702 resultados para Resina macia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indirect composite resin systems have been routinely recommended for making restorations in distressed patients. The purpose of this study was to evaluate histologically in rats the effect of chronic stress on the reaction of subcutaneous connective tissue after implant of Artglass™. For this purpose, 60 rats were divided into four groups (GI (control), GII (stressed), GIII (Artglass™) and GIV (Artglass™. / stressed) received dorsal subcutaneous implants of polyethylene tubes containing saline solution (GI and GII) or Artglass™ (GIII and GIV). In groups of four animals were sacrificed at 7,14 and 28 days postoperatively. The results allowed to observe more intense inflammatory reaction and tissue organization later in the animals subjected to stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study aimed to assess dimensional changes in acrylic resin base and artificial teeth position after water storage and thermocycling using computer graphics measurements. Methods: Twenty-four waxed replicas were obtained from a previous upper complete denture. For linear measurements, points in cusps tips of left central incisor and second premolars and molars were marked in one of the prostheses with graphite and transferred to the others using an acrylic resin guide. The prostheses were scanned after waxing, polymerization and treatments and the images were exported to “AutoCad 2002 Today®” software for measurements. Results: There was no statistically significant difference in changes of each segment for each group and between the phases evaluated after polymerization and thermocycling. In groups I and III, the values after polymerization are higher than those after treatment, which suggests shrinkage while the prostheses in group II have expanded. Conclusion: The three groups exhibited artificial teeth movement after tests in comparison to the polymerized prosthesis. The prostheses submitted to water storage in kiln at 36ºC during seven days showed different behavior than the other groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The lateral movement presents a combination of lateral condylar and protrusive displacement on the non-working side. The objective os this study was to check the differences in the adjustment of the semiadjustable articulator starting from two different initial positions, centric relation an intercuspal position using positional records of rotusion and lateral movements in acrylic resin for the adjustment of condylar guidance as for ennett Angle. Twenty pacients dentate and assintomatic were recruited and their adjustment were performed in the semiadjustable articulator checking the differences among the studied groups, not finding statistically significant differences. Concludes that, in semiadjustable articulator adjustment, starting the montage in centric relation or intercuspal position, the results obtained for the condylar guidande and Bennett Angle aren´t statistically diferents, as well there is no difference in condylar guidance adjustment using lateral or protrusive records.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pigmentation of indirect composite resins has been one of the most common reasons that lead the restorative treatment to failure. The purpose of this study was to investigate the effect of different solutions on color stability of indirect composite resins. Five brands of indirect composite resins were tested: Adoro, Resilab, Cristobal, Sinfony and Epricord. The samples were immerged in eleven solutions (n=10): common liquid foods (coke soft drink, red wine, coffee and orange juice), mounthrinses (Listerine, Oral-B, Colgate Plax and Periogard) and bleaching agents (carbamide peroxide 16%, 7.5% and hydrogen peroxide 38%) and artificial saliva (control group). The color was measured by a spectrophotometer before and after 7, 14 and 21 days of immersion in common liquid foods, after 12, 24, 36 and 60 hours of immersion in mounthrinses and after 7 and 14 days of immersion in bleaching agents. The Cristobal and Adoro resins showed highest values of ΔE statistically significant compared to the others resin brands. Adoro’s ΔE values changed significantly after the immersion process in red wine and coffee and also between periods measured. The resins Cristobal and Sinfony showed the highest values of ΔE after the immersion process in Listerine with difference statistically significant in comparison to control group. Besides, there was difference statistically significant of the ΔE values  for  Cristobal  after  immersion  in hydrogen peroxide 7,5% in comparison to control group. It can be conclude that all the solutions promoted color change on the indirect composite resins. However, ΔE values  are  whitin  the  values clinically acceptable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alveolar bone resorption is continuous throughout the life of edentulous patients, the prosthesis mismatch can generate during speech and chewing. An alternative to this would be to destabilize the denture reline, a maneuver which aims to readjust the denture base to the rim by the addition of a plastic film to the inner surface of the prosthesis material. This procedure may be direct, when performed in the clinic, or indirect when made in prosthetic laboratory. The aim this study is to demonstrate the technical of two reline for denture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immediate