335 resultados para marginal mandibular resection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the anatomotopographic location of the mandibular foramen in the right and left ramus, and to verify the influence of the amount of dental alveoli on the foramen position. Thirty-five adult dry human mandibles of Araraquara Dental School, UNESP - São Paulo State University were assessed, with or without dental alveoli. Measurements were obtained, using a ruler and a digital caliper. The following distances were measured: Fl - distance between the lowest point of the mandibular incisure and the mandibular foramen (F point); FB - distance between the mandibular base and F point; FP - distance between the posterior margin of the ramus and F point; FA - distance between the anterior margin of the ramus and F point; FT - distance between the apex of the retromolar trigone and F point. The Mann-Whitney test was used to compare each measurement according to hemi-arch, and the Kruskal-Wallis test was used to analyze the influence of the presence of alveoli on the measures. For multiple comparison, Dunn's method was used. There was no statistically significant difference in the location of the mandibular foramen when compared to the right and left hemi-arches. The amount of dental alveoli influenced, significantly, only on FA and FP distances. Thus, it was concluded that the right and left mandibular ramus showed symmetry in the location of the mandibular foramen, and the amount of alveoli influenced on the distances of the anterior and posterior margins of the mandibular rams, in relation to the mandibular foramen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class 11 restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). Method and materials: Forty human caries-free molars were extracted and selected. Eighty Class 11 standardized cavities were made in the cervical wall at the cementoenamel junction (CEJ) and at the mesial and distal surfaces. The teeth were divided into four groups: G1 - adhesive system + microhybrid resin composite Z100; G2 - adhesive system + compactable resin composite Prodigy Condensable; G3 - adhesive system + flowable resin composite Revolution + Z1 00 resin composite; G4 - adhesive system + Revolution fluid resin + compactable resin composite Prodigy Condensable. The adhesive system used in this study was Scotchbond Multi-Purpose Plus. The specimens were thermocycled in baths of 5degreesC and 55degreesC for 1,000 cycles and immersed in 50% silver nitrate solution. The specimens then were sectioned and evaluated on degree of dye penetration. Results: the results were evaluated using the nonparametric Kruskall-Wallis test, which showed a statistically significant difference between groups G1 and G4, G2 and G4, and G3 and G4. Conclusions: None of the materials was able to eliminate the marginal microleakage at the cervical wall; the application of a low-viscosity resin composite combined with a compactable resin composite significantly decreased the microleakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perforation of the root canal during insertion of an intracanal post is a complication of endodontic therapy. Mineral trixoide aggregate (MTA) has been successfully used a sealer in these situations. This material has recently been formulated in white color, allowing its application in areas of esthetic concern. This is a clinical case report of a root perforation sealed with gray MTA that resulted in discoloration of the marginal gingiva. Treatment consisted of replacing gray MTA with white MTA with the aid of a dental operating microscope, producing satisfactory esthetic results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of Image Tool Software 3.0 (ITS 3.0) to detect marginal microleakage using the stereomicroscope as the validation criterion and ITS 3.0 as the tool under study.Materials and Methods: Class V cavities were prepared at the cementoenamel junction of 61 bovine incisors, and 53 halves of them were used. Using the stereomicroscope, microleakage was classified dichotomously: presence or absence. Next, ITS 3.0 was used to obtain measurements of the microleakage, so that 0.75 was taken as the cut-off point, and values equal to or greater than 0.75 indicated its presence, while values between 0.00 and 0.75 indicated its absence. Sensitivity and specificity were calculated by point and given as 95% confidence interval (95% CI).Results: The accuracy of the ITS 3.0 was verified with a sensitivity of 0.95 (95% CI: 0.89 to 1.00) and a specificity of 0.92 (95% CI: 0.84 to 0.99).Conclusion: Digital diagnosis of marginal microleakage using ITS 3.0 was sensitive and specific.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the percentage of gutta-percha (PGP) in mesial root canals of mandibular molars obturated with LC (Lateral Compaction) or SC (Single Cone) ProTaper Universal System techniques at different levels of the root. Mesial root canals of 20 human permanent molars with similar anatomical characteristics were instrumented using the ProTaper Universal rotary system technique until the F2 instrument, with 20 canals filled by SC ProTaper Universal technique and 20 canals by the LC technique. The mesial roots were sectioned transversely to 3, 5, and 7 mm from the root apex. Digital images of specimens were obtained at MIC-D digital microscope in increases of 30 to 35X. The gutta-percha area was measured using ImageTool software. Data were analyzed using two-way ANOVA and Bonferroni test (a = 0.05). The SC technique provided greater PGP than the LC technique in the apical third (3 mm) (P < 0.001). In the other thirds (5 and 7 mm) there was no statistical difference between the two techniques regarding the PGP (P > 0.05). There was no statistically significant difference between thirds of the root canal for both techniques (P > 0.05). It was