127 resultados para Distribution network reconfiguration


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper describes the preliminary studies of University of Minho on the use of Electric Impedance/Resistance Tomography to assess masonry structures. The study is focused on the analysis of values of current and voltage resulting from the use of an electrical source with voltage and frequency values from a distribution network. The analysis is made from results obtained through computer simulations, using a three-dimensional model of the idealized masonry structures. A finite element program was used for the simulations. Three types of electrodes were used in simulations, and the analysis of the results led to significant conclusions. Later masonry specimens were built and a series of preliminary tests were carried out in the laboratory. The comparative analysis of simulated and experimental results allowed identifying the factors that have influence on the physical results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study was shown the historical uses of compressed air by humanity, the general scenario of its uses and the most important steps of a project to set up an industrial network of compressed air, from the selection of a suitable compressor to the design of a distribution network, discussing all the possibilities and their characteristics as well as the feasibility of them. A case study was conducted in a food company where was implemented an industrial compressed air network. Information was collected regarding the consumers points of compressed air, as well as the layout of the new facility, necessary for the development of the distribution system. Two methods were used, analytical and nomogram, which complemented each other to the definition of appropriated tubing, both financially and physically

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Distribution networks are formed by long lines that carry electricity substations to homes and industries. These lines have associated impedance and depending on operating conditions of the network these impedances may vary. This paper provides a detailed analysis of the effects observed in studies of voltage drop, short circuit and electrical losses, when considered the drivers sequence impedances used in primary distribution network at different temperatures. Therefore, it is initially presented a calculation methodology and details the factors that influence the final values. The methodology presented tackles in a practical way the main factors that directly or indirectly influence the values of the impedances as an emblematic example and will be properly dealt with throughout the paper is the effect of temperature on the values of the sequence impedances. More specifically is dealt with the case of XLPE cables protected, by having a higher maximum operating temperature than the operating temperature of the network. The effects observed in the power flow generated when considering the impedance values at both temperatures were analyzed. The impedance drivers tend to increase with increasing temperature. Thus the impedance of the conductor XLPE protected will tend to be greater for the maximum operating temperature for which the operating temperature of the network, resulting in greater voltage drop and higher electrical losses