620 resultados para Fluorose dentária
Resumo:
The concepts of buccal health promotion and the increase of life expectancy have contributed for the highest maintenance of dental elements. Thus, with the new alimentary and behavioral habits the irreversible loss of dental hard tissue of non-carious origin has increased substantially, being divided in attrition, erosion and abrasion. The dental erosion is a chronic pathology defined as the superficial loss of dental hard tissue as a result of a chemical process not involving bacteria caused by acid that could be intrinsic, extrinsic or unknown etiology, causing irreversible loss of mineral tissue and dentinal hypersensitivity. The aim of this paper is to present a review of literature on the main factors that can cause the injuries of erosion, including the different aspects related to its etiology, classification, diagnosis, prevention and treatment.
Resumo:
The use of implants of greater length may be more favorable for the predictability of dental implants. This statement is relevant, since the cause of failures in dental implants are more related to biomechanical complications. The aim of this study was to evaluate the influence of increase of the length around the entire body of the implant. Six models were created with the presence of only one hexagonal implant (Master Screw connection, Implant Systems, São Paulo, Brazil) of 3.75 mm x 7.0 mm (Model A), 3.75 mm x 8.5 mm (Model B ), 3.75 mm x 10.0 mm (Model C) 3.75 mm x 11.5 mm (Model D) 3.75 mm x 13.0 mm (Model E) 3.75 mm x 15.0 mm (Model F) using the method of photoelasticity. The results were visualized through a qualitative analysis of stresses (number and intensity photoelastic fringes). The model A showed a pattern of less favorable stress distribution, the oblique loading was the most detrimental to the related structures. Conclusion: The increased length allowed for a better distribution of stresses. The oblique loading was more detrimental when compared to axial loading.
Resumo:
Introdução: o tratamento com implantes dentários para a reposição de dentes na região estética exige a utilização de materiais e técnicas que permitam o máximo de naturalidade entre a restauração, os dentes vizinhos e o tecido gengival. Dessa forma, torna-se necessário criar o correto perfil de emergência para o dente, assim como a utilização de materiais com alto potencial estético. Objetivo: o objetivo do presente trabalho foi ilustrar, através de um caso clínico, a utilização de uma técnica de moldagem para a correta cópia do perfil de emergência do dente e sua transferência para o modelo de trabalho, tornando possível a confecção de uma restauração totalmente cerâmica, perfeitamente integrada ao tecido gengival. Caso clínico: paciente de 30 anos, procurou o clínica de prótese dentária com desejo de melhorar a estética dos dentes. Após diagnóstico e planejamento, foram confeccionadas 2 coroas totalmente cerâmicas sobre os dentes 12 e 21, e confecção de 1 coroa cerâmica sobre um pilar de zircônia após o estabelecimento e registro do perfil de emergência do dente 11. Conclusão: após a conclusão do tratamento, observou-se naturalidade, estética e perfeita integração entre as restaurações, os dentes remanescentes e o tecido gengival.
Resumo:
The aim of this study was to evaluate the biomechanical behavior of different implant connection types, by means of three-dimensional finite element analysis. 3 Three-dimensional models were created with a graphic modeling software: SolidWorks 2006 and Rhinoceros 4.0, and InVesalius (CTI, São Paulo, Brasil), the bone was obtained by computerized tomography of a sagittal section of the molar region. The model was composed by bone block with an implant (4 x 10 mm) (Conexão Sistemas de Prótese, São Paulo), with different implant connections: external hex, internal hex and Morse-taper with the corresponding prosthetic component Ucla or Morse-taper abutment. The Three-dimensional models were transferred to finite element software Femap 10.0 (Siemens PLM Software Inc., CA, USA), to generate a mesh, boundary conditions and loading. An axial (200N) and oblique load (100N) was applied on the occlusal surface of the crowns. Analyses were performed using the finite element software NEiNastran 9.0 (Noran Engineering, Inc., USA) and transferred to the Femap 10.0 to obtain the results; after the results were visualized using von Mises stress maps and Maximum stress principal. The results showed the stress distribution was similar between models, with a little superiority of Morse-taper connection. It was concluded that: the three connection types were biomechanical viable; The Morse-taper connection presented the better internal stress distribution; there was not significant biomechanical differences on the bone.
Resumo:
Rehabilitation of edentulous patients has been a challenge for professionals since the primary concepts and fundaments of occlusal rehabilitation. However, this philosophy has been improved by implant-supported fixed dentures that represent a predictable clinical modality on modern dentistry. Nevertheless, considering that the traditional protocol requires a long period for bone healing and definitive rehabilitation, immediate loading of implants has been advantageous for functional and esthetic rehabilitation of patients in a reduced period. The aim of this study is to discuss the biomechanical and functional fundaments of occlusion for implant-supported fixed dentures with mediate and immediate loading to provide clinical evidences for longevity of this treat ment modality based on the current literature. According to this, some prerequisites as proper bone quality, excellent primary stability, sufficient number of implants, rigid splinting, and control and mastering of biomechanical fundamentals of static and dynamic occlusion are mandatory for treatment predictability and longevity.