186 resultados para Contaminação microbiana
Resumo:
The recuperation of areas used during the construction of the hydroelectric plant, especially in 'borrowed areas', is a difficult and long process since all vegetation and the fertile layer of soil were removed. Interventions in these degraded areas could accelerate the revegetation process. The objective of this research was to evaluate the association of arbuscular mycorrhizal fungi (AMF) in tree species, microbial activity (basal respiration) and fertility of 'cerrado' degraded areas. Soil from two areas, pasture soil and exposed subsoil, were utilized. Organic and mineral fertilization, and liming, were added to the pit for better seedlings' initial growth, where 50 mL of preserved cerrado soil was applied as inoculum of microorganisms. Seedlings of 11 tree species were planted: Anadenanthera falcata (Benth.) Speg ('angico-preto'), Acacia polyphylla D. C. ('monjoleiro'), Stryphnodendron adstringens (Mart.) Coville ('barbatimao'), Dimorphandra mollis Benth ('faveiro'), Hymenaea stigonocarpa Mart. ex Hayne ('jatoba-de-cerrado'), Dipteryx alata Vog. ('baru'), Machaerium acutifolium Vogel ('jacaranda-do-campo'), Schinus terebinthifolia Raddi ('aroeirapimenteira'), Magonia pubescens St. Hil. ('tingui'), Lafoensia pacari St. Hil. ('dedaleira') and Tabebuia aurea (Manso) Benth. & Hook ('ipe-amarelo'). Twelve months later, root samples were colleted at the depth of 0-0.10 m and used for evaluations. The subsoil, as compared to pasture soil, was poor in organic matter and presented less microbial activity. The highest mycorrhizal colonization was seen in the species Acacia polyphylla D. C. (monjoleiro), Magonia pubescens St. Hil. (tingui), Hymenaea stigonocarpa Mart. ex Hayne (jatoba-de-cerrado) and Schinus terebinthifolia Raddi (aroeira-pimenteira). These species could be indicated in revegetation projects in 'cerrado' degraded areas. Plants from both areas showed seedlings form high mycorrhizal colonization and low numbers of spores.
Resumo:
Microbial contamination of an enclosed area may come from outside or be generated within the area itself. In the study described here, bioaerosol levels in hospital air were quantified and related to those found in the air outside, taking into account some of the environmental variables that affect air quality, such as the number of occupants of a room and the type of ventilation. Airborne bacteria were collected for five minute by blowing air at 500 L min -1 in high speed jets on to the surface on plates culture in a single-stage bioaerosol impactor. The mean viable count of bacteria in the air outside in the hospital, São Paulo State, was 77 ± 4 CFU m -3, while in the air inside the hospital it was 302 ± 260 CFU m-3. The operating theatre was the only space sampled with a controlled environment and, after orthopedic surgery, it had the highest bioaerosol count recorded (867 ± 482 CFU m-3). In the enclosed environments, nine bacterial species were identified. Despite the difficulty in establishing precise numbers of bacteria in the bioaerosols in hospital environments, the values obtained demonstrate a need to instigate suitable programs to keep the microbial density low in these environments, and eliminate microorganisms presenting a significant risk to their occupants. It is also recommended that such programs include the monitoring of hospital air, with the aim of defining standards for acceptable numbers of bacteria in the bioaerosol.
Resumo:
The degraded soil shows, in general, poor biological activity, considering its physical characteristics, low fertility and organic matter, mainly due to removal or degradation of its superficial layer. The sewage sludge, due to its high content of easily decomposed organic matter can be an alternate source of organic residues and combined to its high content of the principal nutrients for the plants can be an important factor to promote biological activities in degraded soil. In order to study the actions of the sewage sludge in the recovery of a degraded Latosol, the carbon in the microbial biomass (C mic), the carbon released CO2 (C-CO2) and the relation between microbial and organic carbon (Cmic/Corg) were used as indicators of the effects. To do so, two doses (30 and 60 Mg ha-1) of sewer slime applied in topdressing and incorporated together with a mineral fertilizer treatment, using the eucalyptus as a test crop. A completely randomized design with 4 treatments and 4 repetitions was used. The sewage sludge promoted increase of liberated C-CO2 and the C mic, which constitute the adequate quality indicators for monitoring the soil recovery.