concluded that SC technique provided greater PGP than the LC technique in the apical third of mesial root canals of mandibular molars. There was no difference between the two techniques regarding the PGP in the cervical and middle thirds. Microsc. Res. Tech. 75:12291232, 2012. (C) 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effect of two light-curing units (QTH and LED) on microleakage of Class II composite resin restorations with dentin cavosurface margins. Twenty extracted mandibular first premolars, free of caries and fractures were prepared two vertical slot cavities in the occluso-mesial and -destal surfaces (2 mm buccal-lingually, 2 mm proximal-axially and cervical limit in enamel) and divided into 4 equal groups (n = 8): GI and GII: packable posterior composite light-activated with LED and QTH, respectively; GIII and GIV: micro-hybrid composite resin light-activated with LED and QTH, respectively. The composite resins were applied following the manufacturer's instructions. After 24 h of water storage specimens were subjected to thermocycling for a total of 500 cycles at 5 and 55A degrees C and the teeth were then sealed with impermeable material. Teeth were immersed in 0.5% Basic fuchsin during 24 h at room temperature, and zero to three levels of penetration score were attributed. The Mann-Whitney and Kruskal-Wallis tests showed significant statistically similar (P > 0.05) from GI to GII and GIII to GIV, which the GII (2.750) had the highest mean scores and the GIII and GIV (0.875) had lowest mean scores. The use of different light-curing units has no influence on marginal integrity of Class II composite resin restorations and the proprieties of composite resins are important to reduce the microleakage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Sealing ability and bond strengths of total-etch and self-etch dentin adhesives used for immediate dentin sealing have not been assessed and established.Purpose. The purpose of this study was to determine the effectiveness of immediate dentin sealing (IDS) using total-etch or self-etch dentin adhesives on microleakage and microtensile bond strength.Material and methods. Twenty recently extracted molars were selected, and standard MOD inlay preparations were made with the gingival margins located below the cemento-enamel unction. The teeth were assigned to 4 experimental groups (n=5) according to the indirect composite restoration cementation technique used: (1) immediate dentin sealing with Adper Single Bond (TEBI); (2) conventional adhesive cementation technique using Adper Single Bond (TEAI); (3) immediate dentin sealing using Adper Prompt L-Pop (SEBI); or (4) conventional adhesive cementation technique using Adper Prompt L-Pop (SEAI). The restored teeth were thermal cycled 1,000 times between 5 degrees and 55 degrees C and then immersed in 50% ammoniacal silver nitrate. Three specimens per restoration were evaluated for microleakage, according to predefined scores, and submitted to Friedman's test (alpha-.05). The specimens were then sectioned to obtain 0.8 +/- 0.2-mm-thick sticks (with n ranging from 32 to 57 specimens) and submitted to microtensile bond strength (mu TBS) testing. The obtained data were submitted to 2-way ANOVA test (alpha=.05).Results. None of the experimental groups demonstrated complete elimination of marginal microleakage. There were significant differences in microleakage of the tested adhesives (P>.001). IDS microleakage scores were similar to those obtained using the conventional cementation technique (CCT) for both adhesives. The highest mean bond strengths were obtained with TEBI (51.1 MPa), whereas SEAI showed the lowest mean bond strengths (1.7 MPa). IDS resulted in significantly higher bond strengths than CCT (P<.001).Conclusions. Total-etch and self-etch adhesives have a significant effect on IDS. IDS resulted in high bond strengths for both adhesives; however, the microleakage was similar to that obtained with CCT (J Prosthet Dent 2009;102:1-9)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Control of microleakage represents a challenge for posterior composite restorations. The technique for composite placement may reduce microleakage. The null hypothesis of this in vitro study was that centripetal incremental insertion of composite resin would result in less microleakage than that obtained with the oblique incremental technique or bulk technique. Method and Materials: Standardized Class 2 preparations were made in 60 caries-free extracted third molars and randomly assigned to 3 groups ( n = 20): ( 1) oblique incremental insertion technique ( control), ( 2) centripetal incremental insertion technique, and ( 3) bulk insertion. The teeth were restored with a total-etch adhesive and micro-hybrid composite resin. The specimens were isolated with nail varnish except for a 2-mm-wide area around the restoration and then thermocycled ( 1,000 thermal cycles, 5 degrees C/ 55 degrees C; 30-second dwell time). The specimens were immersed in an aqueous solution of 50% silver nitrate for 24 hours, followed by 8 hours of immersion in a photo-developing solution and subsequently evaluated for leakage. The microleakage scores ( 0 to 4) obtained from the occlusal and cervical walls were analyzed with median nonparametric tests ( P <.05). Results: The null hypothesis was rejected. All techniques attained statistically similar dentin microleakage scores ( P =.15). The centripetal insertion technique displayed significantly less microleakage than the oblique technique at the enamel margins ( P =.04). Conclusion: None of the techniques eliminated marginal microleakage in Class 2 preparations. However, in occlusal areas, the centripetal technique performed significantly better than the other techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the clinical outcome of patients with mandibular angle fractures