187 resultados para Anomalias congênitas
Resumo:
This paper presents the results from lineal trend surface analysis technique application. The purpose was to detect positive and negative anomalies in the rain measure distribution obtained by the meteorological radar Doppler, band S, located in Bauru, during the period of 21 of October/2004 to 29 of April/2005 in the areas of Assis and Piracicaba. Using three Z-R radar relations for rain quantification was chosen the specific equation Z = 32R1,65, as the best one. The results showed that the applied methodology was able to indicate the space distribution of the rain accumulated, identifying and locating the regions where there was rainy excess and rainy lack during each analyzed period. Such results indicate areas with larger pluvial impact and consequently more favorable for environmental damages.
Resumo:
This is an exploratory and descriptive study that was jointly carried out by Nursing Care and Occupational Therapy as part of a Research Project that intended to prepare children for elective surgery at the University of São Paulo's Hospital de Reabilitação de Anomalias Craniofaciais. Objective: using toys as a therapeutic resource for relieving the child's real and unconscious tensions concerning hospitalization for surgical treatment at the HRAC - USP. Method: 44 children participated in the study. An observation form was used to collect data and it was applied at two separate times: the first time was the day before the surgery was to take place and the second on the day of the surgery just before the event. Twenty one variables were elaborated by the researchers to categorize behaviors regarding hospitalization. The resources used were: storytelling, dramatization and demonstration of nursing interventions with puppets dressed in surgical garb (gloves, surgical gown, mask and cap) with medical equipment commonly used in hospital. Results: of the 21 variables analyzed, 8 showed statistically significant differences on the McNemar Test (p<0.05). Conclusion: interactive play enables hospitalized children to interact in the hospital environment, so that they can express feelings and emotions and it contributes to humanized hospital assistance.
Resumo:
The Thermal Corridor of Uruguay River is located in the triple border of Argentine, Brazil and Uruguay, and shows an intense economic thermal tourism activity, mainly based on groundwaters from Guarani Aquifer System (GAS). Recent studies have pointed out the occurrence of high concentrations of arsenic (>10 μg/L) in GAS groundwater in this area. The complex geological and hydrogeological framework in the area is associated to the Paraná Basin geological evolution south of the Assuncion-Rio Grande Arch; it encompass paleozoic marine sequences and continental sequences permian/eotriassic to mesozoic in age, which are covered by basaltic lavas of Serra Geral Formation. Iron oxide coatings have been described in sandstones of Buena Vista and Sanga do Cabral formations, which underlie GAS units. Arsenic occurrence is associated to sodium bicarbonate groundwater with pH values over 8.0. Arsenic is released to groundwater by desorption from iron oxides/hydroxides, as result of the higher pH of these waters, indicating that arsenic is released from the units that underlie GAS units. Increase in chromium and uranium concentrations are also related to high pH groundwaters, thus indicating special care on using groundwater from this region.
Resumo:
Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time.
Resumo:
The geoelectrical methods have been widely used in research involving the evaluation and monitoring of areas with environmental risk. This paper presents the results of applying the Electrical Resistivity method by electrical profiling technique to investigate the fuel presence in soil and groundwater proceeding in station gas, located in an urban area Caçapava do Sul (RS), on soil in situ, from modification of Caçapava granite. The results suggest an association between low resistivity anomalies zone with potentially degraded from underground tanks worthless on the form of free phase, now represented as residual phase. The results of the model inversion are consistent with the standards expected for hydrocarbons present in the saturated zone. The electrical resistivity method proved to be an important tool for assessment and environmental monitoring in conjunction with direct methods of investigation.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biologia Geral e Aplicada - IBB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)