Resumo:
The definition of models and base parameters for application of investigation tools in environment with high complexity are a basic premise to any sciences. The geophysics is a science with solid theoretical base and applications in diversified areas of the sciences geological, astronomical, meteorological, among many others. Its application in environmental studies is relatively recent and needs further research. To understand the behavior of resident contaminants in a dynamic and complex environment as the geological, it requests studies in scale laboratorial, under control of factors seasonality variable. This work simulates a leak of gasoline in soil, under conditions and in laboratory scale, with the objective of monitoring the temporary behavior of the hydrocarbon under the optics of variation of the parameter physical electric resistivity. The results indicate increase of the resistivity in recent periods the contamination, followed for stability in the values and finally fall and return tendency to the natural conditions.
Resumo:
Objective: The aim of this study was to assess the bond strength of adhesive systems to dentin contaminated by temporary cements with or without eugenol. Method: Flat dentin surfaces were obtained from twenty-four human third molars. With exception of the control group (n=8), the surfaces were covered with Interim Restorative Material (Caulk Dentsplay, Milford, DE, USA) or Cavit (3M ESPE, St. Paul, MN, USA) and kept in an oven at 37°C for seven days. After removing the cements, the adhesive systems Adper Single Bond (3M ESPE, St. Paul, MN, USA) or Clearfil SE Bond (Kuraray Co. Ltd., Osaka, Japan) were applied in accordance with the manufacturers' recommendations, and then the crowns were constructed in of resin composite. The teeth were sectioned into specimens with a cross-sectional bond area of 0.81mm2, which were submitted to microtensile testing in a mechanical test machine at an actuator speed of 0.5mm/min. The data were analyzed by t- and ANOVA tests, complemented by Tukey tests (α=0.05). Results: For Adper Single Bond (3M ESPE, St. Paul, MN, USA), bond strength did not differ statistically (p>0.05) for all the experimental conditions. For Clearfil SE Bond (Kuraray Co. Ltd., Osaka, Japan), only the Interim Restorative Material (Caulk Dentsplay, Milford, DE, USA) Group showed significantly lower bond strength (30.1 ± 13.8 MPa) in comparison with the other groups; control (38.9 ± 13.5 MPa) and Cavit (3M ESPE, St. Paul, MN, USA) (42.1 ± 11.0 MPa), which showed no significant difference between them. Conclusion: It was concluded that the previous covering of dentin with temporary cement containing eugenol had a deleterious effect on the adhesive performance of the self-etching system only.
Resumo:
This work aimed to determine ruminal parameters of dry mater (DM), neutral detergent fiber (NDF) and protein synthesis in the rumen of animals fed diets based on sorghum with different tannin levels. In situ degradation was evaluated by rumen incubation of level 1 (L1) and level 2 (L2) sorghum silages during 0, 6, 24, 48 and 96 hours. A duplicated 4 × 4 Latin Square was used. Potential degradability (PD) of DM was similar among silages, whereas the effective degradability (ED) decreased when the diets were supplemented with concentrate. Microbial nitrogen flux and microbial synthesis efficiency were not affected by roughage source. The synthesis efficiency, expressed in organic matter and crude protein digested in rumen, was higher in L1 tannin diets supplemented with concentrate. There was not relationship between the presence of tannins and the parameters of ruminal degradation.
Resumo:
Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.
Resumo:
Although the quality of sea recreational waters is already monitored by programs implanted in some Brazilian states, including the State São Paulo, little attention has been given to beach sands, which have been disregarded from the point of view of public health. However, this panorama is changing in recent years due to an increasing number of cases of mycoses and bacterial infections affecting people who frequent beaches and use sands as recreation places. This has caused greater concerns with the contamination of this environment, also measurable by the increase of the number of scientific works on sediments and recreational beach sands microbiota. Currently one knows that in general these sediments contain more microorganisms than the water and are therefore potential sources of contamination of human beings by pathogenic microorganisms. The results of works carried through in some countries are worrying, and have demonstrated the necessity of establishing standards and limits so that monitoring programs of the microbiological quality of beach sands are implanted. Such concern is especially high in Brazil, a country of a tropical climate where thousands of beaches, used for recreation, extend for almost eight thousand kilometers of the coast. In the context of Baixada Santista, studies carried through have shown that in certain situations beach sands can contain more microorganisms than waters and may be a risk to the health of users.
