111 resultados para Administrative Intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work an analysis of the Judd-Ofelt phenomenological Ωλ intensity parameters for the Pr3+ ion in fluoroindate glass is made. Different Pr3+ concentrations, namely 1, 2, 3 and 4 mol% are used. The experimental oscillator strengths have been determined from the absorption spectra. A consistent set of parameters is obtained only with the inclusion of odd rank third order intensity parameters and if the band at 21 470 cm-1 is assigned to the 3H4 → 3P1 transition and the 1I6 component is incorporated in the 3H4 → 3P2 transition at 22 700 cm-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the bevahior of the phenomenological 4f-4f intensity parameters in compounds of the Nd ion with glycine, L-aspartic acid, L-glutamic acid, L-histidine, DL-malic acid and Aspartame™ in aqueous solution, as a function of the pK values and partial charges on the oxygens of the carboxylate groups of these molecules. The results are discussed and qualitatively interpreted in terms of the forced electric dipole and dynamic coupling mechanisms of the 4f-4f intensities, thus indicating that the forced electric dipole mechanism is dominant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

β-Adrenoreceptor blockade is reported to impair endurance, power output and work capacity in healthy subjects and patients with hypertension. The purpose of this study was to investigate the effect in eighth athletic males of an acute β-adrenergic blockade with propranolol on their individual power output corresponding to a defined lactate minimum (LM). Eight fit males (cyclist or triathlete) performed a protocol to determine the power output corresponding to their individual LM (defined from an incremental exercise test after a rapidly induced exercise lactic acidosis). This protocol was performed twice in a double-blind randomized order by each athlete first ingesting propranolol (80mg) and in a second trial a placebo, 120 minutes respectively prior to the test sequence. The blood lactate concentration obtained 7 minutes after anaerobic exercise (a Wingate test) was significantly lower after acute β-adrenergic blockade (8.6 ± 1.6mM) than under the placebo condition (11.7 ± 1.6mM). The work rate at the LM was lowered from 215.0 ± 18.6 to 184.0 ± 18.6 watts and heart rate at the LM was reduced from 165 ± 1.5 to 132 ± 2.2 beats/minute as a result of the blockade. There was a non-significant correlation (r = 0.29) between the power output at the LM with and without acute β-adrenergic blockade. In conclusion, since the intensity corresponding to the LM is related to aerobic performance, the results of the present study, are able to explain in part, the reduction in aerobic power output produced during β-adrenergic blockade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tissue repair is an integration of dynamic interactive processes that involves soluble mediators, blood components, production of extra-cellular matrix and mesenchymal cells. Many studies involving the use of LLLT shows that the healing process is favored by such therapy. The aim of this work was to evaluate, through histological analysis, the tissue effects of cutaneous wounds submitted to different intensities and a same irradiation dose with lasers in λ670 or λ685nm. Eighteen animals were divided in two experimental groups according to wavelength used (λ670 or λ685nm). Each one of these groups was divided still in three subgroups of three animals each, related to the intensity of applied irradiation (2, 15 or 25mW). Twelve animals acted as untreated controls and were not irradiated. The irradiation was carried out during seven days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 hours, routinely prepared to wax, stained with H&E and analyzed under light microscopy. The histological characteristics observed, so much in the irradiated animals, as in the control, they are indicative of a substitution repair process, however, the LLLT modulatory positive effect was observed, in the healing process, mainly associate to the use of the shorter wavelength and low power. The results of the present study indicate that LLLT improves cutaneous wound repair and best results are achieved when higher potencies associated to short wavelengths or lower potencies associated to higher wavelengths are used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of low-intensity pulsed ultrasound on wound healing were evaluated at the graft-cornea transition in dogs following lamellar keratoplasty using tunica vaginalis preserved in 98% glycerin. Twenty-one dogs were subdivided into three groups of seven animals. The first group (W/US) received daily treatment of low-intensity pulsed ultrasound (20 mW/cm 2) for 15 min for the first 10 days post surgery. The second group (N/US) was submitted to the same procedure but with the ultrasound apparatus turned off. The third group, the control (CO), underwent the surgical procedure only. The animals were clinically evaluated during the initial (1-15 days), intermediate (16-30 days) and late (31-120 days) postoperative period. The corneas were evaluated by light microscopy at 1, 3, 7, 15, 30, 60 and 120 days after surgery. Clinically, there were no differences which would promote an advantage to any of the treatments. Light microscopy, however, revealed more extensive vascularization and more advanced wound healing in the W/US group, as well as a tendency towards early