295 resultados para Cleaning.
Resumo:
The aim of this study was to evaluate the persistence of methacrylate-based cement residues on the dentin, after dentin surface cleaning with ethanol or acetone, with or without previous application of a dentin adhesive. Forty bovine crown fragments were obtained and the dentin surface was washed with 1.0 mL of 2.5% sodium hypochlorite (NaOCl), followed by 0.1 mL of 17% ethylenediaminetetraacetic acid application for 3 min, and final irrigation with 2.5% NaOCl. The specimens were air dried and resin-based cement was rubbed onto the dentine surface with a microbrush applicator. In 20 specimens, previously to cement, a dentin adhesive was applied in all surfaces. After 15 min, the surface was scrubbed with a cotton pellet and moistened with ethanol or acetone, compounding the following groups: G199.5% ethanol and G2acetone, without previous use of dentin adhesive; G399.5% ethanol and G4acetone, with previous use of dentin adhesive. The dentin surface was scrubbed until the cement residues could not be visually detected. Sections were then processed for scanning electron microscopy and evaluated at 500x magnification and scores were attributed to each image according to the area covered by residual sealer, and data were subjected to KruskalWallis at 5% significance. The lower residue presence was observed in G3 (P = 0.005). All surface presented cement residues when acetone was used as cleaning solution (P = 0.0005). The cleaning solutions were unable to completely remove the cement residues from both surfaces. The ethanol used after previous application of the dentin adhesive promoted the lower presence of residues.
Resumo:
The aim of this study was to evaluate the persistence of resin cement residues after dentin surface cleaning with different alcohol-based solutions or an essential oil (eucalyptol). Forty bovine teeth were sectioned in order to expose pulp chamber dentin to be washed with 1.0 mL of 2.5% sodium hypochlorite (NaOCl), followed by 0.1 mL of 17% EDTA application for 3 min, and final irrigation with 2.5% NaOCl. The specimens were air dried and resin-based cement was rubbed onto the dentine surface with a microbrush applicator. After 15 min, the surface was scrubbed with a cotton pellet and moistened with different dentin cleaning solutions, compounding the following groups: G195% ethanol, G270% ethanol, G370% isopropyl alcohol, or G4eucalyptol. The dentin was scrubbed until the cement residues could not be visually detected. Sections were then processed for SEM and evaluated at x 500 magnification. Scores were attributed to each image according to the area covered by residual sealer, and data were subjected to KruskalWallis at 5% significance. Eucalyptol promoted the most adequate dentin cleaning, although no statistical difference was detected amongst the groups (P > 0.05), except between the eucalyptol and 70% ethanol groups (P < 0.05). All the evaluated dentin cleaning solutions were unable to completely remove the cement residues from the dentin surface. Microsc. Res. Tech., 2012. (C) 2012 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Lipases from oilseeds have a great potential for commercial exploration as industrial enzymes. Lipases are used mixed with surfactants in cleaning and other formulated products, and accordingly, both components must be compatible with each other. This work presents the results of the effects of anionic, cationic and nonionic surfactants, polyethylene glycol and urea on the activity and stability of a lipase extracted of oilseeds from Pachira aquatica. The enzyme was purified and the spectrophotometric assays were done using p-nitrophenyl acetate (p-NPA) as substrate pH 7.5 and 25 degrees C. The activity was significantly enhanced by the cationic surfactant CTAB. Bile salts increased the lipase activity in the tested concentration range, whereas anionic and nonionic surfactants showed an inhibitory effect. Aqueous solutions of PEG activated the lipase and maximum activation (161%) occurred in PEG 12,000. This effect on lipase that can be due to exposition of some hydrophobic residues located in the vicinity of the active site or aggregation.
