258 resultados para Coliforms
Resumo:
The microbiological quality of various fresh waters in the Araraquara region, state of São Paulo, Brazil was investigated. Ninety-nine water samples were taken from rivers, reservoirs, artesian and non-artesian wells, springs and tap waters, and these waters were analysed using: plate counts of heterotrophic microorganisms (per 1 ml); Most Probable Number (MPN) of fecal coliforms and E. coli (per 100 ml); tests for presence of Salmonella, Shigella, Yersinia, the E. coli pathogens of classes EPEC, ETEC and EIEC and Mycobacterium, Shigella, Yersinia and enteroinvasive E. coli (EIEC) were not isolated. The other types of microorganisms were isolated in varying proportions. We conclude that the waters investigated represent a potential microbiological health risk.
Resumo:
The main water source of the Rio Claro municipal district (DAAE) was analysed for determining the level of organic contamination. Temperature, pH, light penetration, conductivity, dissolved oxygen, total dissolved phosphate, ortophosphate, ammonia, heterotrofic bacteria, total coliforms, fecal coliforms, total yeasts and fermentative yeasts were analysed during one year with samples being collected on a monthly basis. Bathing quality of the water from sites 1, 2 and 3 were classified, respectively, as Satisfactory, Very Good and Improper based on fecal coliform counts. Total yeast counts were appropriate as a complement for the appraisal of fresh water contamination by coliform counts. Seventeen yeast species belonging to genera Candida, Cryptococcus, Kloeckera, Pichia and Rhodotorula were found but none of them could be correlated with a level of contamination. Candida famata, C. robusta-like and C. colliculosa were isolated at all of the sites and between the five species found only at the more polluted site, Rhodotorula mucilaginosa was prevalent.
Resumo:
The goal of this study was to evaluate the process of salting and dry salting of fillets in pacu (P. mesopotamicus), from cultivation in cages. Fillet with skin were salted at a rate of 40% of salt in relation of the initial weight, for a period of 10 days. After processing, were evaluated for microbiological and centesimal composition of fillets subjected to salting and determining the concentration of sodium chloride (NaCl) and calculation of income. The centesimal composition were evaluated the protein, ether extract, moisture and ash of the raw material fresh and processed products by salting. The microbiological analysis included the determination of coliforms at 45 degrees C, Salmonella and Staphylococcus coagulase positive. The pacus subjected to umided and dry salting were within quality control standards established by the legislation. The content of umided, protein, lipids and chlorides showed differences (p< 0.05) between the processes of salt. However both forms can be used for the development of technological processes of low investment by encouraging new options for fish consumption.
Resumo:
Prototypes A (bidin + broken stones + gravel stones + gross sand + activated coal) and B (bidin + broken stones + gravel stones + gross sand) under hydraulic charge of 35 cm presented outlets that, when extrapolated for larger filters, are sufficient to supply small and medium irrigation projects for vegetables and fruits. (bidin = Rhodia polyester for drainage). Under a charge of 35 cm, filtrate of both prototypes presented a reduction of fecal coliforms, being this reduction higher for A prototypes, but, even in this case, the coliform quantities were superior to the legal limit. Under a decrease of the biochemical oxygen demand an increase of the available oxygen rate; pH and hardness did not present significant changes.
Resumo:
Sixty small farms of Botucatu County, S. Paulo, Brazil, given over to cattle breeding were studied. These farms account for 15% of the total of 402 farms that exist in the county. The sample was drawn by simple probabilistic technique. There were found to be one hundred and thirteen drinking places located on the farms. Samples of water were taken from these drinking places and examined for bacteria of the genus Salmonella, for the determination of Most Probable Number (MNP) of fecal coliform bacteria as well as determination of the water's pH. Water temperature was measured before collection. Samples from 15 drinking places (13.3%) were positive for Salmonella. The drinking places belonged to 12 of the sixty farms studied (20%). The following serotypes were identified: S. dublin, S. newport, S. madelia, S. IV 43:g,z57:-, S. saphra, S. glostrup, S. IV ochsenzool; S. I9,12:i:- and two new serotypes S. IV 41:z52:- and S. IV 50:d:-. Of the 113 samples studied 14 (12.4%) presented MPN/100ml of fecal coliforms above 4,000. There was no relationship between MPN/100ml of fecal coliforms above 4,000 and positivity for Salmonella. Highest positivity both for Salmonella and MPN/100mL of fecal coliforms over 4,000 occurred at temperatures above 18 degrees C. As regards pH, in both situations the highest positivity occurred between 6.0 and 7.0.