complete denture is a prostheses made prior to teeth extraction, that aims to re-establish the patient aesthetics and function immediately after the removal of the remaining teeth. The objective of this paper is to report the technical procedures during the manufacture of immediate prosthesis. The study reports the clinical steps prior to teeth extraction as well as the surgical and maintenance procedures. The immediate complete denture is a viable rehabilitation method, especially to restore patients’ self-esteem, aesthetics and function promptly. An accurate planning and manufactory beholds better results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eye loss results on facial asymmetry compromising its aesthetics. Ocular prostheses are important to re-establish aesthetics; protect the anophthalmic cavity; recover function such as the redirection of lachrymatory liquid; and reintegrate the patient to society. The aim of this study was to describe a case report, demonstrating clinical and laboratorial procedures for confection of ocular prostheses and highlighting their advantages. A female patient was afflicted by toxoplasmosis, which led to the loss of her eye. An eye visceration was performed. The patient reported no previous use of ocular prosthesis. A PMMA ocular prosthesis was manufactured restoring patient’s aesthetic and facial contour. The patient was satisfied with the treatment. Therefore the present study has shown that PMMA ocular prosthesis is able to restore facial aesthetics and can be a safe and satisfactory alternative for patients that have lost their eyes due to toxoplasmosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of implant angulation and abutment type (UCLA and Estheticone) on stress distribution in screw-retained implant-supported prostheses through photoelasticity. Three models were fabricated with photoelastic resin PL-2 (Vishay, Micro-Measurements Group, Inc Raleigh, N.C., USA) containing one external hexagon implant with 3.75x10mm (Master screw, Conexão Sistemas de Prótese Ltda., Arujá, São Paulo) with 0°, 17° and 30° degrees and a screw-retained prostheses with UCLA and Estheticone abutments. The assembly was positioned in a circular polariscope; axial and oblique (45° degrees) loads of 100N were applied in fixed points on the occlusal crown surfaces by a universal testing machine. The stress generated was photographed and analyzed qualitatively with appropriate software (Adobe Photoshop®). The results demonstrated the same number of fringes for both abutment types for each angulation, with fringes increasing in the same way. A higher number of fringes were closer in the oblique loading mode. It was concluded that there was no significant difference in stress distribution in prostheses with UCLA and Estheticone abutments. Higher stress concentrations were observed with increased implant angulation. Stress concentration and intensity were higher in the oblique load than in axial load application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effects of two conditioning methods used to enhance the shear strength of orthodontic brackets bonded to porcelain surfaces. A total of 18 feldspathic specimens were used. The specimens were divided randomly into two groups (n = 9): group free silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive); group silane, the porcelain specimens were etched with hidrofuoric acid 10% (Acid Gel-Maquira) for 4 minutes followed by silane (Silano Ângelus) for 1 minute, adhesive-primer (Transbond XT) and the metallic brackets (Morelli Roth Light .022" x .030") were bonded with a light-cured microfilled resin (Transbond XT Light Cure Orthodontic Adhesive). All specimens were stored in solution of artificial saliva at ambient temperature for 24 hours. The debonding was done with shear strength through a universal testing machine (DL 500-Emic) calibrated with a fixed speed of 1mm/minute. Statical analysis was performed using the Student t test. The results indicated that in the free silane group the mean bond strength was 9,97 MPA, significantly lower than the silane group, that was 12,38 MPa (p < 0,05). The both groups were effective for bonding, although the silane group had the highest bond strength values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the demineralization around restorations class V made on the buccal and lingual surfaces of teeth when using different restorative materials. Thirty extracted teeth were randomly divided into 3 groups (n=10) according to the restorative material: Group I - Fuji II LC (GC America Inc., Alsip, Illinois, USA), Group II - Tetric (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Group III - Chelon Fil (3M/ESPE., Seefeld, Germany). The teeth were submitted to a pH-cycling model associated to a thermocycling model. Sections were made and the specimens were analyzed under a polarized light microscopy as for the presence of demineralization. Measurements were performed and the results were subjected to statistical analysis using Anova and Tukey´s Test (α=0.05). Mean values of demineralization depth (µm) according to each positions showed that the demineralization was significantly reduced when Chelon Fil (Group III) was used for all depths, when compared to fluoridated resin materials. Also, it was verified that non-fluoridated resin material, composite resin Tetric, had the lowest inhibitory effect on the development of demineralization.