Resumo:
Purpose: The aim of this study was to assess the use of oral piercings and their possible associated complications among students aged 14 to 18 years.Materials and Methods: A total of 927 students from private and state schools were invited to participate in this study. The participants were subjected to clinical examination, and a questionnaire was provided for collecting the following data: gender, piercing location, oral complications or alterations, and cleaning frequency.Results: Among the students who were analysed, 33 had oral piercings (3.6%); 69.70% were from state schools and 30.30% were from private schools. There was a slight predominance of males (54.55%) compared with females (45.45%). The tongue was the most common location for piercing (66.6%). The complications and alterations associated with the use of piercing were observed in 74.3% of the cases.Conclusions: In the population that was studied, oral piercing was observed in a small percentage of teenage students (3.6%) and there were local complications associated with its use.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: the ability of the laser irradiation to promote the cleaning and disinfection of the radicular canal system has become this type of treatment in a viable and real alternative in endodontics. The purpose of this study was to evaluate the apical marginal sealing of root canal fillings after the irradiation with the laser of Nd:YAG or of Er:YAG. Materials and Methods: Forty-two human, extracted single-rooted teeth had their crowns sectioned and the root canals prepared with a no. 70 K-file. Then, they were dried and divided into three groups according to canal wall treatment: group 1: the canals were filled with EDTA for 3 min, followed by irrigation with 1% sodium hypochlorite solution; group 2: the canal walls were irradiated with Nd:YAG laser; and group 3: the canal walls were irradiated with Er:YAG laser. Afterwards, the root canals were obturated by the lateral condensation technique. The roots were externally waterproof, except in the apical foramen and immerged in 2% methylene blue aqueous solution during 48 hours. Results: the results showed that the largest infiltrations happened in the group 3-Er:YAG (7.3 mm), proceeded by the group 1-EDTA (1.6 mm) and by the group 2-Nd:YAG (0.6 mm). The group Er:YAG differed statistically of the others (p < 0.05). Conclusion: It was concluded that the Er:YAG laser intracanal irradiation previously to the root canal filling must be used with caution until future research is define the best parameters for it's use.
Resumo:
The aim of this study was to evaluate the influence of silica coating and 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-based primer applications upon the bonding durability of a MDP-based resin cement to a yttrium stabilized tetragonal zirconia (Y-TZP) ceramic. Ninety-six Y-TZP tabs were embedded in an acrylic resin (free surface for adhesion: 5 x 5 mm(2)), ground finished and randomly divided into four groups (N = 24) according to the ceramic surface conditioning: (1) cleaning with isopropanol (ALC); (2) ALC + phosphoric acid etching + MDP-based primer application (MDP-primer); (3) silica coating + 3-methacryloyloxypropyl trimethoxysilane (MPS)-based coupling agent application (SiO(2) + MPS-Sil); and (4) SiO(2) + MDP-primer. The MDP-based resin cement was applied on the treated surface using a cylindrical mold (diameter=3 mm). Half of the specimens from each surface conditioning were stored in distilled water (37 C, 24 h) before testing. Another half of the specimens were stored (90 days) and thermo-cycled (12,000x) during this period (90d/TC) before testing. A shear bond strength (SBS) test was performed at a crosshead speed of 0.5 mm/min. Two factors composed the experimental design: ceramic conditioning strategy (in four levels) and storage condition (in two levels), totaling eight groups. After 90d/TC (Tukey; p < 0.05), SiO(2) + MDP-primer (24.40 MPa) promoted the highest SBS. The ALC and MDP-primer groups debonded spontaneously during 90d/TC. Bonding values were higher and more stable in the SiO2 groups. The use of MDP-primer after silica coating increased the bond strength. (C) 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part 8: Appl Biomater 95B: 69-74, 2010.
Resumo:
Purpose: This study compared five types of chemical catalyzing agents added to 35% hydrogen peroxide gel, with regard to their capacity of intensifying in-office dental bleaching results.Methods: One-hundred and twenty bovine incisors were used, of which the crowns and roots were cut in the incisor-apical direction, to acquire the dimensions of a human central incisor. The specimens were sectioned in the mesiodistal direction by means of two longitudinal cuts, the lingual halves being discarded. The vestibular halves received prophylaxis with a bicarbonate jet, ultrasound cleaning and acid etching on the dentinal portion. Next, the specimens were stored in receptacles containing a 25% instant coffee solution for two weeks. After the darkening period, initial measurement of the shade obtained was taken with the Easy Shade appliance, which allowed it to be quantified by the CIELab* method. The samples were divided into six groups, corresponding to the chemical activator used: a) none (CON); b) ferric chloride (CF); c) ferrous sulphate (SF); d) manganese gluconate (GM); e) manganese chloride (CM); f) mulberry root extract (RA). Each group received three 10-minute applications of the gels containing the respective activating agents. Next, a new shade measurement was made.Results: The Analysis of Variance and Tukey tests (alpha=5%) showed statistically significant differences for the shade perception values (p=0.002). Groups GM, CM and RA showed significantly higher means than the control group.Conclusion: The presence of some chemical activators is capable of resulting in a significant increase in tooth shade variation.
