98 resultados para likelihood ratio test
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The multipath effect affects the differential and relative positioning, even that one involving short baselines. So it is necessary to detect this effect, check the caused error level, and mainly, its removal. This paper aims at analysing and comparing some useful components in the detection of this effect. These components are the Signal to Noise Ratio (SNR), the values of MP1 and MP2 obtained from the TEQC software that indicates the multipath level in the carriers L1 and L2, the multipath repeatability in consecutive days and the elevation angle and the azimuth of the satellites. For this purpose, an experiment is carried out, comparing such components in the presence and the absence of reflector objects that cause the multipath. Not only there is clear multipath repeatability in the residuals, but it also appears in the measures SNR, MP1 and MP2, reaching up 99% of correlation. For reduction, at least, of the high frequency multipath effect, the Multi-Resolution Analysis using wavelets is applied in the double differences (DD) measures. Some statistical tests were accomplished, which indicate results improvement, and mainly, larger reliability in the solution of the ambiguities, reaching up 49% of improvement concerning the Ratio test without applying the proposed method.
Resumo:
Integer carrier phase ambiguity resolution is the key to rapid and high-precision global navigation satellite system (GNSS) positioning and navigation. As important as the integer ambiguity estimation, it is the validation of the solution, because, even when one uses an optimal, or close to optimal, integer ambiguity estimator, unacceptable integer solution can still be obtained. This can happen, for example, when the data are degraded by multipath effects, which affect the real-valued float ambiguity solution, conducting to an incorrect integer (fixed) ambiguity solution. Thus, it is important to use a statistic test that has a correct theoretical and probabilistic base, which has became possible by using the Ratio Test Integer Aperture (RTIA) estimator. The properties and underlying concept of this statistic test are shortly described. An experiment was performed using data with and without multipath. Reflector objects were placed surrounding the receiver antenna aiming to cause multipath. A method based on multiresolution analysis by wavelet transform is used to reduce the multipath of the GPS double difference (DDs) observations. So, the objective of this paper is to compare the ambiguity resolution and validation using data from these two situations: data with multipath and with multipath reduced by wavelets. Additionally, the accuracy of the estimated coordinates is also assessed by comparing with the ground truth coordinates, which were estimated using data without multipath effects. The success and fail probabilities of the RTIA were, in general, coherent and showed the efficiency and the reliability of this statistic test. After multipath mitigation, ambiguity resolution becomes more reliable and the coordinates more precise. © Springer-Verlag Berlin Heidelberg 2007.
Resumo:
This work describes a fabrication and test sequence of microvalves installed on micronozzles. The technique used to fabricate the micronozzles was powder blasting. The microvalves are actuators made from PVDF (polivinylidene fluoride), that is a piezoelectric polymer. The micronozzles have convergent-divergent shape with external diameter of 1mm and throat around 230μm. The polymer have low piezoelectric coefficient, for this reason a bimorph structure with dimensions of 2mm width and 4mm of length was build (two piezoelectric sheets were glued together with opposite polarization). Both sheets are recovered with a conductor thin film used as electrodes. Applying a voltage between the electrodes one sheet expands while the other contracts and this generate a vertical movement to the entire actuator. Appling +300V DC between the electrodes the volume flux rate, for a pressure ratio of 0.5, was 0.36 sccm. Applying -200V DC between the electrodes (that means it closed) the volume flux rate was 0.32 sccm, defining a possible range of flow between 0.32 and 0.36 sccm. The third measurement was performed using AC voltage (200V AC with frequency of 1Hz), where the actuator was oscillating. For pressure ratio of 0.5, the flow rate was 0.62 sccm. © 2008 IOP Publishing Ltd.
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR
Resumo:
The objectives of this study were to describe the potential for nitrogen retention by two techniques: comparative slaughter and nitrogen balance; compare the adjusted models for each technique and estimate the maintenance requirement for pullets. Assays were performed during 14 to 28, 56-70 and 98 to 112 days of age, using 168 pullets. The design was completely randomized with seven treatments and eight replications. Treatments consisted of protein levels ranging from 75 to 435gkg-1 of dry matter. The variables were collected by comparative slaughter and nitrogen ingested and deposited in nitrogen balance technique intake and nitrogen excretion. The intercept of the exponential relationship between ingested and excreted nitrogen was considered a requirement for maintenance. The adjusted models were compared by using the maximum likelihood ratio. The techniques described differently compared the requirement for maintenance of nitrogen. For comparative slaughter requiring maintenance was estimated at 342, 372 and 543mg/kgPC0,67 and for nitrogen balance was 342, 225 and 284mg/kgPC0,67 for the period of 14 to 28, 56-70 and 98 to 112 days of age, respectively.
