone interested in chemotaxonomy to carry out an intelligent search for organic compounds in databases through chemical structures. When coupled with can efficient encoding system, the program recognizes skeletal types and can find any substructural constraints demanded by the user. An example of an application of the program to the diterpene class found in plants is described.
Resumo:
Silica gel with a specific area of 382 m2 g-1 and an average pore diameter of 60 Å was chemically modified with 2-amino-1,3,4-thiadiazole, for the purpose of selective adsorption of heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). The following properties of this functionalized silica gel are discussed: selective adsorption of heavy metal ions measured by batch and chromatographic column techniques, and utilization as preconcentration agent in a chemically modified carbon paste electrode (CMCPE) for determination of mercury(II). The chemical selectivity of this functional group and the selectivity of voltammetry were combined for preconcentration and determination. ©2006 Sociedade Brasileira de Química.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Eriocaulaceae is a pantropical family that comprises about 1100 species distributed in 11 genera. The infrafamilial relationships are still unsatisfactorily resolved, because of the tiny flowers and generalized morphology, which makes the taxonomy very difficult. Flavonoid and naphthopyranone profiles have proved to be important in order to contribute to the alignment of genera into the family. We here present a survey of the chemical data of Eriocaulaceae with a discussion about their contribution to the taxonomy of Eriocaulaceae. © 2008 Verlag der Zeitschrift für Naturforschung.
Resumo:
The present study was designed to analyze the effects of the association between cinnamon extract and aerobic exercise on the glycemic control and serum lipid profile of diabetic rats. Fifty Wistar male rats divided into five groups: control (C), sedentary nondiabetic rats; diabetic (D), sedentary diabetic rats; diabetic cinnamon (DC), sedentary diabetic rats that received cinnamon extract; diabetic exercise (DE), sedentary diabetic rats subjected to physical training; and diabetic cinnamon exercise (DCE), diabetic rats that received cinnamon extract and were subjected to physical training. For the induction of diabetes, the rats received alloxan. The cinnamon was administered to once a day for four weeks. The groups performed swimming exercises for one hour each day with lead overloads (3% - 5% of b.w) for five days a week for four weeks. Body weight loss was lower in the DE group compared to the other diabetic groups. The basal serum glucose of all the diabetic groups was higher compared to the control group. Group D had higher serum cholesterol concentrations compared to the DE and DCE groups. The resting blood lactate in group D was higher than the resting blood lactate in the DC and DE groups. Aerobic exercise partially counteracted the diabetic effects on body weight, serum cholesterol and blood lactate concentrations. No additional beneficial effects of cinnamon extract and aerobic exercise were observed on the parameters studied.
Resumo:
A poly glutamic acid film modified electrode exhibited a catalytic response toguanosine oxidation potential and higher peak current value. Linear concentration curve was obtained in the concentration interval of 1.0 a 10.0 μmol L-1 in 0.04 mol L-1 B-R buffer pH 2.0 with a detection limit of 0.198 μmol L-1. The electrode was used for the determination of guanosine in the potential of +1.1 V (vs. Ag/AgCl) using differential pulse voltammetry (DPV) at urine sample with good recovery. © 2010 by CEE.