148 resultados para Américo Jacobina Lacombe
Resumo:
This work is intended to report on optical measurements in a parabolic quantum well with a two dimensional-three dimensional electron gas. Photoluminescence results show broad spectra which are related to emission involving several subbands on conduction band with the fundamental level of the valence band. This assumption is based on the behavior of the PL peak position and the full width at half maximum in the function of the incident power intensity. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Photoluminescence measurements at different temperatures have been performed to investigate the optical response of a two-dimensional electron gas in n-type wide parabolic quantum wells. A series of samples with different well widths in the range of 1000-3000 A was analyzed. Many-body effects, usually observed in the recombination process of a two-dimensional electron gas, appear as a strong enhancement in the photoluminescence spectra at the Fermi level at low temperature only in the thinnest parabolic quantum wells. The suppression of the many-body effect in the thicker quantum wells was attributed to the decrease of the overlap between the wavefunctions of the photocreated holes and the two-dimensional electrons belonging to the highest occupied electron subband. (C) 2007 American Institute of Physics.
Resumo:
Thirty-two Polwarth sheep of ages up to 1 year were observed under temperatures varying from 10.5 to 46.5°C. The following blood cell counts were made: erythrocyte (RBC), leucocyte (WBC), eosinophil (EOS), neutrophil (NEU), lymphocyte (LYM) and monocyte (MON). Other traits measured were: haemoglobin (HB), haematocrit (HT), blood glucose (GLU) and serum protein (PROT). Multivariate analysis of variance was used and the results showed a significant (P<0.001) effect for the interaction of shearing and temperature treatment. Under temperatures >25°C, sheep presented a decrease of RBC, WBC, HB and HT, these differences being greater in the shorn than in the unshorn animals. Unshorn animals presented higher variations in EOS, NEU, LYM, MON and GLU. Blood glucose increased under high temperatures in the shorn animals (from 56.36±0.65 mg/100 ml to 60.52±0.69 mg/100 ml) as in the unshorn animals (from 54.72±0.74 mg/100 ml to 57.56±0.77 mg/100 ml). © 1992 International Society of Biometeorology.
Resumo:
The objective of the study was establishing the anatomical-structural differences between the skin of non-wool sheep of the Morada Nova breed and wool-on sheep of the Polwarth or Ideal breeds and their relations to the physical-mechanical characteristics of their leather after tanning. Ten animals of both breeds were used, with five animals of approximately one and four years of age of each breed. The animals were slaughtered, and immediately after skinning, samples were taken viewing the microtomy of the skin in the dorsal, lateral, ventral, hind and palette regions, parallel and perpendicular to the head-tail axle, and perpendicular to the grain of the skin. The skins were depilated, chromium-tanned and re-tanned. From the leather, three samples were taken from the two directions considered from the regions studied for physical-mechanical analysis, for tension and tear resistance and distension on the lastometer. The average of the results of the physical-mechanical analysis were compared by Tukey test at the levels of 1 and 5% probability. The breed, the age, the region and the position exerted a positive effect on the values of the resistance of the leather to tension for the Morada Nova four year old sheep, reaching a minimum of 200 kg/cm . The region and the position exerted a positive effect on the values of tear-resistence of the leather for both breeds studied, reaching a minimum of 40 kg/cm. The resistance of the leather on distension was superior to 8 mm, for all the animals studied, not influenced by breed, age, region or position. The skin of the Ideal sheep presented a thermostatic skin layer greater than the reticular layer with great folicular and glandular density, contrary to the skin of the Morada Nova sheep where the thermostatic and reticular layers are of approximately the same thickness, with less folicular and glandular density.
Resumo:
Oral administration with solid dosage forms is a common route in the drug therapy widely used. The drug release by the disintegration process occurs in several gastrointestinal tract (GIT) regions. AC Biosusceptometry (ACB) was originally proposal to characterize the disintegration process of tablets in vitro and in the human stomach, through changes in magnetic signals. The aim of this work was to employ a multisensor ACB system to monitoring magnetic tablets and capsules in the human GIT and to obtain the magnetic images of the disintegration process. The ACB showed accuracy to quantify the gastric residence time, the intestinal transit time and the magnetic images allowed to visualize the disintegration of magnetic formulations in the GIT. The ACB is a non-invasive, radiation free technique, completely safe and harmless to the volunteers and had demonstrated potential to evaluate pharmaceutical dosage forms in the human gastrointestinal tract. © 2005 IEEE.
