193 resultados para Elasticity.
Resumo:
The objective of the present research was to investigate the ultrastructural peculiarities of the aortic wall of the rat. Seven young adult rats were used, from which fragments of the infrarenal abdominal aorta were collected. After collection, the vascular segments were fixed and sent for analysis by scanning electron microscope. The elastic lamellae appear interposed with smooth muscular fibers; this pattern was verified mainly at the medial layer structure. Among the mural elements a well defined interrelationship was established through connective lamellae of the arterial wall. The collagen lamellae mainly provided anchoring among the elastic and smooth muscular constituents. The intimal layer showed special ultrastructural features, such as a non-continuous inner elastic lamina presented in certain sites of the vascular wall, followed by endothelial pores. This mural pattern of the abdominal aorta provided support to vascular functions such as shrinkage among the laminar composition of the arterial layers, also acting in mechanical properties of the vascular wall, such as viscoelasticity and contractility - essential actions to blood vessel hemodynamics.
Resumo:
In this paper is proposed and analyzed a digital hysteresis modulation using a FPGA (Field Programmable Gate Array) device and VHDL (Hardware Description Language), applied at a hybrid three-phase rectifier with almost unitary input power factor, composed by parallel SEPIC controlled single-phase rectifiers connected to each leg of a standard 6-pulses uncontrolled diode rectifier. The digital control allows a programmable THD (Total Harmonic Distortion) at the input currents, and it makes possible that the power rating of the switching-mode converters, connected in parallel, can be a small fraction of the total average output power, in order to obtain a compact converter, reduced input current THD and almost unitary input power factor. Finally, the proposed digital control, using a FPGA device and VHDL, offers an important flexibility for the associated control technique, in order to obtain a programmable PFC (Power Factor Correction) hybrid three-phase rectifier, in agreement with the international standards (IEC, and IEEE), which impose limits for the THD of the AC (Alternate Current) line input currents. The proposed strategy is verified by experiments. © 2008 IEEE.
Resumo:
A previous work showed that viscosity values measured high frequency by ultrasound agreed with the values at low frequency by the rotational viscometer when conditions are met, such as relatively low frequency viscosity. However, these conditions strongly reduce the range of the measurement cell. In order to obtain a measurement range and sensitivity high frequency must used, but it causes a frequency-dependent decrease on the viscosity values. This work introduces a new simple in order to represent this frequency-dependent behavior.model is based on the Maxwell model for viscoelastic , but using a variable parameter. This parameter has physical meaning because it represents the linear behavior the apparent elasticity measured along with the viscosity by .Automotive oils SAE 90 and SAE 250 at 22.5±0.5oC viscosities at low frequency of 0.6 and 6.7 Pa.s, respectively,tested in the range of 1-5 MHz. The model was used in to fit the obtained data using an algorithm of non-linear in Matlab. By including the viscosity at low frequency an unknown fitting parameter, it is possible to extrapolate its . Relative deviations between the values measured by the and extrapolated using the model for the SAE 90 and SAE 250 oils were 5.0% and 15.7%, respectively.©2008 IEEE.