Resumo:
One of the main objectives of the Spanish and Portuguese-Speaking Group of the International Society for Forensic Genetics (GHEP-ISFG) is to promote and contribute to the development and dissemination of scientific knowledge in the area of forensic genetics. Due to this fact, GHEP-ISFG holds different working commissions that are set up to develop activities in scientific aspects of general interest. One of them, the Mixture Commission of GHEP-ISFG, has organized annually, since 2009, a collaborative exercise on analysis and interpretation of autosomal short tandem repeat (STR) mixture profiles. Until now, three exercises have been organized (GHEP-MIX01, GHEP-MIX02 and GHEP-MIX03), with 32, 24 and 17 participant laboratories respectively. The exercise aims to give a general vision by addressing, through the proposal of mock cases, aspects related to the edition of mixture profiles and the statistical treatment. The main conclusions obtained from these exercises may be summarized as follows. Firstly, the data show an increased tendency of the laboratories toward validation of DNA mixture profiles analysis following international recommendations (ISO/IEC 17025: 2005). Secondly, the majority of discrepancies are mainly encountered in stutters positions (53.4%, 96.0% and 74.9%, respectively for the three editions). On the other hand, the results submitted reveal the importance of performing duplicate analysis by using different kits in order to reduce errors as much as possible. Regarding the statistical aspect (GHEP-MIX02 and 03), all participants employed the likelihood ratio (LR) parameter to evaluate the statistical compatibility and the formulas employed were quite similar. When the hypotheses to evaluate the LR value were locked by the coordinators (GHEP-MIX02) the results revealed a minor number of discrepancies that were mainly due to clerical reasons. However, the GHEP-MIX03 exercise allowed the participants to freely come up with their own hypotheses to calculate the LR value. In this situation the laboratories reported several options to explain the mock cases proposed and therefore significant differences between the final LR values were obtained. Complete information concerning the background of the criminal case is a critical aspect in order to select the adequate hypotheses to calculate the LR value. Although this should be a task for the judicial court to decide, it is important for the expert to account for the different possibilities and scenarios, and also offer this expertise to the judge. In addition, continuing education in the analysis and interpretation of mixture DNA profiles may also be a priority for the vast majority of forensic laboratories. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This is an ecological, analytical and retrospective study comprising the 645 municipalities in the State of Sao Paulo, the scope of which was to determine the relationship between socioeconomic, demographic variables and the model of care in relation to infant mortality rates in the period from 1998 to 2008. The ratio of average annual change for each indicator per stratum coverage was calculated. Infant mortality was analyzed according to the model for repeated measures over time, adjusted for the following correction variables: the city's population, proportion of Family Health Programs (PSFs) deployed, proportion of Growth Acceleration Programs (PACs) deployed, per capita GDP and SPSRI (Sao Paulo social responsibility index). The analysis was performed by generalized linear models, considering the gamma distribution. Multiple comparisons were performed with the likelihood ratio with chi-square approximate distribution, considering a significance level of 5%. There was a decrease in infant mortality over the years (p < 0.05), with no significant difference from 2004 to 2008 (p > 0.05). The proportion of PSFs deployed (p < 0.0001) and per capita GDP (p < 0.0001) were significant in the model. The decline of infant mortality in this period was influenced by the growth of per capita GDP and PSFs.
Resumo:
The study of short implants is relevant to the biomechanics of dental implants, and research on crown increase has implications for the daily clinic. The aim of this study was to analyze the biomechanical interactions of a singular implant-supported prosthesis of different crown heights under vertical and oblique force, using the 3-D finite element method. Six 3-D models were designed with Invesalius 3.0, Rhinoceros 3D 4.0, and Solidworks 2010 software. Each model was constructed with a mandibular segment of bone block, including an implant supporting a screwed metal-ceramic crown. The crown height was set at 10, 12.5, and 15 mm. The applied force was 200 N (axial) and 100 N (oblique). We performed an ANOVA statistical test and Tukey tests; p < 0.05 was considered statistically significant. The increase of crown height did not influence the stress distribution on screw prosthetic (p > 0.05) under axial load. However, crown heights of 12.5 and 15 mm caused statistically significant damage to the stress distribution of screws and to the cortical bone (p <0.001) under oblique load. High crown to implant (C/I) ratio harmed microstrain distribution on bone tissue under axial and oblique loads (p < 0.001). Crown increase was a possible deleterious factor to the screws and to the different regions of bone tissue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)