88 resultados para threshold detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anaerobic threshold (AT) is usually estimated as a change point problem by visual analysis of the cardiorespiratory response to incremental dynamic exercise. In this study, two phase linear (TPL) models of the linear-linear and linear-quadratic type were used for the estimation of AT. The correlation coefficient between the classical and statistical approaches was 0.88, and 0.89 after outlier exclusion. The TPL models provide a simple method for estimating AT that can be easily implemented using a digital computer for the automatic pattern recognition of AT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The long-standing discrepancy between the Gerasimov-Drell-Hearn sum rule and the analysis of pion photoproduction multipoles is greatly diminished by use of s-wave multipoles that are in accord with the predictions of chiral perturbation theory and describe the experimental data in the threshold region. The remaining difference may be due to contributions of channels with more pions and/or heavier mesons whose contributions to the sum rule remain to be investigated by a direct measurement of the photoabsorption cross sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the results of a search for the flavor-changing neutral current decay Bs 0 → μ+ μ-. using a data set with integrated luminosity of 240 pb-1 of pp̄ collisions at √s = 1.96 TeV collected with the D0 detector in run II of the Fermilab Tevatron collider. We find the upper limit on the branching fraction to be B(Bs 0 → μ+ π-) ≤ 5.0 × 10-7 at the 95% C.L. assuming no contributions from the decay Bd 0 → μ+ μ- in the signal region. This limit is the most stringent upper bound on the branching fraction Bs 0 → μ+ μ- to date. © 2005 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel and simple positive sequence detector (PSD), which is inherently self-adjustable to fundamental frequency deviations by means of a software-based PLL (Phase Locked Loop). Since the proposed positive sequence detector is not based on Fortescue's classical decomposition and no special input filtering is needed, its dynamic response may be as fast as one fundamental cycle. The digital PLL ensures that the positive sequence components can be calculated even under distorted waveform conditions and fundamental frequency deviations. For the purpose of validating the proposed models, the positive sequence detector has been implemented in a PC-based Power Quality Monitor and experimental results illustrate its good performance. The PSD algorithm has also been evaluated in the control loop of a Series Active Filter and simulation results demonstrate its effectiveness in a closed-loop system. Moreover, considering single-phase applications, this paper also proposes a general single-phase PLL and a Fundamental Wave Detector (FWD) immune to frequency variations and waveform distortions. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study was accomplished between two immobilization methodologies for the meldola's blue (MB), used to decrease the oxidation potential of NADH. The study was performed with glassy carbon electrode by electropolymerization of pyrrole and MB through the technique of cyclic voltammetry being evaluated the effect of the number of cycles to define the thickness and the stability of the film. With 25 cycles it was obtained the best result. They were also investigated the modification of the graphite electrode with film formed by the system sol-gel PPO 300 or PPO 4000 for the dip-coating, through two methods: occlusion and adsorption. The best method was it of adsorption of MB during 10 min, following by deposit of the film PPO 300, favored for the time of drying (24 hours). The adsorption of MB followed by PPO 300 deposition presented broader linear range than PPy methodology. ©2006 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a methodology for edge detection in digital images using the Canny detector, but associated with a priori edge structure focusing by a nonlinear anisotropic diffusion via the partial differential equation (PDE). This strategy aims at minimizing the effect of the well-known duality of the Canny detector, under which is not possible to simultaneously enhance the insensitivity to image noise and the localization precision of detected edges. The process of anisotropic diffusion via thePDE is used to a priori focus the edge structure due to its notable characteristic in selectively smoothing the image, leaving the homogeneous regions strongly smoothed and mainly preserving the physical edges, i.e., those that are actually related to objects presented in the image. The solution for the mentioned duality consists in applying the Canny detector to a fine gaussian scale but only along the edge regions focused by the process of anisotropic diffusion via the PDE. The results have shown that the method is appropriate for applications involving automatic feature extraction, since it allowed the high-precision localization of thinned edges, which are usually related to objects present in the image. © Nauka/Interperiodica 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muscle fatigue can be a limiting factor to determine index as the electromyographic fatigue threshold (EMGFT) due the alterations in motivation and disconfots. This way, the purpose of this study was to identify the right biceps brachii and left biceps brachii obtained from repetitive elbow flexions at each 10% of total time. Nine healthy subjects performed the exercise named biceps curl until exhaustion with 25%, 35%, and 45% of