768 resultados para DENTIN SIALOPROTEIN


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the apical sealing ability and the marginal adaptation of five dental materials used in retrofillings or applied to the bevelled root surface. One hundred and forty extracted single rooted human teeth were used, divided into seven groups of twenty each. ln the first, second, third and fourth groups, the teeth were apicoectomized, submitted to cavity preparations and retrofilled with one of the following materiais: zinc free silver amalgam, a dentin bonding system plus composite resin, a glass ionomer cement ora compomer. In the fifth, sixth and seventh groups, the teeth were apicoectomized and capped on the bevelled root surface with one of the following materiais: a dentin bonding system plus composite resin, a glass ionomer cement or a compomer. Two specimens of each experimental group were evaluated for the marginal adaptation using scanning electron microscopy. The remaining 126 specimens were immersed in 2% methylene blue dye, stored for one week at 37ºC and the infiltration was evaluated with a stereomicroscope. The results showed that the glass ionomer cement presented the lowest values of marginal infiltration when used as retrofilling material, with a significant statistical difference when compared with the others tested materials. When used as apical capping, the glass ionomer cement and the compomer were equivalent and significantly better than the dentin bonding system plus composite resin. Using scanning electron microscopy, all the materials showed some slight adjustment problem. ln the retrofilling, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin, while the largest were observed with the glass ionomer cement and zinc free silver amalgam. ln the apical capping, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin and ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disadvantages generated by the acid etching of the dentin, such as an increase in its permeability, in the surface moisture and in the potential to denature the external dentinal collagen, the formation of a fragility zone and the citotoxicity of the adhesive monomers; which are all aggravated by the depth of the dentin, have stimulated new and different treatment philosophies of the dentin. The purpose of the present study, therefore, was to investigate the effects of three dentin treatments: laser irradiation, acid etching and hypermineralization, in the shear bond strength of the SMP Plus bonding system. Sixty bovine incisors were extracted and randomly selected immediatly alter the animal's death. They were kept frozen (-18°C) for no longer than 14 days. After buccal dentinal surface had been exposed, X-Rays were taken to control the dentin thickness. The specimens were separated into two groups: (1) Control, kept in distilled water at 4ºC; (2) Mineralized, kept in hypermineralized solution at 4°C for 14 days. Each group was divided into three sub-groups according to the type of dentin treatment used: group F - followed the manufacturer instructions (acid-etching + primer + bond), group AL (acid-etching + primer + bond + laser) and group LA (laser + (laser + acid-etching + primer + bond). A composite resin standard cylinder (Z100-3M) was bond to the dentinal surface and the shear bond strength performed on a Universal lnstron machine 4301, with 500 Kg load and at 0,5mm/min. speed. The analysis of variance (ANOVA) determined that the treatments influenced the shear bond strength values (p<0,05) with the following average shearing load at failure: AL (9,96 MPa), F (7,28MPa) e LA (4,87 MPa). The interaction between the two factors analyzed Group (control and mineralized) and treatment (F, AL, LA) also influenced the shear bond strength (p<0,05). The highest values were obtained...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Odontoma is a term that refers to a benign tumor of odontogenic and mixed nature, composed of epithelial and mesenchymal components. Histologically, they are compounds of different configurations including dental enamel, dentin, cementum and in some cases the pulp tissue. A slow growing asymptomatic tumor, odontoma is usually discovered through routine radiographic examination. A 3-year old male patient sought care at the School of Dentistry’s Baby Clinic (UNESP-Araçatuba), complaining of “small ball close to the teeth.” During the interview, the mother reported that the lesion was observed soon after a trauma, and evolved in less than one month. An ulcerated lesion with a 0.8 cm diameter was found during intraoral clinical examination. It was located in the inferior and anterior region of the mouth, between teeth 81 and 82, and there was also crown distalization. A radiographic examination showed a radiolucent area and root distance. In the absence of clinical and radiographic characteristics suggesting a case of odontoma, the differential diagnosis was peripheral giant cell lesion and pyogenic granuloma. So the area was punctured. Nonetheless, due to the absence of liquid, the surgical removal of the lesion was performed, followed by histological examination, which showed the definite diagnosis of a suggestive case of emerging odontoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to evaluate the effect of thermocycling on the color variation of three different composite resins . We studied was Resin Enamel on 3 levels : ( Esthetic X , Opallis and Venus ) ; Resin Dentin in three levels : ( Esthetic X , Opallis and Venus ) and Thermocycling on level 1 : ( 3,000 cycles ) ; variable was the change of color gauged by spectrophotometry . 60 specimens , subdivided into 6 groups were made : GI - Esthetic X Enamel ; GII - Esthetic X dentin ; GIII - Opallis Enamel ; GIV - Opallis dentin ; GV - Enamel and GVI Venus - Venus dentin . The specimens were prepared with a matrix to standardize samples . The inserts of incrementally resins and polymerized with a halogen light Ultralux unit ( Dabi Atlante , Brazil ) with a power of 450mW / cm ² . After fabrication , underwent color reading with a UV Visible Spectrophotometer reflection , UV -2450 ( Shimadzu , Kyoto , Japan ) , with the changes calculated by the system CIE L * a * b * . Then isolates were stored in artificial saliva at 35 ° C ± 2 ° C during 3 months containers being subjected to the effects of thermal cycling for 3000 cycles over the range of 5C to 55C . Again subjected to chromatic evaluation. For the analysis of the results of color change of the studied resins was applied ANOVA two factors at 5 % . The results showed a statistically equal resins enamel GI and GV ( p = 0.79 ) ; the same was not observed for GI and G III resins , where the color change was higher for resin G III ( p = 0.0000002 ) . The same was observed between G III and GV , where the resin enamel G III showed a statistically superior to the color change ( p = 0.0000005 ) Average . Resins to dentin was there a statistical equality between the materials studied . We conclude that the resins studied change in color and resin enamel G III was the most suffered major color changes after aging by thermocycling .