Resumo:
Aiming to know the influence of the pluviometric precipitation over the physical chemical and bacteriological characteristics of the water coming from three sources of public supply, and to verify the probable origin of faecal contamination, tests of total coliforms, faecal coliforms, faecal streptococci and mesophilic microorganisms, as well as the determination of pH, temperature and turbidity of 156 water samples were done. The samples were taken from a stream, a drain and an artesian well, located in the city of Jaboticabal, SP, Brazil. The results obtained showed that the occurrence of pluviometric precipitation determined a significant increase of the number of total coliforms in the water samples from the stream. The use of the ratio CF/EF, indicate the probable origin of the faecal contamination only in the samples of the water coming from the stream, which were defined as being of human origin. In relation to the physical-chemical composition it was noticed that the influence of the pluviometric precipitation over the turbidity appeared to be higher and significant in the samples of water of the stream.
Uso de macroalgas para avaliação da Poluição orgânica no Rio Preto, noroeste do estado de São Paulo.
Resumo:
The Preto River, located in the northwest of São Paulo State, receives a total wastewater load of 15.150 kg DBO day-1, from which 13.685 kg DBO day-1 (90.5%) corresponds to domestic sewage, and the city of São José do Rio Preto contributes with 12.400 kg DBO day-1 (90% of domestic sewage). During the period from August 1990 through January 1991, monthly sampling was carried out to evaluate the use of macroalgae as bioindicator of organic pollution. Five sampling sites were established along the main river and the following variables were analised: temperature, conductance, turbidity, dissolved oxygen, BOD, COD, total and fecal coliforms, and composition and abundance of macroalgal communities. Data were submitted to analysis of variance, correlation coefficient, cluster analysis (four different approaches) and converted to biological indices (species deficit, relative pollution, saprobity, diversity and uniformity indices). A wide range in water quality was found (particularly for conductance, oxygen, BOD and COD) among the sampling sites, which were classified into three groups (polluted, moderately polluted and unpolluted/weakly polluted). As regards the occurrence and abundance of macroalgae the Rhodophyta were found only in unpolluted or weakly polluted sites, whereas Cyanophyta occurred mostly under high pollution load; the Chlorophyta species were observed under a wide range of conditions. Among the biological indices, saprobity was the most sensitive and correlated to all water variables and the other indices. Cluster analyses showed that the composition of macroalgal communities was consistent with the levels of organic pollution in the Preto River.
Resumo:
Milk can be an important spreading vehicle of pathogenic agents mainly for young children who are an important group of milk consumers. 135 milk samples (77 of raw milk and 58 of pasteurized milk) were analysed in order to verify the number of heterotrophic bacteria, of Staphylococcus aureus and of total coliforms, as well as to determine presence of Salmonella, Shigella, enteropathogenic Escherichia coli (EPEC) and enteroinvasive Escherichia coli (EIEC). The results were negative for Salmonella, Shigella and EIEC. EPEC serotypes 0:28, 0:111 and 0:55 were isolated in 4 of raw milk samples. The heterotrophic bacteria was found in counts over 30.000 UFC/mL in 91%, 25% and 68,75% respectively of raw milk, milk grade B and grade C. Counts over 30.000 coliforms/mL were found in 70,13%, 6,25% and 6,24% of the raw milk, B and C, respectively. 32,40% of the raw milk had counts of S. aureus over 3.000 UFC/mL.
Resumo:
The number and the main groups of microorganisms present in samples of different nonalcoholic carbonated beverages (lemon, orange and guaraná soft drinks) obtained from a small factory were analyzed. The samples were obtained at the end of the processing line. They were then divided into two lots: one was sent to immediate analysis, the other was stored at environmental temperature for 90 d thereafter it was submitted to the same analysis. Aliquots of 1 mL were drawn from the various samples and the corresponding decimal dilutions were prepared. They were then grown in culture media and counts of mesophilic aerobic bacteria, molds and yeasts, acid-producing bacteria, total and fecal coliforms were taken. It was observed that, of all the analyzed samples, at time 0 or after storage sample C (orange) was the best, since it conformed to the microbiological standards established by legislation. The guaraná type could also be consumed on day zero; the lemon type was inadequate for consumption of all the analyzed samples, the orange type was the only one that could be consumed within 3 months of storage.
Resumo:
The project is being conducted in the town of Analândia, São Paulo, Brazil. The constructed wetlands system for water supply consists of a channel with floating aquatic macrophytes, HDS system (Water Decontamination with Soil - Patent PI 850.3030), chlorinating system, filtering system and distribution. The project objectives include investigating the process variables to further optimize design and operation factors, evaluating the relation of nutrients and plants development, biomass production, shoot development, nutrient cycling and total and fecal coliforms removal, comparing the treatment efficiency among the seasons of the year; and moreover to compare the average values obtained between February and June 1998 (Salati et al., 1998) with the average obtained for the same parameters between March and June 2000. Studies have been developed in order to verify during one year the drinking quality of the water for the following parameters: turbidity, color, pH, dissolved oxygen, total of dissolved solids, COD, chloride, among others, according to the Ministry of Health's Regulation 36. This system of water supply projected to treat 15 L s-1 has been in continuous operation for 2 years, it was implemented with support of the National Environment Fund (FNMA), administered by the Center of Environmental Studies (CEA-UNESP), while the technical supervision and design were performed by the Institute of Applied Ecology. The actual research project is being supported by FAPESP.