one repetition maximum, in three different days. EMG amplitude (root mean square - RMS) was obtained for concentric contractions during these load levels and correlated with time to determine the slope values for each load and them detemine the EMGFT. The EMGFT was obtained within of each 10% of total time and they were compared by analysis of variance. The results showed a progressive increase in RMS with time, for both muscles in all loads, characterizing the muscle fatigue process, and for the EMGFT values ware not found predominantly significant differences between the execution time, as well as between muscles (right biceps × left biceps). This protocol allowed to identify the EMGFT to both muscles during the biceps curl, which was similar at different percentage of total time, indicating the possibility to reduce the length of the contraction test without the need to maintain the contraction until exhaustion. Further studies are needed to evaluate the applicability of this method to determining the effects on performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the results of a search for a narrow resonance decaying into two photons in 1.1fb-1 of data collected by the D0 experiment at the Fermilab Tevatron Collider during the period 20022006. We find no evidence for such a resonance and set a lower limit on the mass of a fermiophobic Higgs boson of mhf>100GeV at the 95% C.L. This exclusion limit exceeds those obtained in previous searches at the Fermilab Tevatron and covers a significant region of the parameter space B(hf→I I ) vs mhf which was not accessible at the CERN Large Electron-Positron Collider. © 2008 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this Letter we report on a search for long-lived particles that decay into final states with two electrons or photons. Such long-lived particles arise in a variety of theoretical models, such as hidden valleys and supersymmetry with gauge-mediated breaking. By precisely reconstructing the direction of the electromagnetic shower we are able to probe much longer lifetimes than previously explored. We see no evidence of the existence of such long-lived particles and interpret this search as a quasi model-independent limit on their production cross section, as well as a limit on a long-lived fourth generation quark. © 2008 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effect of acute exercise and exercise training at the anaerobic threshold (AT) intensity on aerobic conditioning and insulin secretion by pancreatic islets, adult male Wistar rats were submitted to the lactate minimum test (LMT) for AT determination. Half of the animals were submitted to swimming exercise training (trained), 1 h/day, 5 days/week during 8 weeks, with an overload equivalent to the AT. The other half was kept sedentary. At the end of the experimental period, the rats were submitted to an oral glucose tolerance test and to another LMT. Then, the animals were sacrificed at rest or immediately after 20 minutes of swimming exercise at the AT intensity for pancreatic islets isolation. At the end of the experiment mean workload (% bw) at AT was higher and blood lactate concentration (mmol/L) was lower in the trained than in the control group. Rats trained at the AT intensity showed no alteration in the areas under blood glucose and insulin during OGTT test. Islet insulin content of trained rats was higher than in the sedentary rats while islet glucose uptake did not differ among the groups. The static insulin secretion in response to the high glucose concentration (16.7 mM) of the sedentary group at rest was lower than the sedentary group submitted to the acute exercise and the inverse was observed in relation to the trained groups. physical training at the AT intensity improved the aerobic condition and altered insulin secretory pattern by pancreatic islets. © 2010 Landes Bioscience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/. c to 1 TeV/. c. The surface flux ratio is measured to be 1.2766±0.0032(stat.)±0.0032(syst.), independent of the muon momentum, below 100 GeV/. c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments. © 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The purpose of this study was to compare the anaerobic threshold speed (AT) obtained from fixed lactate blood concentrations (AT 4 mM and AT 3.5 mM), lactate minimum speed (LM) and critical speed (CS), determined from different distances in fifteen Brazilian national level swimmers (10 boys = 14.8 ± 0.6 years old and 5 girls = 14.6 ±0.8 year-old). Methods. The tests to determine the AT 4 mM, AT 3.5 mM, LM and CS were performed in a 25 m swimming pool and consisted of 7 or 8 evaluations separated by 24-48 h intervals. Data were submitted to analysis of variance (ANOVA) for repeated measures, followed by the post hoc Scheffé test and Pearson correlation coefficients. Significance was set at P<0.01. Results. There were no significant differences among the values for AT 4 mM and CS1 (1.34 ± 0.05 vs. 1.33 ± 0.05 m.s -1, respectively). However, AT 4 mM and CS1 were significantly higher than AT 3.5 mM (1.28 ± 0.04 m.s -1), LM (1.27 ± 0.05 m.s -1), CS2 (1.26 ± 0.06 m.s -1), CS3 (1.27 ± 0.06 m.s -1) and CS4 (1.25 ± 0.07 m.s -1). There were no significant differences among the values for AT 3.5 mM, LM, CS2, CS3 and CS4. Conclusion. The results obtained in this study suggest that the anaerobic threshold determined by a fixed lactate concentration of 3.5 mM, as well as the LM and the CS methods determined by different distances, seem to be the most appropriate indexes for the evaluation of aerobic capacity in adolescent swimmers.