224 resultados para radiology


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To survey the current radiographic prescriptions in dental implant assessment amongst dentists in Brazil.Methods: Sixty-nine dentists were interviewed during a dental implant meeting by two calibrated graduate students, using a 19-question questionnaire, considering imaging modality options both for pre-operative implant site assessment and for follow-up, particularly with respect to cost, patient radiation dose, and broad coverage of facial bones and teeth. Epi-Info 6.04 software was used to analyse the database file.Results: Approximately 63.8% of the dentists prescribed only panoramic radiography for dental implant assessment and 28.9% ordered panoramic radiography plus periapical radiography and/or conventional tomography and/or computed tomography (CT). Only 7.2% of the dentists ordered conventional tomography or CT as a single examination, although 10.1% ordered it in combination with other imaging modalities. The main reasons given for prescribing panoramic radiography were broad coverage and cost (86.4%).Conclusions: This study has shown that most of the dentists in this study prescribe panoramic radiographs in dental implant assessment based on broad coverage and cost. They are not following the American Academy of Oral and Maxillofacial Radiology recommendations regarding cross-sectional imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. Pixel intensity values (PI) and fractal dimensions (FD) were compared in selected mandibular regions on digital panoramic images of normal, osteopenic, and osteoporotic perimenopausal and postmenopausal women to evaluate their relative efficacies in detecting osteoporotic-associated bone density changes.Study design. Standardized mandibular angle, body, and canine/premolar (C/PM) regions on 54 charge-coupied device (CCD) digital panoramic images of normal and potentially osteoporotic postmenopausal women were analyzed for PI and FD. Lumbar spine and femoral neck dual-energy x-ray absorptiometry QXA) on each patient served as the reference standard examination. Pearson correlation coefficients and analysis of variance (ANOVA) were performed.Results. There was significant correlation among PI measurements (P < 0.01), and no significant correlation between FD. C/PM had significantly lower PI than control C/PM (P = 0.049).Conclusions. Osteoporotic changes in mandibular C/PM cancellous bone were detected in our study population on CCD digital panoramic images by using a robust image analysis paradigm. Future automated application of such image analysis could enable widespread, cost effective screening for osteoporosis in dental settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors present the case of a 17-year-old White male patient complaining of enlargement in the gingival region and the fundus of the left maxillary anterior vestibular sulcus. The clinicopathological diagnosis was plexiform unicystic ameloblastoma. With this report, the authors illustrate the importance and complexity of a differential diagnosis of lesions with a cystic aspect in the anterior region of the maxilla, among them inflammatory radicular cysts, odontogenic keratocysts, adenomatoid odontogenic and unicystic ameloblastoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Missing maxillary lateral incisors create an esthetic problem with specific orthodontic and prosthetic considerations. Implants are commonly used to replace congenitally missing lateral incisors in adolescent orthodontic patients. However, an interdisciplinary approach should be observed during the diagnosis, prognosis, and treatment plan to provide a result with good predictability and meet the esthetic and functional expectations of the patient. The present study describes a case of a young patient with tooth agenesis of maxillary lateral incisors, which was conducted with an integrated planning. After 5-year follow-up of 2 fixed implant-supported prostheses, clinical and radiographic examination showed the treatment to be successful. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:e22-e28)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. This study evaluated the influence of estrogen deficiency and its treatment on bone density around integrated implants.Study design. Implants were placed in female rat tibiae. The animals were assigned to 5 groups: control, sham, ovariectomy, estrogen, and alendronate. The control group was humanely killed to confirm integration of the implant. The others were submitted to ovariectomy or sham surgery. Bone density was measured by digital radiographs at 6 points on sides of the implant.Results. The analysis of radiographic bone density revealed estrogen privation had a negative impact only in the cancellous bone. The estrogen group differed significantly ( P <.05) from the ovariectomy and alendronate groups. The alendronate group presented the highest density for all evaluated regions.Conclusion. Ovariectomy caused a decrease in the radiographic bone density in the cancellous region. Estrogen replacement therapy and alendronate were effective treatments in preventing bone mass loss around integrated implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the use of a collagen-based membrane compared with no treatment on guided bone regeneration by 3-dimensional computerized microtomography (mu CT).Study Design. Defects were created between the mesial and distal premolar roots of the second and third premolars (beagle dogs; n = 8). A collagen-based membrane (Vitala; Osteogenics Biomedical Inc., TX, USA) was placed in one of the defects (membrane group; n = 16), and the other was left untreated (no-membrane group; n = 16). Left and right sides provided healing samples for 2 and 16 weeks. Three-dimensional bone architecture was acquired by mu CT and categorized as fully regenerated (F, bone height and width) or nonregenerated (N).Results. Chi-square tests (95% level of significance) showed that tooth did not have an effect on outcome (P = .5). Significantly higher F outcomes were observed at 16 weeks than 2 weeks (P = .008) and in membrane group than in no-membrane group (P = .008).Conclusions. The collagen-based membrane influenced bone regeneration at the furcation. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:437-443)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate a simple mnemonic rule (the RB-RB/LB-LB rule) for recording intra-oral radiographs with optimal projection for the control of dental implants.Methods: 30 third-year dental students received a short lesson in the RB-RB/LB-LB mnemonic rule. The rule is as follows: if right blur then raise beam (RB-RB), i.e. if implant threads are blurred at the right side of the implant, the X-ray beam direction must be raised towards the ceiling to obtain sharp threads on both implant sides; if left blur then lower beam (LB-LB), i.e. if implant threads are blurred at the left side of the implant, the X-ray beam direction must be lowered towards the floor to obtain sharp threads on both implant sides. Intra-oral radiographs of four screw-type implants placed with different inclination in a Frasaco upper or lower jaw dental model (Frasaco GmbH, Tettnang, Germany) were recorded. The students were unaware of the inclination of the implants and were instructed to re-expose each implant, implementing the mnemonic rule, until an image of the implant with acceptable quality (subjectively judged by the instructor) was obtained. Subsequently, each radiograph was blindly assessed with respect to sharpness of the implant threads and assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable and (4) hopeless.Results: For all implants, from one non-perfect exposure to the following, a higher score was obtained in 64% of the cases, 28% received the same score and 8% obtained a lower score. Only a small variation was observed among exposures of implants with different inclination. on average, two exposures per implant (range: one to eight exposures) were needed to obtain a clinically acceptable image.Conclusion: The RB-RB/LB-LB mnemonic rule for recording intra-oral radiographs of dental implants with a correct projection was easy to implement by inexperienced examiners. Dentomaxillofacial Radiology (2012) 41, 298-304. doi: 10.1259/dmfr/20861598

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The aim of this study was to detect the development of experimentally induced periapical lesions using conventional radiography and computed tomography.Study design. The root canals of dogs' teeth were exposed to the oral environment for 7 days for contamination and then sealed for 7 days (GI), 15 days (GII), 30 days (GIII), and 60 days (GIV). Immediately after each experimental period, radiographs and tomograms were taken in order to detect the occurrence of periapical bone resorption. The periapical radiographs were digitized and areas of bone resorption were measured using the VIXWIN 2000 software. Scores were assigned to the tomograms based on the progression of periapical bone resorption. The specimens were evaluated by calibrated examiners who were blinded to the groups. The radiographic results were analyzed by ANOVA and Tukey's test (P <.05) and the tomographic results were analyzed by Kruskal-Wallis and Dunn's tests (P <.05).Results. The radiographic evaluation did not reveal periapical lesions at the 7-day control. Lesions were radiographically visible at 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (P <.05). At 60 days, lesions were detected in all specimens, presenting larger dimensions than those of the earlier evaluation periods (P <.05). The tomographic evaluation detected lesions at 7 and 15 days (32.5% and 83.3% of the cases, respectively). Lesions were detected in all specimens at the 30- and 60-day periods, when the greatest values of bone resorption were observed (P <.05).Conclusions. Tomography was able to detect periapical lesion development in its initial stages, even when the lesions were undetectable radiographically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The present study evaluated the dynamics of the development of periapical lesions.Study design. Root canals from dogs' teeth were exposed to the oral environment, and then sealed for 7 days (Group A), 15 days (Group B), 30 days (Group C), and 60 days (Group D). After each experimental period, radiographs were taken to detect periapical bone resorption. In addition, histological sections from the periapical region were prepared. The radiographic and histological results were analyzed by ANOVA and Tukey's, Wilcoxon, and Pearson's tests. Significance level was set at 5%.Results. Lesions were radiographically visible at 15 and 30 days, and had similar size at these periods (P > .05). At 60 days, lesions were larger than in the other periods (P < .05). Bone resorption was detected histologically at 7 days. The greatest values of bone resorption were observed at the 30- and 60-day periods (P < .05). The results of the methods of evaluation were similar only at the 30-day period. There was no correlation between the radiographic and histological results.Conclusions. Periapical radiography did not provide detection of periapical lesion in its initial stages. The periapical lesions became more evident radiographically when the bone resorption area increased. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;107:442-447)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.