289 resultados para Adesivos teciduais
Resumo:
The adhesives used in the production of engineered boards have been object of study over the years in order to improve the properties of the boards with less energy consumption, lower production costs and reduced environmental impact. In addition to that, process variables may affect the properties of the board. The present study aimed to characterize sheets of plywood, manufactured with two types of adhesives, under two different pressing conditions. The adhesives used for the study were Phenol-formaldehyde and Polyurethane castor oil based. The pressure of pressing was varied in a range from 75 to 160 Bar, in order to verify how they influence the physical and mechanical properties of the board. The tests performed resulted in a conclusion that shows that the moister content of the veneers interferes on the physical and mechanical tests. In general, boards produced with polyurethane resin showed superior physical and mechanical results; although the ones produced with phenol formaldehyde at a pressure of 75 Bar had always equal or higher values, compared to what is found in literature
Resumo:
This study aimed to evaluate the physico-mechanical performance of three PVA adhesive formulations according to the Brazilian standards for plywood testing and to evaluate the results with those presented in the technical literature and specified in normative documents. The study presents the production process of the panels, the obtaining of samples and, finally, the implementation of physico-mechanical characterization tests based on plywood Brazilian standards. For the panels production it was used a gramature of 120 g / m² and applied a pressure of 15 bars and two temperature combinations and pressing time for each adhesive. The commercial adhesives used were PVA 1810, PVA 1060 and Vinyltec 239. The physical tests conducted were thickness swelling, density, moisture content and water absorption. The mechanical tests were static flexion, for the determination of elasticity modulus (MOE) and rupture modulus (MOR), and shear in the glue line. Among the three formulations studied none showed good performance in the presence of water. However, other trials in the adhesive showed better results and closer to the commercially equivalent used, in the case the urea-formaldehyde, was the PVA 1810, that can be applied in non-structural uses and in environments without the presence of moisture
Resumo:
The automobile industry is increasingly interested in reducing vehicle weight for greater speed, lower fuel consumption and emissions, through innovation of materials and processes. One way to do this is to seek the replacement of conventional processes by the use of structural adhesives. Structural adhesives are highly resistant materials, which can replace rivets, bolts and welds allowing the substrate / adhesive assemble is stronger than the substrate itself. One of the major advantages of gluing with respect to welding is its esthetic appearance, since it does not leave marks. For this reason, parts to be soldered require a minimum thickness so that the marks do not appear, since the pieces from gluing have no restriction as to the thickness. By replacing the vibration welding process for gluing process of the instrument panel parts of an automobile, one obtains a reduction of the thickness of the parts and therefore it decreases the weight of the car. This work aims to study the various structural adhesives that already exist on the market to be applied on the instrument panel. The mechanical test performed to measure the maximum adhesive strength was the Lap Shear Test at 23°C (room temperature), -35°C and 85°C. The types of adhesives used were the hot-melt and the bi-component. By the results obtained, it is in favor using the bi-component for application to the union of instrument panel parts
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Following the introduction of the acid-etching technique in enamel surface, direct attachment of orthodontic appliances on the surface of the tooth and/or restorations became a routine procedure in the assembly of the fixed devices. The attainment of a success result is related to the criterion attention to the details and the steps of the bonding technique, as well as, to the knowledge of the characteristics of the adhesive materials and orthodontic brackets. This paper presents some aspects of various types of brackets and adhesives materials.