Resumo:
Purpose: The objective of this study was to evaluate the position of the mandibular lingula (ML) to provide data for inferior alveolar nerve block techniques in children. Methods: One hundred fifty-four panoramic radiographs of 7- to 10-year-old boys and girls were analyzed. Measurements were taken from the ML to the occlusal plane, and the percentile distances of the ML to ramal borders were determined. Results: The distance between the ML and the occlusal plane showed a gradual increase, but only in the male group was it statistically significant. MLs ratio position on the ramus remained constant in all analyzed groups. In the 7-year-old group, the ML was observed above the occlusal plane in 70% of girls and 55% of boys. That percentage reached 85% of all children by age 10. Conclusions: The mandibular lingula's ratio position remained constant. Inferior alveolar anesthesia should be administered at least 6 mm above the occlusal plane in 7- to 8-year-old children, while 10 mm could be indicated for 9- to 10-year-old children. The mandibular lingula should be considered a reliable reference for further studies of inferior alveolar nerve block techniques.
Resumo:
Background: Recent clinical studies have described maxillary sinus floor augmentation by simply elevating the maxillary sinus membrane without the use of adjunctive grafting materials. Purpose: This experimental study aimed at comparing the histologic outcomes of sinus membrane elevation and simultaneous placement of implants with and without adjunctive autogenous bone grafts. The purpose was also to investigate the role played by the implant surface in osseointegration under such circumstances. Materials and Methods: Four tufted capuchin primates had all upper premolars and the first molar extracted bilaterally. Four months later, the animals underwent maxillary sinus membrane elevation surgery using a replaceable bone window technique. The schneiderian membrane was kept elevated by insertion of two implants (turned and oxidized, Brånemark System®, Nobel Biocare AB, Göteborg, Sweden) in both sinuses. The right sinus was left with no additional treatment, whereas the left sinus was filled with autogenous bone graft. Implant stability was assessed through resonance frequency analysis (Osstell™, Integration Diagnostics AB, Göteborg, Sweden) at installation and at sacrifice. The pattern of bone formation in the experimental sites and related to the different implant surfaces was investigated using fluorochromes. The animals were sacrificed 6 months after the maxillary sinus floor augmentation procedure for histology and histomorphometry (bone-implant contact, bone area in threads, and bone area in rectangle). Results: The results showed no differences between membrane-elevated and grafted sites regarding implant stability, bone-implant contacts, and bone area within and outside implant threads. The oxidized implants exhibited improved integration compared with turned ones as higher values of bone-implant contact and bone area within threads were observed. Conclusions: The amount of augmented bone tissue in the maxillary sinus after sinus membrane elevation with or without adjunctive autogenous bone grafts does not differ after 6 months of healing. New bone is frequently deposited in contact with the schneiderian membrane in coagulum-alone sites, indicating the osteoinductive potential of the membrane. Oxidized implants show a stronger bone tissue response than turned implants in sinus floor augmentation procedures. © 2006 Blackwell Publishing, Inc.
Resumo:
The biomagnetic technique called Alternate Current Biosusceptometry (ACB) is a proposal to evaluate a multiparticulate drug delivery system in the human gastrointestinal tract. Results show that ACB was able to quantify the gastrointestinal transit and spreading of the magnetic material and is an attractive tool for pharmaceutical research. © 2007.
Resumo:
We employed ACB to characterize Gastric Emptying Time (GET - T1/2) and Gastric Activity Contraction (GAC) in dogs after erythromycin administration. An erythromycin dose of 50 mg was infused, after 24 h of fasting. Without erythromycin administration, ACB recorded GET of 157.5 ± 13.6 min (mean ± SD) and GAC of 4.4 ± 0.5 cpm (cycles per minute). After erythromycin administration was measured a GET of 84.2 ± 19.7 min. GAC was measured before, during and after erythromycin administration and results were, respectively, 4.4 ± 0.5, 4.9 ± 0.6 and 4.2 ± 0.3 cpm. Erythromycin produced efficient prokinetic action in gastric emptying and increased gastric motility in dogs. © 2007 Elsevier B.V. All rights reserved.