treated by intraoral access and a rectangular grid miniplate with 4 holes and stabilized with monocortical screws.Patients and Methods: This study included 45 patients with mandibular angle fractures from the Department of Oral and Maxillofacial Surgery São Paulo State University, Araraquara, Brazil, and from the Clinic of Oral and Maxillofacial Surgery at the University of Frankfurt, Germany. The 45 fractures of the mandibular angle were treated with a rectangular grid miniplate of a 2.0-mm system by an intraoral approach with monocortical screws. Clinical evaluations were postoperatively performed at 15 and 30 days and 3 and 6 months, and the complications encountered were recorded and treated.Results: The infection rate was 4.44% (2 patients), and in 1 patient it was necessary to replace hardware. This patient also had a fracture of the left mandibular body; 3 patients (6.66%) had minor occlusal changes that have been resolved with small occlusal adjustments. Before surgery, 15 patients (33.33%) presented with hypoesthesia of the inferior alveolar nerve; 4 (8.88%) had this change until the last clinical control, at 6 months.Conclusions: The rectangular grid miniplate used in this study was stable for the treatment of simple mandibular angle fractures through intraoral access, with low complication rates, easy handling, and easy adjustment, with a low cost. Concomitant mandibular fracture may increase the rate of complications. This plate should be indicated in fractures with sufficient interfragmentaty contact. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1436-1441, 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals.Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants.Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations.Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioassays were carried out seasonally to evaluate individual growth and reproduction of cladocerans, from a marginal lake, with the addition of nitrogen (N), phosphorus (P), and both N and P to natural seston; Methods: Cohorts originated from cultivated females were submitted to the following treatments: 1) lake seston, 2) lake seston + P, 3) lake seston + N, and 4) lake seston + NP; Results: The sestonic C:P and C:N molar ratios were always high and limiting, according to threshold ratios estimated for temperate lakes. P addition to seston enhanced the growth rates of one species, D. birgei. A significant higher growth rate of B. longirostris was found in the seston enriched with N compared to natural seston, as well as a higher fecundity of M. minuta. The fecundity of D. birgei was significantly higher in the seston enriched with both N and P. C, N, and P body content of cladocerans was similar to that of temperate counterparts; Conclusion: Energy limitation related to carbon content or food quality seems to be most important in controlling cladocerans' populations in the lake than food mineral content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Contribute to the understanding of the distribution of a littoral cladoceran, Pseudosida ramosa Daday, 1904, in Brazil, with special reference for the Paranapanema River basin (Southeast Brazil); Methods: The specimens were sampled in two floodplain lakes located in the middle Paranapanema River basin, in the boundary of São Paulo and Parana States, using a standard plankton net (50 [mu]m mesh size). Trinocular microscopic with camera lucida and milimetric scale was used for the observation and measurements of the specimens; Results: Only three individuals were found (in winter and summer), despite of an extensive sampling program during 17 consecutive months of observations in both lakes. The largest body length was 1,146 [mu]m. The taxonomical identification followed Korovchinsky (1992); Conclusions: This species have a wide geographical distribution in Brazil, but it is restricted to zones colonized by aquatic macrophytes and seems to occur in low population abundance. The scarcity of registers of P. ramosa demonstrates the necessity of deeper investigations of littoral habits as well as the important role of this kind of environment for the conservation of the rivers/reservoirs biota, including some possible rare species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mandibular glands of Hymenoptera are structures associated with the mandibles and constitute part of the salivary glands system. Histological studies in workers of Atta sexdens rubropilosa revealed that this gland contains two portions: a secretory and a storage portion or reservoir. Both portions are connected by means of canaliculi. The object of the present work was the study of the ultratructure of the mandibular glands of minima, media and soldier ant of A. s. rubropilosa by TEM techniques. The glands, in the three castes studied, possess a reservoir, constituted by a simple pavementous epithelium surrounded by the cuticular intima and the secretory portion is constituted by cells of rounded shape. The secretory cells, mainly of minima and soldier, were rich in smooth endoplasmic reticulum. The media worker and soldier presented a large number of mitochondria, of varying shape. Well-developed Golgi complexes were also present in the soldiers. The secretory cells in minima, media and soldier were provided with collecting intracellular canaliculi, which were linked to the reservoir through the extracellular portion. The cytoplasm of the canaliculi-forming cell was poor in organelles. In the individuals of the three castes of A. s. rubropilosa, the presence of lipid secretion granules suggested, beyond the other functions, also a possible pheromonal action. The different roles executed by the different insect castes are directly dependent on the glandular products and, consequently, on the secretory cellular characteristics. (c) 2005 Elsevier Ltd. All rights reserved.