graft incorporation. Based on the present results, low-intensity pulsed ultrasound shows advantages, especially in situations where trophic support is a mandatory condition, facilitating better graft incorporation and rapid recovery of stromal organization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of the present investigation was to assess the histological effects of different wavelengths and intensities on the healing process of cutaneous wounds. Background Data: Tissue repair is a dynamic interactive process which involves mediators, cells and extra-cellular matrix. Several reports on the use of laser therapy have shown that the healing process is positively affected when the correct parameters are used. Methods: Eighteen standardized wounds were surgically created on the dorsum of male and female Wistar rats, which were subsequently divided into two experimental groups according to wavelength used λ.670 or λ685 nm) for lasertherapy (LLLT). Each group was divided into three subgroups of three animals according to the intensity of the applied irradiation (2,15, or 25 mW). Twelve animals were used as entreated controls and were not irradiated. The irradiation was carried out during seven consecutive days. The animals were sacrificed eight days after surgery. The specimens were removed, kept in 4% formaldehyde for 24 h, routinely prepared to wax, stained with H&E, and analyzed under light microscopy. Results: For both groups, light microscopy showed a substitution repair process; however, when LLLT was used, a positive biomodulatory effect was detectable, chiefly associated with shorter wavelength and low intensity. Conclusions: The results of the present study indicate that LLLT improved cutaneous wound repair and that the effect is a result of an inversely proportional relationship between wavelength and intensity, with treatment more effective when combining higher intensity with short wavelength or lower intensity with higher wavelength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diabetes Mellitus is a condition that results in a delay of the wound healing process, that is associated with an insufficient production of collagen, a decrease of the amount of collagen fibrils and deficient blood flow in the wound area. It is suggested that Low Intensity Laser Therapy acts by improving wound healing in normal organisms, accelerating tissue regeneration. The aim of this work was to investigate the biostimulatory effect of the HeNe laser irradiation, at 632.8 nm, on wound healing in 15 male rats suffering from diabetes induced by Streptozotocin, compared to 15 control diabetic animals. Irradiation parameters were: laser power of 15mW, exposition time of 17 s., irradiated area of 0.025 cm 2 and laser energy density of 10 J/cm 2. Full-thickness skin squared samples, with 5 mm of non-injured tissue around the wound, were obtained at 4, 7 and 15 days after wounding procedure (5 treated and 5 control animals each time). The histopathologic analysis performed by haematoxylin-eosin staining. Results suggested that the irradiation of diabetic rats was efficient for wound healing. Treated group presented better quality of the wound tissues by the macroscopic observation than control group and the microscopic analysis demonstrated that treated animals had better histopathologic evaluation than non treated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the effectiveness of low intensity laser therapy (LILT) in 30 patients presenting temporomandibular joint (TMJ) pain and mandibular dysfunction in a random and double-blind research design. The sample, divided into experimental group (1) and placebo group (2), was submitted to the treatment with infrared laser (780 nm, 30 mW, 10 s, 6.3 J/cm2) at three TMJ points. The treatment was evaluated throughout six sessions and 15, 30 and 60 days after the end of the therapy, through visual analogue scale (VAS), range of mandibular movements and TMJ pressure pain threshold. The results showed a reduction in VAS (p < 0.001) and through the ANOVA with repeated measures it was observed that the groups did not present statistically significant differences (P = 0.2060), as the averages of the evaluation times (P = 0.3955) and the interaction groups evaluation times (P = 0.3024), considering the MVO. The same occurred for RLE (P = 0.2988, P = 0.1762 and P = 0.7970), LLE (P = 0.3265, P = 0.4143 and P = 0.0696), PPTD (P = 0.1558, P = 0.4695 and P = 0.0737) and PPTE (P = 0.2376, P = 0.3203 and P = 0.0624). For PE, there were not statistically significant differences for groups (P = 0.7017) and the interaction groups evaluation times (P = 0.6678), even so in both groups the PE varied with time (P = 0.0069). © 2005 Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a low-noise highsensitivity current-to-voltage converter, a microcontroller and a digital display. The response of the instrument is nonlinear with the intensity of the radiation. The precision is better than 3%. The equipment is inexpensive, rugged, simple to construct and has good long-term stability. © 2009 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effect of acute exercise and exercise training at the anaerobic threshold (AT) intensity on aerobic conditioning and insulin secretion by pancreatic islets, adult male Wistar rats were submitted to the lactate minimum test (LMT) for AT determination. Half of the animals were submitted to swimming exercise training (trained), 1 h/day, 5 days/week during 8 