Resumo:
Aicardi-Goutières syndrome (AGS) is a genetic encephalopathy whose clinical features mimic those of acquired in utero viral infection. AGS exhibits locus heterogeneity, with mutations identified in genes encoding the 3′→5′ exonuclease TREX1 and the three subunits of the RNASEH2 endonuclease complex. To define the molecular spectrum of AGS, we performed mutation screening in patients, from 127 pedigrees, with a clinical diagnosis of the disease. Biallelic mutations in TREX1, RNASEH2A, RNASEH2B, and RNASEH2C were observed in 31, 3, 47, and 18 families, respectively. In five families, we identified an RNASEH2A or RNASEH2B mutation on one allele only. In one child, the disease occurred because of a de novo heterozygous TREX1 mutation. In 22 families, no mutations were found. Null mutations were common in TREX1, although a specific missense mutation was observed frequently in patients from northern Europe. Almost all mutations in RNASEH2A, RNASEH2B, and RNASEH2C were missense. We identified an RNASEH2C founder mutation in 13 Pakistani families. We also collected clinical data from 123 mutation-positive patients. Two clinical presentations could be delineated: an early-onset neonatal form, highly reminiscent of congenital infection seen particularly with TREX1 mutations, and a later-onset presentation, sometimes occurring after several months of normal development and occasionally associated with remarkably preserved neurological function, most frequently due to RNASEH2B mutations. Mortality was correlated with genotype; 34.3% of patients with TREX1, RNASEH2A, and RNASEH2C mutations versus 8.0% RNASEH2B mutation-positive patients were known to have died (P = .001). Our analysis defines the phenotypic spectrum of AGS and suggests a coherent mutation-screening strategy in this heterogeneous disorder. Additionally, our data indicate that at least one further AGS-causing gene remains to be identified. © 2007 by The American Society of Human Genetics. All rights reserved.
A novel biomagnetic instrumentation with four magnetoresistive sensors to evaluate gastric motility.
Resumo:
A novel instrumentation using anisotropic magnetoresistive (AMR) sensors associated with magnetic coils excitation was developed to evaluate gastrointestinal tract motility parameters. The susceptometer has four sensors that were used to measure the gastric activity contractions (GAC) in anaesthetized dogs, its performance was evaluated by manometry with good results.
Resumo:
Background: Previous studies have shown that membrane elevation results in predictable bone formation in the maxillary sinus provided that implants can be placed as tent poles. In situations with an extremely thin residual crest which impairs implant placement, it is possible that a space-making device can be used under the sinus membrane to promote bone formation prior to placement of implants. Purpose: The present study was conducted to test the hypothesis that the use of a space-making device for elevation of the sinus membrane will result in predictable bone formation at the maxillary sinus floor to allow placement of dental implants. Materials and Methods: Eight tufted capuchin primates underwent bilateral sinus membrane elevation surgery, and a bioresorbable space-making device, about 6 mm wide and 6 mm in height, was placed below the elevated membrane on the sinus floor. An oxidized implant (Nobel Biocare AB, Gothenburg, Sweden) was installed in the residual bone protruding into the created space at one side while the other side was left without an implant. Four animals were sacrificed after 6 months of healing. The remaining four animals received a second implant in the side with a space-making device only and followed for another 3 months before sacrifice. Implant stability was assessed through resonance frequency analysis (RFA) using the Osstell™ (Osstell AB, Gothenburg, Sweden) at installation, 6 months and 9 months after the first surgery. The bone-implant contact (BIC) and bone area inside the threads (BA) were histometrically evaluated in ground sections. Results: Histologically there were only minor or no signs of bone formation in the sites with a space-making device only. Sites with simultaneous implant placement showed bone formation along the implant surface. Sites with delayed implant placement showed minor or no bone formation and/or formation of a dense fibrous tissue along the apical part of the implant surface. In the latter group the apical part of the implant was not covered with the membrane but protruded into the sinus cavity. Conclusions: The use of a space-making device, with the design used in the present study, does not result in bone formation at the sinus floor. However, membrane elevation and simultaneous placement of the device and an implant does result in bone formation at the implant surface while sites with implants placed 6 months after membrane elevation show only small amounts of bone formation. It is suggested that lack of stabilization of the device and/or a too extensive elevation of the membrane may explain the results. © 2009, Wiley Periodicals, Inc.
Resumo:
In this work the electronic structure of undoped AlGaAs/GaAs wide parabolic quantum wells (PQWs) with different well widths (1000 and 3000 ) were investigated by means of photoluminescence (PL) measurements. Due to the particular potential shape, the sample structure confines photocreated carriers with almost three-dimensional characteristics. Our data show that depending on the well width thickness it is possible to observe very narrow structures in the PL spectra, which were ascribed to emissions associated to the recombination of confined 1s-excitons of the parabolic potential wells. From our measurements, the exciton binding energies (of a few meV) were estimated. Besides the exciton emission, we have also observed PL emissions associated to electrons in the excited subbands of the PQWs. © 2010 IOP Publishing Ltd.