Resumo:
Rheology has the purpose to study the flux and deformation of materials when submitted to some tension or outer mechanical solicitation. In practice, the effective scientific field broached by rheology is restricted only to the study of homogeneous fluids behavior, in which are included eminent liquids, particles suspensions, and emulsions. The viscosity (η) and the yield stress (τ 0) are the two basic values that define the fluids' behavior. The first one is the proportionality constant that relates the shear rate (γ) with the shear stress (τ) applied, while the second indicates the minimal tension for the flowage beginning. The fluids that obey the Newton's relation - Newtonians fluids - display the constant viscosity and the null yield stress. It's the case of diluted suspensions and grate amount of the pure liquids (water, acetone, alcohol, etc.) in which the viscosity is an intrinsic characteristic that depends on temperature and, in a less significant way, pressure. The suspension, titled Cement Paste, is defined as being a mixture of water and cement with, or without, a superplasticizer additive. The cement paste has a non-Newtonian fluid behavior (pseudoplastic), showing a viscosity that varies in accord to the applied shear stress and significant deformations are obtained from a delimited yield stress. In some cases, systems can also manifest the influence of chemical additives used to modify the interactions fluid/particles, besides the introduced modifications by the presence of incorporated air. To the cement paste the rheometric rehearsals were made using the rheometer R/S Brookfield that controls shear stress and shear rate in accord to the rheological model of Herschel-Bulkley that seems to better adapt to this kind of suspension's behavior. This paper shows the results of rheometrical rehearsals on the cement paste that were produced with cements HOLCIM MC-20 RS and CPV-ARI RS with the addition of superplasticizer additives based of napthaline and polycarboxilate, with and without a constant agitation of the mixture. The obtainment of dosages of superplasticizer additives, as well as the water/cement ratio, at the cement at the fluidify rate determination, was done in a total of 12 different mixtures. It's observed that the rheological parameters seem to vary according to the cement type, the superplasticizer type, and the methodology applied at the fluidity rate determination.
Resumo:
INTRODUCTION: Soft liners have been developed to offer comfort to denture wearers. However, this comfort is compromised when there is a change in the properties of the material, causing colour change, solubility, absorption and hardening. These characteristics can compromise the longevity of soft liners. AIM: The aim of this in vitro study was to investigate the effect of ageing on both the hardness and colour change of two soft liners following accelerated ageing. METHODS: Two denture liners, one resin based (Trusoft, Bosworth, Illinois, USA) and one silicone based (Ufi Gel P, Voco GMBH, Cuxhaven, Germany), were tested in this study for both hardness (using the Shore A scale) and colour change (using the CIE L*a*b* colour scale), initially and after 1008 hours (6 weeks) of accelerated ageing. Statistical analysis was performed using the unpaired t-test with the Welch correction. RESULTS: These indicated that both materials increased in hardness and underwent colour change after accelerated ageing. The initial hardness of Trusoft was far lower than that of Ufi Gel P (18.2 Shore A units vs 34.8 Shore A units). However, for Trusoft the changes for both hardness (from 18.2 to 52.1 Shore A units) and colour change (16.85 on the CIE L*a*b* colour scale) were greater than those for Ufi Gel P, for which hardness changed from 34.8 to 36.5 Shore A units and the colour change was 5.19 on the CIE L*a*b* colour scale. CONCLUSIONS: Ufi Gel P underwent less hardness and colour change after accelerated ageing than Trusoft. On the other hand, the use of Trusoft may be preferable in cases where initial softness is a major consideration, such as when relining an immediate denture after implant surgery.
Resumo:
The study on several components of intervertebral joints is essential to understand the spine's degenerative mechanisms and to assess the best method for their treatment. For such study it is necessary to know the mechanical properties of the isolated intervertebral disc (ID) mechanical properties and, it is necessary to evaluate its stresses and strains. In order to assess the ID displacements, a fine, U-shaped blade was developed, over which two extensometers connected in a Wheatstone bridge were placed. The device was then tested on porcine spine ID, where compression loads were applied and the extremities displacements of the blade coupled to the intervertebral disc were measured. Stress/strain diagram, both on the compression and on the decompression phases, evidencing the non-linear nature of such relationship. With the experiment, it was possible to obtain approximate values of the longitudinal elasticity module (E) of the disc material and of the Poisson coefficient (n ). After several tests, E results are compatible with those obtained by others studies, with very simple and low-cost device. This experiments can be used for obtained others mechanical properties of isolated ID with precision and accuracy.
