156 resultados para plasma treatment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ti-6Al-4V alloy is one of the most frequently used Ti alloys with diverse applications in aerospace and biomedical areas due to its favorable mechanical properties, corrosion resistance and biocompatibility. Meanwhile, its surface can stiffer intense corrosion caused by wear processes due to its poor tribological properties. Thus in the present study, PIII processing of Ti-6Al-4V alloy was carried out to evaluate its corrosion resistance in 3.5% NaCl solution. Two different sets of Ti-6Al-4V samples were PIII treated, varying the plasma gases and the treatment time. The corrosion behavior is correlated with the surface morphology, and the nitrogen content. SEM micrographs of the untreated sample reveal a typical two-phase structure. PIII processing promotes surface sputtering and the surface morphology is completely different for samples treated with N-2/H-2 mixture and N-2 only. The highest penetration of nitrogen (similar to 88 nm), corresponding to 33% of N-2 was obtained for the sample treated with N-2/H-2 mixture for 1:30 h. The corrosion behavior of the samples was investigated by a potentiodynamic polarization method. A large passive region of the polarization curves (similar to 1.5 V), associated with the formation of a protective film, was observed for all samples. The passive current density (similar to 3 x 10(-6) A cm(-2)) of the PIII-treated Ti-6Al-4V samples is about 10 times higher than for the untreated sample. This current value is still rather low and maintains good corrosion resistance. The anodic branches of the polarization curves for all treated Ti-6Al-4V samples demonstrate also that the oxide films break down at approximately 1.6 V, forming an active region. Although the sample treated by N-2/H-2 mixture for 1.30 It has thicker nitrogen enriched layer, better corrosion resistance is obtained for the PIII process performed with N, gas only. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrochemical corrosion measurements of AISI H13 steel treated by Pill process in 3.5% (wt) NaCl solution were investigated. So far the corrosion behavior of AISI H 13 steel by Pill has not been studied. The electrochemical results are correlated with the surface morphology, nitrogen content and hardness of the nitride layer. Ion implantation of nitrogen into H 13 steel was carried out by Pill technique. SEM examination revealed a generalized corrosion and porosity over all analyzed sample surfaces. Penetration of nitrogen reaching more than 20 gm was achieved at 450 degrees C and hardness as high as 1340 HV (factor of 2.7 enhancement over standard tempered and annealed H 13) was reached by a high power, 9 h Pill treatment. The corrosion behavior of the samples was studied by potentiodynamic polarization method. The noblest corrosion behavior was observed for the samples treated by PIII at 450 degrees C, during 9 h. Anodic branches of polarization curves of PIII processed samples show a passive region associated with the formation of a protective film. The passive region current density of PIII treated H13 samples (3.5 x 10(-6) A/cm(2)) is about 270 times lower than the one of untreated specimens, which demonstrates the higher corrosion resistance for the Pill treated H 13 samples. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the effect of nitrogen Plasma Immersion Ion Implantation (PIII) on chemical structure, refraction index and surface hardness of plasma-polymerized hexamethyldisilazane (PPHMDSN) thin films. Firstly, polymeric films were deposited at 13.56 MHz radiofrequency (RF) Plasma Enhanced Chemical Vapour Deposition (PECVD) and then, were treated by nitrogen PIII from 15 to 60 min. Fourier Transformed Infrared (FTIR) spectroscopy was employed to analyse the molecular structure of the samples, and it revealed that vibrations modes at 3350 cm(-1), 2960 cm(-1), 1650 cm(-1), 1250 cm(-1) and 1050 cm(-1) were altered by nitrogen PIII. Visible-ultraviolet (vis-UV) spectroscopy was used to evaluate film refractive index and the results showed a slight increase from 1.6 to 1.8 following the implantation time. Nanoindentation revealed a surface hardness rise from 0.5 to 2.3 GPa as PIII treatment time increased. These results indicate nitrogen PIII is very promising in improving optical and mechanical properties of PPHMDSN films.