Resumo:
Ice used for human consumption or to refrigerate foods can be contaminated with pathogenic microorganisms and may become a vehicle for human infection. To evaluate the microbiological content of commercial ice and ice used to refrigerate fish and seafood, 60 ice samples collected at six different retail points in the city of Araraquara, SP, Brazil, were studied. The following parameters were determined: total plate counts (37° C and 4° C), most probable number (MPN) for total coliforms, fecal coliforms and Escherichia coli, presence of Salmonella spp., Shigella spp., Yersinia spp., E. coli, Vibrio cholerae and Aeromonas spp.. Results suggested poor hygienic conditions of ice production due to the presence of indicator micro-organisms. Fifty strains of E. coli of different serotypes, as well as one Y. enterocolitica biotype 1, serogroup 0:5, 27 and phage type Xz (Ye 1/05,27/Xz) and one Salmonella Enteritidis phage type 1 (PT1) were isolated. Aeromonas spp., Shigella spp. and V. cholerae were not detected. The presence of high numbers of coliforms, heterotrophic indicator micro-organisms and pathogenic strains suggested that commercial ice and ice used to refrigerate fish and seafood may rep resent a potential hazard to the consumer in our community. © 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
The effects of metal bioleaching on nutrient solubilization, especially nitrogen and phosphorous, from anaerobically-digested sewage sludge were investigated in this work. The assessment of the sanitary quality of the anaerobic sludge after bioleaching was also carried out by enumerating indicator (total coliforms, fecal coliforms, and fecal streptococci) and total heterotrophic bacteria. The experiments of bioleaching were performed using indigenous sulphur-oxidizing bacteria (Thiobacillus spp.) as inoculum and samples of anaerobically-digested sludge. Nitrogen and phosphorous solubilization from sewage sludge was assessed by measuring, respectively, the concentration of Total Kjeldahl Nitrogen, ammonia, nitrate/nitrite, and soluble and total phosphorous before and after the bioleaching assays. At the end of the experiment, after 4 days of incubation (final pH of 1.4), the following metal solubilization yields were obtained: zinc, 91%; nickel, 87%; copper, 79%; lead, 52%; and chromium, 42%. As a result of sludge acidification, the viable counts of selected indicator bacteria were decreased to below the detection limit (4 × 103 cfu 100 ml-1), followed by an increase in the mineral fraction of nitrogen (from 6 to 10%) and in the soluble fraction of phosphorous (from 15 to 30%). Although some loss of sludge nutrients can occur during solid-liquid separation following bioleaching, its beneficial effects as metal removal and reduction of pathogenic bacteria are sufficient to consider the potential of this treatment before sludge disposal onto agricultural fields.
Resumo:
Objective. To assess the potential for contamination of wastewaters from pig farming. Methods. Wastewaters from pig farming were stored in a tank. After 0, 30, 60, 90, and 120 days of hydraulic retention, they were added to lysimeters filled with argillaceous, sandy, or medium soil. Finally, these lysimeters were submitted to simulations of either a rainy season or a dry season. The number of colony-forming units (CFUs) of total coliforms, fecal coliforms, and fecal streptococci was measured in the effluents of the storage tank (for the various periods of hydraulic retention), in the percolate from the lysimeters, and in the three types of soil. The microbiological analyses were carried out using the membrane filter technique. The pH analyses were done potentiometrically. Results. For the three microorganisms, the largest decrease in bacterial counts in the storage tanks occurred with 90 or 120 days of retention. There was a marked decrease in the bacterial count in the percolates of the three soils. For the three soil types the greatest reduction in bacterial counts was found in medium soil, due to its acidity (pH < 7.0). Hydraulic retention was not sufficient to ensure the sanitary adequacy of the wastewaters and their use for irrigation, given that fecal coliform values were above 1 000 CFU per 100 mL. Therefore, adding the residues to the soil was considered a second stage of treatment. Conclusions. The retention of wastewaters followed by adding them to soil was effective in minimizing the contaminating effect of pig farming residues. The storage time for wastewaters from pig farming could be decreased from 120 to 90 days.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The use of masks is generally accepted as a means of protecting the individual against microbial pathogens that might be inhaled in unhealthy environments. The objective of this study was to evaluate the efficiency of disposable surgical masks sold in Brazil, against coliforms in aerosols emitted by the aerators of a sanitary sewage treatment station. The filtration efficiency varied from 50.9% to 99.9% for 6 masks from different sources.