Resumo:
This paper analyses the static and dynamic behavior of the railroad track model in laboratory. Measurements of stresses and strains on a large-scale railroad track apparatus were studied. The model includes: compacted soil, representing the final layers of platform, ballast layer, and ties (steel, wooden, and pre-stressed concrete). The soil and soil ballast interface were instrumented with pneumatic stress gauge. Settlement measurement device were positioned at the same levels as the load cells. Loads were applied by hydraulic actuators, statically and dynamically. After the prescribed number of load cycles, in pre-determined intervals, stresses and strains were measured. Observations indicate that stress and strain distributions, transmitted by wooden or steel ties, behave similarly. A more favorable behavior was observed with pre-stressed concrete mono block ties. Non-linear response was observed after a threshold numbers of cycles were surpassed, showing that the strain modulus increases with the numbers of cycles. © 2009 IOS Press.
Resumo:
The determination of the reflection coefficient of shear waves reflected from a solid-liquid interface is an important method in order to study the viscoelastic properties of liquids at high frequency. The reflection coefficient is a complex number. While the magnitude measurement is relatively easy and precise, the phase measurement is very difficult due to its strong temperature dependence. For that reason, most authors choose a simplified method in order to obtain the viscoelastic properties of liquids from the measured coefficient. In this simplified method, inconsistent viscosity results are obtained because pure viscous behavior is assumed and the phase is not measured. This work deals with an effort to improve the experimental technique required to measure both the magnitude and phase of the reflection coefficient and it intends to report realistic values for oils in a wide range of viscosity (0.092 - 6.7 Pa.s). Moreover, a device calibration process is investigated in order to monitor the dynamic viscosity of the liquid.
Resumo:
Topical retinoids are used to treat photoaging; oral isotretinoin is gold standard for acne; off label indications, including photoaging, have been reported with insufficient evidence of efficacy. This is a randomized controlled phase II trial with clinical and histological assessment to evaluate efficacy and safety of oral isotretinoin for photoaging. Study population was comprised of 32 menopausal or sterilized women, aged 40-55, divided in 2 groups: A (21) received 20mg isotretinoin, 3 times per week, nightly moisturizer, and daily sunscreen, for three months; B (11) just moisturizer/sunscreen. Main outcome measures were: overall clinical assessment; profilometry, corneometer and elasticity tests in periocular regions and left forearm; before/after biopsies from left forearm in patients of B and in 10 randomly selected of A. Microscopic blinded evaluation of epidermal thickness, dermal elastosis, new collagen, p53 epidermal expression was performed by quantitative digital image analysis. All data were submitted to statistical analysis. Clinical evaluation showed slight improvement; profilometry, corneometer and skin elasticity tests presented significant difference in pre/post values (P = 0.001 to 0.028), but no differences between A/B. Histological findings and p53 expression were comparable between groups before treatment (P > 0.1); microscopic analysis showed no differences between groups for most variables, after treatment. Slight but significant difference between A/B for p53 with major reduction post isotretinoin [0.66±0.31 vs. 0.94±0.34 respectively (P = 0.04) was observed. There were minor side effects and no significant laboratory test alterations. We concluded that no significant clinical, microscopic changes but p53 epidermal expression reduction were observed. The role of ultra-violet induced p53 mutation in skin carcinogenesis reinforces retinoids chemoprevention. Oral isotretinoin seemed safe but not effective to treat photoaging. Caution should be considered for women prone to pregnancy. Further controlled studies are necessary. © 2010 The International Society of Dermatology.
Resumo:
Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.
Resumo:
Atherosclerosis is a serious chronic disease, responsible for thousands of deaths worldwide and is characterized by thickening and loss of elasticity of the arterial walls, associated with the presence of atheromatous plaques. Various risk factors act directly on predisposition to the disease, among which the following are pointed out: diabetes mellitus, arterial hypertension and inadequate diet and eating habits. More recent researches have elucidated new risk factors acting in the development of this disease, such as, for example: periodontitis, chronic renal disease and menopause. The panoramic radiograph, commonly used in dental practice, makes it possible to see calcified atherosclerotic plaques that are eventually deposited in the carotid arteries. The aim of this review article was to emphasize the dentist's important role in the detection of carotid artery atheromas in panoramic radiographs and the immediate referral of patients affected by these calcifications to doctors. In addition, the study intended to guide the dentist, especially the dental radiologist, with regard to differential diagnosis, which should be made taking into consideration particularly the triticeal cartilage when it is calcified. © Henriques et al.