weeks, with an overload equivalent to the AT. The other half was kept sedentary. At the end of the experimental period, the rats were submitted to an oral glucose tolerance test and to another LMT. Then, the animals were sacrificed at rest or immediately after 20 minutes of swimming exercise at the AT intensity for pancreatic islets isolation. At the end of the experiment mean workload (% bw) at AT was higher and blood lactate concentration (mmol/L) was lower in the trained than in the control group. Rats trained at the AT intensity showed no alteration in the areas under blood glucose and insulin during OGTT test. Islet insulin content of trained rats was higher than in the sedentary rats while islet glucose uptake did not differ among the groups. The static insulin secretion in response to the high glucose concentration (16.7 mM) of the sedentary group at rest was lower than the sedentary group submitted to the acute exercise and the inverse was observed in relation to the trained groups. physical training at the AT intensity improved the aerobic condition and altered insulin secretory pattern by pancreatic islets. © 2010 Landes Bioscience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The aim of the study was to verify whether endurance training may induce changes on the percentage of peak heart rate (% peak HR) at the lactate threshold (LT) intensity in untrained elderly. Methods. Sixteen healthy men (64.3 ± 4.1 yrs) underwent an incremental test on cycloergometer to determine the LT and the corresponding % peak HR at LT intensity. Afterwards, they were randomly distributed into two groups (n = 8 each): endurance training (ET) and control (C). The ET exercised 3 days a week for 12 weeks. The training session was divided into warm-up (5 min at 50% of LT;), a main part, and a cool-down (5 min 50% below of LT). The main part had a gradual increased volume through the weeks of 2 min. The initial volume on the 1st week was 25 min reaching 47 min at the 12th week. The relative intensity was kept constant (90 to 100% of LT). Results. After 12 weeks, the % peak HR at LT did not change significantly for both groups P > 0.05 (ET 82.9 ± 4.1 vs. 82.5 ± 3.4 and Ç 80.2 ± 7.1 vs. 81.8 ± 7.1). Conclusion. We conclude that endurance training proposed does not change the relative intensity at LT in elderly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of mean intensity of parasitism for colony-forming sessile protozoan such as Epistylis has been a great problem in parasitological studies. Some alternatives have been proposed by researchers for laboratory and field conditions. This study describes the criteria to establish the parasitic intensity score for epistylidid infestation in fish. Parasite distribution and the host-parasite relationship in four species of Brazilian cultured catfish and their hybrids are discussed. The highest prevalence rates were found in the hybrid jundiara, Leiarius marmoratus male × Pseudoplatystoma reticulatum female (96.4 %), followed by jurupoca, Hemisorubim platyrhynchos (60 %), and the hybrid surubim, Pseudoplatystoma corruscans male × P. reticulatum female (52.7 %). Positive correlation between parasitic intensity score and the fish size, weight, and relative condition factor were also observed. These findings indicate that Epistylis infestation in Brazilian catfish is an emerging disease in cultured fish. © 2012 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Previous studies with long-term average spectrum (LTAS) showed the importance of the glottal source for understanding the projected voices of actresses. In this study, electroglottographic (EGG) analysis was used to investigate the contribution of the glottal source to the projected voice, comparing actresses and nonactresses' voices, in different levels of intensity. Method: Thirty actresses and 30 nonactresses sustained vowels in habitual, moderate, and loud intensity levels. The EGG variables were contact quotient (CQ), closing quotient (QCQ), and opening quotient (QOQ). Other variables were sound pressure level (SPL) and fundamental frequency (F0). A KayPENTAX EGG was used. Variables were inputted in a general linear model. Results/Discussion: Actresses showed significantly higher values for SPL, in all levels, and both groups increased SPL significantly while changing from habitual to moderate and further to loud. There were no significant differences between groups for EGG quotients. There were significant differences between the levels only for F0 and CQ for both groups. Conclusion: SPL was significantly higher among actresses in all intensity levels, but in the EGG analysis, no differences were found. This apparently weak contribution of the glottal source in the supposedly projected voices of actresses, contrary to previous LTAS studies, might be because of a higher subglottal pressure or perhaps greater vocal tract contribution in SPL. Results from the present study suggest that trained subjects did not produce a significant higher SPL than untrained individuals by increasing the cost in terms of higher vocal fold collision and hence more impact stress. Future researches should explore the difference between trained and nontrained voices by aerodynamic measurements to evaluate the relationship between physiologic findings and the acoustic and EGG data. Moreover, further studies should consider both types of vocal tasks, sustained vowel and running speech, for both EGG and LTAS analysis. © 2013 The Voice Foundation.