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tuberculosis (TB), a chronic infectious disease, is a major cause of morbidity and mortality worldwide. Expression of iNOS and consequent production of NO during the inflammatory process is an important defense mechanism against TB bacteria. We have tested whether pulmonary TB patients undergoing anti-tuberculosis treatment present DNA damage, and whether this damage is related to oxidative stress, by evaluating total hydrophilic antioxidant capacity and iNOS expression. DNA damage in peripheral blood mononuclear cells from patients and healthy tuberculin test (PPD) positive controls was evaluated by single-cell gel electrophoresis (comet assay), and iNOS expression was measured by qPCR. We also evaluated total hydrophilic antioxidant capacity in plasma from patients and controls. Compared to controls, pulmonary TB patients under treatment presented increased DNA damage, which diminished during treatment. Also, the antioxidant capacity of these individuals was increased at the start of treatment, and reduced during treatment. TB patients showed lower iNOS expression, but expression tended to increase during treatment. Our results indicate that pulmonary TB patients under anti-TB treatment exhibit elevated DNA damage in peripheral blood mononuclear cells. This damage was not related to nitric oxide but may be due to other free radicals. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three experiments were conducted to evaluate plasma concentrations of glucose, insulin, IGF-I, and progesterone (P4) in pubertal beef heifers receiving exogenous glucose, insulin, or sometribove zinc. All heifers used had no luteal P4 synthesis but received a controlled internal drug-releasing device containing 1.38 g of P4 to estimate treatment effects on hepatic P4 degradation. In Exp. 1, 8 pubertal, nulliparous Angus x Hereford heifers (initial BW = 442 +/- 14 kg; initial age = 656 +/- 7 d) were randomly assigned to receive, in a crossover design containing 2 periods of 10 h, intravenous (i.v.) infusions (10 mL) of insulin (1 mu g/kg of BW; INS) or saline (0.9%; SAL). Treatments were administered via jugular venipuncture in 7 applications (0.15 mu g insulin/kg BW per application) 45 min apart (from 0 to 270 min). Blood samples were collected immediately before each infusion as well as at -120, -60, 330, 390, and 450 min relative to the first infusion. Heifers receiving INS had greater (P < 0.01) plasma insulin, reduced (P <= 0.04) plasma glucose and IGF-I, and similar (P = 0.62) plasma P4 concentrations compared with SAL heifers. In Exp. 2, the same heifers were assigned to receive, in a similar experimental design as Exp. 1, i.v. infusions (10 mL) of 1) insulin (1 mu g/kg BW) and glucose (0.5 g/kg BW; INS+G) or 2) SAL. Heifers receiving INS+G had greater (P <= 0.02) plasma insulin, glucose, and P4 but reduced (P = 0.01) plasma IGF-I concentrations compared with SAL heifers. In Exp. 3, the same heifers were assigned to receive, in a crossover design containing 2 periods of 14 d, subcutaneous (s.c.) injections of 1) 250 mg of sometribove zinc (BST) or 2) SAL. Blood samples were collected 3 h apart (0900, 1200, 1500, and 1800 h) from heifers on d 6, 8, and 10 relative to treatment administration (d 1). Heifers receiving BST had greater (P < 0.01) plasma glucose and IGF-I and similar (P >= 0.67) plasma insulin and P4 concentrations compared with SAL heifers. Results from this series of experiments suggested that concurrent increases in glucose and insulin are required to reduce hepatic catabolism and increase plasma concentrations of P4 in bovine females.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of lethal photosensitization and guided bone regeneration (GBR) on the treatment of ligature-induced peri-implantitis in different implant surfaces. The treatment outcome was evaluated by clinical and histometric methods. A total of 40 dental implants with four different surface coatings (10 commercially pure titanium surface (cpTi); 10 titanium plasma-sprayed (TPS); 10 acid-etched surface; 10 surface-oxide sandblasted) were inserted into five mongrel dogs. After 3 months, the animals with ligature-induced peri-implantitis were subjected to surgical treatment using a split-mouth design. The controls were treated by debridment and GBR, while the test side received an additional therapy with photosensitization, using a GaAlAs diode laser, with a wavelength of 830 nm and a power output of 50 mW for 80 s (4 J/cm(2)), and sensitized toluidine blue O (100 mu g/ml). The animals were sacrificed 5 months after therapy. The control sites presented an earlier exposition of the membranes on all coating surfaces, while the test group presented a higher bone height gain. Re-osseointegration ranged between 41.9% for the cpTi surface and 31.19% for the TPS surface in the test sites; however differences were not achieved between the surfaces. The lethal photosensitization associated with GBR allowed for better re-osseointegration at the area adjacent to the peri-implant defect regardless of the implant surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)