Resumo:
After concluding the main phase of commercial exploration of latex (about 30 years ago), rubber wood plantations can be utilized as an alternative source of wood for sawmills and other wood based products with more aggregate value; tendency already confirmed in countries of southeastern Asia. The main purpose of this research was to evaluate the influence of dynamic modulus of elasticity veneers on the mechanical performance in the bending of plywood made from Hevea brasiliensis. For this study, rubber tree veneers were sorted in three classes of dynamic modulus of elasticity: low (from 4887-7323 MPa), medium (from 8200-8948 MPa) and high (from 10979-13010 MPa). Panels were produced according to five treatments with different veneer classes and arrangements. Results showed significant effect of the treatments in the mechanical performance in the bending of panels. Panels with better mechanical performance were produced exclusively with medium and high dynamic modulus of elasticity. Panels made with low modulus of elasticity veneers presented lower mechanical performance even when combined with high modulus of elasticity veneers.
Resumo:
The porpoise of this study was to evaluate the effects of extracorporeal shock waves in third metacarpus bone from healthy horses by determination of bone elasticity. It were used 20 Thoroughbred horses, male and female, with two years old, on top of training and selected as the state healthy. At the beginning of the experiment (D0), all animals were submitted for evaluation of bone elasticity held in the third metacarpus bone. The animals were divided into two groups (Control Group - CG and Experimental Group - EG). The application of extracorporeal shock wave therapy (ESWT) was performed on the right forelimb of the animals in the experimental group in the same place evaluated for bone elasticity and was used apparatus for extracorporeal therapy of waves with 0.15 mJ/mm2 energy flux density and 2000 pulses with E6R20 probe, with focus feature of the shock wave of 20 mm. The ESWT were repeated every 21 days, a total of three sessions (D0, D21 and D42). The analysis of bone elasticity determination was realized at D21, D42 and D72. The average of speed ultrasound differed between groups at D21, D42 and D72, and the animals from EG had lower bone mineral density after applications of ESWT. There was also difference in the analysis of bone mass (Z-Score) between the groups at D21 and D42, which animals from EG showed a significant decrease in bone mass. The risk of fracture was higher in animals from experimental group at D21. It was concluded that ESWT is able to promote change in bone mineral density.
Resumo:
Recently, classical elasticity theory for thin sheets was used to demonstrate the existence of a universal structural behavior describing the confinement of sheets inside cylindrical tubes. However, this kind of formalism was derived to describe macroscopic systems. A natural question is whether this behavior still holds at nanoscale. In this work, we have investigated through molecular dynamics simulations the structural behavior of graphene and boron nitride single layers confined into nanotubes. Our results show that the class of universality observed at macroscale is no longer observed at nanoscale. The origin of this discrepancy is addressed in terms of the relative importance of forces and energies at macro and nano scales. © 2012 Materials Research Society.
Resumo:
Cosmetic Dermatology is a growing subspecialty. High-quality basic science studies have been published; however, few double-blind, randomized controlled clinical trials, which are the major instrument for evidence-based medicine, have been conducted in this area. Clinical research is essential for the discovery of new knowledge, improvement of scientific basis, resolution of challenges, and good clinical practice. Some basic principles for a successful researcher include interest, availability, persistence, and honesty. It is essential to learn how to write a protocol research and to know the international and national regulatory rules. A complete clinical trial protocol should include question, background, objectives, methodology (design, variable description, sample size, randomization, inclusion and exclusion criteria, intervention, efficacy and safety measures, and statistical analysis), consent form, clinical research form, and references. Institutional ethical review board approval and financial support disclosure are necessary. Publication of positive or negative results should be an authors' commitment. © 2013 by Anais Brasileiros de Dermatologia.