Resumo:
Water is the raw material used most in the production of diverse pharmaceutical forms and, being a constituent of the formulation itself, is subject to a number of physico-chemical and microbiological specifications. In addition, it is indispensable for laboratory tests and the cleaning of equipment and apparatus. The aim of this study was to ascertain the degree of physicochemical and microbiological contamination of purified water used in compounding pharmacies in the city of São José do Rio Preto, SP, Brazil. Samples were taken as recommended in the USP Pharmacopeia, with careful aseptic technique, and sent immediately the to quality control laboratory. Physicochemical properties were analyzed, including appearance, pH, conductivity, residue after evaporation, ammonia, calcium, chloride, heavy metals, sulfate and oxidizable substances, and microbiological tests were performed: total aerobic microbial count and detection of total and thermotolerant coliforms and Pseudomonas aeruginosa. Results showed that some parameters did not conform to the standards, especially pH, conductivity, inorganic impurities, oxidizable substances and microbiological test data, in 10%, 17%, 10%, 14% and 20% of the analyzed samples, respectively, This points to the need for greater care in the production and/or storage of purified water in these pharmaceutical establishments.
Resumo:
The objective of this paper was to review data on residues of medical products in aquatic environments and at wastewater treatment plants. Secondarily the paper presents a discussion about the need for a good management of drugs residues and effluents generated by this sector. Bringing the evidences of environmental possible damages reported by ecotoxicity data on the effects of fluoxetine to Vibrio fischeri and H. azteca, aquatic organisms daily exposed to environmental contaminants. From the results we observed that 0.3 mg.l-1 of fluoxetine hidrochloride induced lethality to H. azteca and 30 mg.l-1 reduced the luminescence of Vibrio fischeri. This assay evidenced higher toxicity when we used the generic product.
Resumo:
Improper use of pesticides can lead to significant environmental impacts such as, contamination of environmental compartments, being the aquatic compartments the most vulnerable. In this context, the spatialization of pesticides concentrations estimative in groundwater provides important insights for decision making in managing and monitoring pesticides use. This study aimed to spatialize estimatives of groundwater contamination by Tebuthiuron, from different irrigation depths in the Rio Pardo basin, Pardinho-SP, Brazil. The simulations were performed using the ARAquá computer system, considering 0mm, 200 mm and 400 mm annual irrigation depths. Geostatistical techniques were used to obtain the spatial distribution of the simulated estimative. Tebuthiuron maps estimating concentration in groundwater were obtained by Kriging interpolation method, and indicated the areas with high potential for groundwater contamination. Considering all the simulations, it was concluded that there was no risk of groundwater contamination by Tebuthiuron in the study area.
Resumo:
Several factors have contributed to the increase the world production of urban solid waste, resulting in difficulties to the correct management and the final environmentally appropriate disposal, in addition to causing serious socio-economic, environmental, and public health troubles. The soil and groundwater contamination by leachate in waste disposal sites is almost always present, leveraging the emergence and/or adaptation of methodologies for environmental assessment of these areas. The geophysical methods, especially the electrical resistivity method, are fast, reliable and low-cost alternative for this purpose. This paper reports the methodology adopted for the temporal monitoring of the plume of contamination of controlled landfill in the municipality of Rio Claro (SP). Electrical resistivity data were obtained in 1999 and 2008, by the resistivity method, using the techniques of vertical electrical sounding and electrical profile. In both years, similar tests were carried out in the same locations within the disposal area. The results indicated that the plume of contamination has resistivity values less than or equal to 50 ohm.m and moves guided by 2 flows: the main, to the southeast, and the secondary, to the west. Relatively to the first series of tests in 1999, the plume of contamination was higher and deeper in 2008, contrary to what was expected for a landfill deactivated for at least 10 years.
Resumo:
Agriculture is an activity in which there is the possibility of using lower quality water and reuse appears as an alternative for irrigation. However, the negative environmental effects of reuse must be understood. The objective of the present work was to verify the potential of groundwater contamination by nitrogen duo to drip irrigation with effluent from domestic wastewater treatment. Three crop cycles of lettuce cv. Raider were conducted, the first between October and November 2009, the second in April and May 2010 and the third one in June and July 2010. The use of effluents was compared with potable water at accumulated water depths of 98.8 mm for the first, 98.4 mm for the second and 119 mm for the third cycle. Soil percolate concentrations of nitrate, nitrite and ammonia were studied at 0.25 m and 0.50 m depths in a completely randomized design. Percolate concentrations of nitrite and ammonia in soil irrigated with effluents showed no groundwater contamination risk. Nitrate however, caused concern, albeit with similar concentrations for both effluent and potable water.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)