Resumo:
Introduction: It is known that self-etching adhesive systems can act as semi-permeable membranes. Objective: Evaluate the effects of additional layer of hydrophobic resin on the microtensile bond strength of self-etching one-bottle adhesives. Material and method: Sixty bovine incisors were used in this study. The facial enamel surfaces of the crowns were abraded with silicon carbide paper to expose flat, mid-coronal dentin surfaces. The following adhesives were used: Clearfil Tri S Bond (CTSB), AdheSE One (ADH) and One Coat 7.0 (OC). Each material was tested with and without applying an additional layer of hydrophobic material from the same manufacturer. Z-350 composite resin was inserted in three 1 mm increments. All adhesive restorative procedure was performed under simulated pulpal pressure and the microtensile test was performed immediately after curing the composite resin. Data were submitted to ANOVA and Tukey test (p < 0.05). Result: For all adhesives tested, the worst results were observed in groups which the additional layer of hydrophobic resin was not applied. Conclusion: The application of additional layer of hydrophobic material can improve the adhesion of self-etching all-in-one adhesive systems.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A case report of a patient who presents as chief complaint presence of stained restorations in the anterior teeth. After analysis and discussion of the clinical therapeutic approaches to be adopted, it was observed the presence of type class IV restorations on teeth 11 and 21, due to an oblique coronal fracture in the past. But the patient was not satisfied with the aesthetic result, then where was planned the realization of the removal of the restorations, for subsequently be used direct restorative materials for the correction of form, function and esthetics. The final result showed that the restorations were able to return the form, function and aesthetic dental, thereby evidencing the proven development of restorative dentistry in the solution of aesthetic problems.
Resumo:
The following is a clinical case report of a patient whose main complaint was the presence of a generalized spacing in the anterior maxillary segment. After meticulous clinical analysis and discussions of the clinical procedures to be adopted, a labial frenectomy was our first choice, so that we could reduce the diastemas directly using composite resin. It was observed that the association of clinical and restorative procedures was capable of giving back shape, function and dental aesthetics, allowing to the young patient the satisfaction of smiling without any fear.
Resumo:
Este estudo descreveu a histopatologia de rim, baço e fígado de Piaractus mesopotamicus, Prochilodus lineatus e Pseudoplatystoma fasciatum, parasitados por mixosporídios, capturados no Rio Aquidauana, MS. Após necropsia, amostras do fígado, rim cefálico e baço foram colhidas, fixadas em formalina a 10 % tamponada e processadas de acordo com a rotina histológica. Os cortes foram feitos à espessura de 5 μm e corados com hematoxilina-eosina. Foram encontrados Myxobolus porofilus em P. lineatus, M. colossomatis em P. mesopotamicus e Myxobolus spp. nas três espécies de hospedeiros. Cistos de mixosporídios no exame histopatológico foram vistos no fígado e baço de P. mesopotamicus. Mais de 50% das amostras de fígado de P mesopotamicus e P lineatus apresentou hepatodistrofia difusa. Mais de 80 % das amostras de fígado de P. fasciatum apresentou formações hialinas concêntricas e esteatose em 50% das amostras. em 95,23 % das amostras de rins de P. mesopotamicus, foram observadas alterações teciduais, e em mais de 60 % dos casos nefrodistrofia difusa moderada e congestão de sinusóides glomerulares. Alterações teciduais nas amostras de rins de P. lineatus foram observadas em menos de 20 % da amostra. No baço dos peixes ora examinados não foram encontradas lesões dignas de relato.
Resumo:
Onze cães, sem raça definida, machos, adultos, não castrados e hígidos foram submetidos à punção aspirativa com agulha fina da próstata guiada por ultrassom para avaliação citológica e, após um período mínimo de sete dias, à videolaparoscopia para obtenção de fragmento prostático para avaliação histológica. Nos exames citológicos, dois animais apresentaram alterações celulares compatíveis com hiperplasia prostática benigna. Durante a videolaparoscopia, a colheita do fragmento prostático foi realizada de maneira rápida, não sendo observada hemorragia significativa após o procedimento. Os animais não apresentaram nenhuma complicação no período pós-operatório. Verificaram-se, ao exame histológico, morfologia e estrutura celulares e teciduais nos padrões normais do parênquima prostático em 10 animais; um único cão apresentou alterações celulares e teciduais sugestivas de hiperplasia prostática benigna.