Resumo:
We search for planar deviations of statistical isotropy in the Wilkinson Microwave Anisotropy Probe (WMAP) data by applying a recently introduced angular-planar statistics both to full-sky and to masked temperature maps, including in our analysis the effect of the residual foreground contamination and systematics in the foreground removing process as sources of error. We confirm earlier findings that full-sky maps exhibit anomalies at the planar (l) and angular (l) scales (l; l) = (2; 5); (4; 7); and (6; 8), which seem to be due to unremoved foregrounds since this features are present in the full-sky map but not in the masked maps. on the other hand, our test detects slightly anomalous results at the scales (l; l) = (10; 8) and (2; 9) in the masked maps but not in the full-sky one, indicating that the foreground cleaning procedure (used to generate the full-sky map) could not only be creating false anomalies but also hiding existing ones. We also find a significant trace of an anomaly in the full-sky map at the scale (l; l) = (10; 5), which is still present when we consider galactic cuts of 18.3% and 28.4%. As regards the quadrupole (l = 2), we find a coherent over-modulation over the whole celestial sphere, for all full-sky and cut-sky maps. Overall, our results seem to indicate that current CMB maps derived from WMAP data do not show significant signs of anisotropies, as measured by our angular-planar estimator. However, we have detected a curious coherence of planar modulations at angular scales of the order of the galaxy's plane, which may be an indication of residual contaminations in the full-and cut-sky maps.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O processo pirometalúrgico convencional para a produção de chumbo metálico é comparado com dois novos processos ambientalmente não agressivos: o eletrohidrometalúrgico e fusão alcalina. O processo eletrohidrometalúrgico consiste em reduzir o tamanho das partículas dos compostos de chumbo e lixiviar os mesmos com uma solução ácida de fluoborato férrico. Neste ponto, o chumbo é dissolvido com os íons férricos sendo reduzidos a íons ferrosos. A solução resultante da lixiviação é bombeada para os compartimentos catódicos de uma célula eletrolítica de diafragma nos quais o chumbo metálico é depositado em catodos de aço inoxidável numa forma compacta e pura. A solução que é empobrecida em íons Pb2+ é então enviada aos compartimentos anódicos da mesma célula onde, nas superfícies de anodos ocorre a oxidação dos íons ferrosos a férricos, que retornam ao estágio de lixiviação. O processo de fusão alcalina consiste em se juntar soda cáustica fundida, enxofre e compostos de chumbo num reator a uma temperatura entre 600 °C e 700 °C. Como um resultado chumbo metálico é obtido juntamente com sais fundidos de sódio, sulfetos metálicos e borra. O fundido é processado, resultando em borra, sulfetos metálicos, soda cáustica e enxofre. Estes dois últimos retornam para o reator. Ambos os processos permitem a recuperação de metais como antimônio, estanho, enxofre e prata, que em processo convencional são perdidos na escória. Esses novos processos são ambientalmente corretos sem poluições severas de Pb e SO2. O chumbo metálico obtido é mais puro que aquele do processo convencional.
Resumo:
Com a finalidade de quantificar o desempenho dos sistemas de debulhamento e limpeza da colhedora Penha CLM-350,, estudou-se as perdas percentuais era grão de milho, ocorridos na saída de palhas, bem como a porcentagem de impurezas, presente no milho ensacado. Tomando-se como 100% os grãos de milho colhidos pelo sistema espigador, determinou-se o valor percentual perdido pelos sistemas de debulhamento e limpeza, bem como a porcentagem de impurezas presente nos grãos de milho ensacado, nos diversos tratamentos estudados. O teor médio de umidade foi de 15,78% (b.u.). Os tratamentos correspondentes ao sistema de debulhamento e limpeza são as velocidades periféricas do debulhador ou as rotações do aspirador em faces da configuração geométrica da máquina. Os resultados obtidos foram estudados através da análise de variância, empregando-se os testes F, aos níveis de 1% e 5% de probabilidade e o teste Tukey, para a comparação estatística entre as médias. A análise estatística para verificar a influência da rotação do aspirador, era relação a porcentagem de grãos de milho perdidos na saída de palhas, mostrou diferenças altamente significativas, podendo-se admitir uma relação direta entre os dois parâmetros nas condições do ensaio. Com relação a rotação do aspirador e a porcentagem de impurezas, presentes nos grãos de milho ensacados, os testes das médias revelaram significância entre os tratamento D (1241,7 rpm) e E (820 rpm) sendo que este último apresentou a maior média. Uma análise mais acurada dos resultados sugere que a porcentagem de impurezas, estaria mais na dependência das relações de fluxo através da colhedora, do que propriamente do regime do aspirador.